Development land reliability of a measurement device for flexion force of the first metatarsophalangeal joint

被引:2
|
作者
Swanenburg, J
Stappaerts, KH
Tirez, B
Uebelhart, D
Aufdemkampe, G
机构
[1] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Med Phys, CH-8091 Zurich, Switzerland
[3] Catholic Univ Louvain, Dept Rehabil Sci, B-3000 Louvain, Belgium
[4] Univ Leuven, Dept Phys, Louvain, Belgium
[5] Univ Hosp Leuven, Dept Phys Med & Rehabil, Louvain, Belgium
[6] Polytech Utrecht, Dept Phys Therapy, Utrecht, Netherlands
关键词
hallux; aged; women; strength;
D O I
10.1123/jab.19.3.271
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to present a method for repeated measurement of flexion force of the hallux in the metatarsophalangeal joint. The reliability of this measurement device was also examined. This device is suitable for situations where weight-bearing is contraindicated or when it is not possible for patients to bear load on their toes, such as hallux valgus patients. Since most such patients are female, the participants in this study were 24 healthy female volunteers. Age, weight, height, and leg dominance were determined for each. Muscle strength was measured using a device with a built-in MicroFET dynamometer. The result for the left hallux was ICC(3,1).89 (95 % CI.77-95). The result for the right hallux was ICC(3,1).94 (95% CI.87-97). In the Bland and Altman plots, the reliability again appeared to be sufficient. The Pearson product-moment correlations gave poor results for the association between body weight, height, age, and mean force of the four trails. The test results indicate good reliability of the measurement device as used in this study. The advantage of this testing device is that it makes it easier to standardize measurements as opposed to the MicroFET used as a hand-held dynamometer. Also, patients can be tested in a nonload situation, which makes it possible to test hallux valgus at any time, and therefore it is possible to monitor variations in progression (or regression).
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [41] The Design, Development, and Reliability Testing of a New Innovative Device to Measure Ankle Joint Dorsiflexion
    Charles, James
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2016, 106 (05) : 338 - 343
  • [42] Development and application of friction force measurement device for compression-shear tests
    Liu L.
    Pan P.
    Wang H.
    Feng P.
    Zhao M.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (06): : 133 - 139
  • [43] DEVELOPMENT AND VALIDATION OF A HOMEMADE DEVICE FOR THE MEASUREMENT OF URETERAL ACCESS SHEATH INSERTION FORCE
    Koo, Kyo Chul
    Yoon, Joon Ho
    Park, No-Cheol
    Lee, Kwang Suk
    Kim, Do Kyung
    Kim, Jong Chan
    Kang, Sung Ku
    Jeong, Jae Yong
    Kim, Jong Won
    Lee, Jongsoo
    Hong, Chang Hee
    Chung, Byung Ha
    JOURNAL OF UROLOGY, 2017, 197 (04): : E812 - E812
  • [44] Development of a Wearable Plantar Force Measurement Device for Gait Analysis in Remote Conditions
    Hamid, Rawnak
    Wijesundara, Suharshani
    McMillan, Lachlan
    Scott, David
    Redoute, Jean-Michel
    Ebeling, Peter R.
    Yuce, Mehmet Rasit
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 139 - 142
  • [45] Development of a Force Measurement Device for the Tele-Operative Catheter Operating System
    Li, Hengrui
    Guo, Shuxiang
    Guo, Jin
    Yin, Xuanchun
    Wang, Yu
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 425 - 430
  • [46] Development of an Objective Portable Measurement Device for Spinal Joint Accessory Motion Testing
    Wu, Hsiao-Kuan
    Lai, Hung-Jen
    Teng, Ting
    Yu, Chung-Huang
    SENSORS, 2020, 20 (01)
  • [47] Reliability of a semiautomated computer-assisted measurement of the joint space width (JS']JSW) of medial tibiofemoral compartment in metatarsophalangeal (MTP) knee radiographs
    Hernández-Cruz, B
    Navarro-Sarabia, F
    Toyos, J
    Mendoza, D
    Coronel, P
    Gimeno, M
    Ramos, M
    ANNALS OF THE RHEUMATIC DISEASES, 2004, 63 : 525 - 525
  • [48] Reliability of Maximal Strength and Peak Rate of Force Development in a Portable Nordic Hamstrings Exercise Device
    Costa, Julio A.
    Spyrou, Konstantinos
    Sancho, Antonio
    Reis, Joana F.
    Brito, Joao
    SENSORS, 2023, 23 (12)
  • [49] Development and Intertester Reliability of a Novel Device to Measure Nonweightbearing Ankle Joint Dorsiflexion Range of Motion
    Charles, James A.
    Diot, Romain
    Houari, Camilia
    Chuter, Vivienne
    Pillu, Michel
    Mcdonough, Daniel
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2023, 113 (01)
  • [50] Development of multi-axial micro force measurement method for electronic device assembly
    Choi, Byung June
    Ryu, Sang Heon
    Ha, Seung Hwa
    Phung, Tri Cong
    Koo, Ja Choon
    Park, Sangdeok
    Lee, Sangmoo
    Choi, Hyouk Ryeol
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 5742 - 5746