Development land reliability of a measurement device for flexion force of the first metatarsophalangeal joint

被引:2
|
作者
Swanenburg, J
Stappaerts, KH
Tirez, B
Uebelhart, D
Aufdemkampe, G
机构
[1] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Med Phys, CH-8091 Zurich, Switzerland
[3] Catholic Univ Louvain, Dept Rehabil Sci, B-3000 Louvain, Belgium
[4] Univ Leuven, Dept Phys, Louvain, Belgium
[5] Univ Hosp Leuven, Dept Phys Med & Rehabil, Louvain, Belgium
[6] Polytech Utrecht, Dept Phys Therapy, Utrecht, Netherlands
关键词
hallux; aged; women; strength;
D O I
10.1123/jab.19.3.271
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to present a method for repeated measurement of flexion force of the hallux in the metatarsophalangeal joint. The reliability of this measurement device was also examined. This device is suitable for situations where weight-bearing is contraindicated or when it is not possible for patients to bear load on their toes, such as hallux valgus patients. Since most such patients are female, the participants in this study were 24 healthy female volunteers. Age, weight, height, and leg dominance were determined for each. Muscle strength was measured using a device with a built-in MicroFET dynamometer. The result for the left hallux was ICC(3,1).89 (95 % CI.77-95). The result for the right hallux was ICC(3,1).94 (95% CI.87-97). In the Bland and Altman plots, the reliability again appeared to be sufficient. The Pearson product-moment correlations gave poor results for the association between body weight, height, age, and mean force of the four trails. The test results indicate good reliability of the measurement device as used in this study. The advantage of this testing device is that it makes it easier to standardize measurements as opposed to the MicroFET used as a hand-held dynamometer. Also, patients can be tested in a nonload situation, which makes it possible to test hallux valgus at any time, and therefore it is possible to monitor variations in progression (or regression).
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] MOTION OF THE FIRST METATARSOPHALANGEAL JOINT - RELIABILITY AND VALIDITY OF 4 MEASUREMENT TECHNIQUES
    HOPSON, MM
    MCPOIL, TG
    CORNWALL, MW
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1995, 85 (04): : 198 - 204
  • [2] Reliability and validity of first metatarsophalangeal joint orientation measured with an electromagnetic tracking device
    Umberger, BR
    Nawoczenski, DA
    Baumhauer, JF
    CLINICAL BIOMECHANICS, 1999, 14 (01) : 74 - 76
  • [3] Reliability of metatarsophalangeal and ankle joint torque measurements by an innovative device
    Man, Hok-Sum
    Leung, Aaron Kam-Lun
    Cheung, Jason Tak-Man
    Sterzing, Thorsten
    GAIT & POSTURE, 2016, 48 : 189 - 193
  • [4] Arthrodesis of the first metatarsophalangeal joint using an intraosseous fixation device
    Tytgat, Hannes E.
    Wuite, Sander
    Matricali, Giovanni A.
    ACTA ORTHOPAEDICA BELGICA, 2022, 88 (01): : 135 - 142
  • [5] Structural assessment of pre-flexion in silicone implants for arthroplasty of the first metatarsophalangeal joint
    Mancera Campos, Natali
    Vidal-Lesso, Agustin
    Bayod-Lopez, Javier
    Becerro de Bengoa-Vallejo, Ricardo
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (06) : 909 - 920
  • [6] Intrarater and interrater reliability of the first metatarsophalangeal joint dorsiflexion resistance test
    Moisan, Gabriel
    McBride, Sean
    Isabelle, Pier-Luc
    Chicoine, Dominic
    Walha, Roua
    MUSCULOSKELETAL CARE, 2023, 21 (01) : 102 - 107
  • [7] Development and Reliability of an Intraoperative First Metatarsophalangeal Joint Cartilage Evaluation Tool for Use in Hallux Valgus Surgery
    Smith, Simon E.
    Landorf, Karl B.
    Gilheany, Mark F.
    Menz, Hylton B.
    JOURNAL OF FOOT & ANKLE SURGERY, 2011, 50 (01): : 31 - 36
  • [8] Measurement of the isometric dorsiflexion and plantar flexion force in the ankle joint
    Göpfert, B
    Valderrabano, V
    Hintermann, B
    Wirz, D
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (09): : 282 - 286
  • [9] The effects of restricting the flexion-extension motion of the first metatarsophalangeal joint on human walking gait
    Zhang, Junxia
    Si, Ying
    Zhang, Yan
    Liu, Yefang
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 2577 - 2584
  • [10] Development of an Injury Risk Function for First Metatarsophalangeal Joint Sprains
    Frimenko, Rebecca E.
    Lievers, W. Brent
    Riley, Patrick O.
    Park, Joseph S.
    Hogan, Macalus V.
    Crandall, Jeff R.
    Kent, Richard W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (11): : 2144 - 2150