Reliability and validity of first metatarsophalangeal joint orientation measured with an electromagnetic tracking device

被引:42
|
作者
Umberger, BR
Nawoczenski, DA
Baumhauer, JF
机构
[1] Univ Rochester, Ithaca Coll, Med Ctr, Dept Phys Therapy, Rochester, NY 14623 USA
[2] Univ Rochester, Med Ctr, Dept Orthopaed, Rochester, NY 14642 USA
关键词
hallux; skeletal kinematics; cadaver; anatomical coordinate system; Flock of Birds;
D O I
10.1016/S0268-0033(98)00052-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To establish the reliability and validity of measurements of sagittal plane orientation of the first metatarsophalangeal joint using the Flock of Birds(TM) electromagnetic tracking device. Design. Different joint orientations were reproduced on cadaver specimens in a specially designed jig with skin and skeletal application of the sensors. Background. The Flock of Birds(TM) provides a means for quantifying first metatarsophalangeal joint motion, however, the reliability and validity of such an application has not been determined. Methods. Joint orientation was measured in five cadaver feet with skin and skeletal sensor application. A specially designed jig allowed simulation of clinical tests of range of motion. Sagittal plane orientation was determined From 3-D, anatomically-based, reference frames embedded in the first metatarsal and proximal hallux. Results. Reliability of all measurements was high for skin and skeletal sensor application. There were no significant differences in joint orientation between either technique for any of the simulated motion tests. Conclusions. The Flock of Birds(TM) provides reliable and valid measures of first metatarsophalangeal joint orientation with the sensors applied to the skin over the first metatarsal and proximal hallux.
引用
收藏
页码:74 / 76
页数:3
相关论文
共 38 条
  • [1] MOTION OF THE FIRST METATARSOPHALANGEAL JOINT - RELIABILITY AND VALIDITY OF 4 MEASUREMENT TECHNIQUES
    HOPSON, MM
    MCPOIL, TG
    CORNWALL, MW
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1995, 85 (04): : 198 - 204
  • [2] An enhanced protocol to reduce error in electromagnetic tracking of first metatarsophalangeal joint motions
    Longworth, R
    Chockalingam, N
    Redmond, AC
    GAIT & POSTURE, 2006, 23 (03) : 391 - 394
  • [3] Development land reliability of a measurement device for flexion force of the first metatarsophalangeal joint
    Swanenburg, J
    Stappaerts, KH
    Tirez, B
    Uebelhart, D
    Aufdemkampe, G
    JOURNAL OF APPLIED BIOMECHANICS, 2003, 19 (03) : 271 - 278
  • [4] Reliability of metatarsophalangeal and ankle joint torque measurements by an innovative device
    Man, Hok-Sum
    Leung, Aaron Kam-Lun
    Cheung, Jason Tak-Man
    Sterzing, Thorsten
    GAIT & POSTURE, 2016, 48 : 189 - 193
  • [5] Validity and reliability of a player-tracking device to identify movement orientation in team sports
    Tan, Justin H. Y.
    Polglaze, Ted
    Peeling, Peter
    INTERNATIONAL JOURNAL OF PERFORMANCE ANALYSIS IN SPORT, 2021, 21 (05) : 790 - 803
  • [6] Arthrodesis of the first metatarsophalangeal joint using an intraosseous fixation device
    Tytgat, Hannes E.
    Wuite, Sander
    Matricali, Giovanni A.
    ACTA ORTHOPAEDICA BELGICA, 2022, 88 (01): : 135 - 142
  • [7] Intrarater and interrater reliability of the first metatarsophalangeal joint dorsiflexion resistance test
    Moisan, Gabriel
    McBride, Sean
    Isabelle, Pier-Luc
    Chicoine, Dominic
    Walha, Roua
    MUSCULOSKELETAL CARE, 2023, 21 (01) : 102 - 107
  • [8] The reliability and validity of a first ray measurement device
    Glasoe, WM
    Yack, HJ
    Saltzman, CL
    FOOT & ANKLE INTERNATIONAL, 2000, 21 (03) : 240 - 246
  • [9] Reliability and diagnostic validity of a joint vibration analysis device
    Sonia Sharma
    Heidi C. Crow
    Krishnan Kartha
    W. D. McCall
    Yoly M. Gonzalez
    BMC Oral Health, 17
  • [10] Reliability and diagnostic validity of a joint vibration analysis device
    Sharma, Sonia
    Crow, Heidi C.
    Kartha, Krishnan
    McCall, W. D., Jr.
    Gonzalez, Yoly M.
    BMC ORAL HEALTH, 2017, 17