Investigations of a flat-panel detector for quality assurance measurements in ion beam therapy

被引:15
|
作者
Hartmann, Bernadette [1 ,2 ]
Telsemeyer, Julia [1 ,2 ]
Huber, Lucas [1 ]
Ackermann, Benjamin [3 ]
Jaekel, Oliver [1 ,2 ,3 ]
Martisikova, Maria [1 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Univ Klinikum Heidelberg, Klin Radioonkol & Strahlentherapie, D-69120 Heidelberg, Germany
[3] Univ Klinikum Heidelberg, HIT, D-69120 Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 01期
关键词
RADIOTHERAPY; MODEL;
D O I
10.1088/0031-9155/57/1/51
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Increased accuracy in radiation delivery to a patient provided by scanning particle beams leads to high demands on quality assurance (QA). To meet the requirements, an extensive quality assurance programme has been implemented at the Heidelberg Ion Beam Therapy Center. Currently, high-resolution radiographic films are used for beam spot position measurements and homogeneity measurements for scanned fields. However, given that using this film type is time and equipment demanding, considerations have been made to replace the radiographic films in QA by another appropriate device. In this study, the suitability of the flat-panel detector RID 256 L based on amorphous silicon was investigated as an alternative method. The currently used radiographic films were taken as a reference. Investigations were carried out for proton and carbon ion beams. The detectors were irradiated simultaneously to allow for a direct comparison. The beam parameters (e. g. energy, focus, position) currently used in the daily QA procedures were applied. Evaluation of the measurements was performed using newly implemented automatic routines. The results for the flat-panel detector were compared to the standard radiographic films. Additionally, a field with intentionally decreased homogeneity was applied to test the detector's sensitivities toward possible incorrect scan parameters. For the beam position analyses, the flat-panel detector results showed good agreement with radiographic films. For both detector types, deviations between measured and planned spot distances were found to be below 1% (1 mm). In homogeneously irradiated fields, the flat-panel detector showed a better dose response homogeneity than the currently used radiographic film. Furthermore, the flat-panel detector is sensitive to field irregularities. The flat-panel detector was found to be an adequate replacement for the radiographic film in QA measurements. In addition, it saves time and equipment because no post-exposure treatment and no developer and darkroom facilities are needed.
引用
收藏
页码:51 / 68
页数:18
相关论文
共 50 条
  • [21] Instrumentation Noise Equivalent Exposure (INEE) for Routine Quality Assurance: INEE Measurements On a Clinical Flat Panel Detector
    Szczykutowicz, T.
    Kuhls-Gilcrist, A.
    Bednarek, D.
    Rudin, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [22] Dose and image quality of flat-panel detector volume computed tomography for sinus imaging
    Alspaugh, J.
    Christodoulou, E.
    Goodsitt, M.
    Stayman, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2634 - 2634
  • [23] Clinical translation of a new flat-panel detector for beam's-eye-view imaging
    Harris, T. C.
    Seco, J.
    Ferguson, D.
    Lehmann, M.
    Huber, P.
    Shi, M.
    Jacobson, M.
    Lozano, I. Valencia
    Myronakis, M.
    Baturin, P.
    Fueglistaller, R.
    Morf, D.
    Berbeco, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22):
  • [24] Experimental verification of ion range calculation in a treatment planning system using a flat-panel detector
    Telsemeyer, Julia
    Ackermann, Benjamin
    Ecker, Swantje
    Jaekel, Oliver
    Martisikova, Maria
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3737 - 3747
  • [25] Se-based flat-panel detector for screening mammography
    Polischuk, B
    Savard, S
    Loustauneau, V
    Hansroul, M
    Cadieux, S
    Vaqué, A
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 582 - 589
  • [26] A gain correction method based on threshold for flat-panel detector
    Xiao, Da-Yu
    Cai, Peng-Fei
    Li, Hong
    Kang, Yan
    [J]. Dongbei Daxue Xuebao/Journal of Northeastern University, 2014, 35 (02): : 208 - 211
  • [27] A LabVIEW driver for X-ray flat-panel detector
    Department of Biomedical Engineering, Huazhong University of Science and Technology, Ministry of Education, Wuhan 430074, China
    [J]. J X Ray Sci Technol, 2008, 4 (261-268):
  • [28] Imaging performance of a direct digital flat-panel radiographic detector
    Kengyelics, SM
    Davies, AG
    Launders, JH
    Cowen, AR
    Richardson, DL
    Wilson, P
    [J]. RADIOLOGY, 1998, 209P : 358 - 358
  • [29] A LabVIEW driver for X-ray flat-panel detector
    Bi, Kun
    Liu, Qian
    Lv, Xiaohua
    Luo, Qingming
    Zeng, Shaoqun
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (04) : 261 - 268
  • [30] Experimental in vitro study to evaluate a flat-panel detector system
    Meier, S
    Mildenberger, P
    Oberholzer, K
    Krummenauer, F
    Thelen, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06): : 875 - 879