Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning

被引:8
|
作者
Winterhalter, Carla [1 ,2 ]
Aitkenhead, Adam [3 ,4 ]
Oxley, David [1 ]
Richardson, Jenny [3 ]
Weber, Damien C. [1 ,5 ,6 ]
MacKay, Ranald, I [3 ,4 ]
Lomax, Antony J. [1 ,2 ]
Safai, Sairos [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester, Lancs, England
[4] Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[5] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
[6] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
来源
BRITISH JOURNAL OF RADIOLOGY | 2020年 / 93卷 / 1107期
关键词
DOSE CALCULATION; RANGE UNCERTAINTIES; SIMULATIONS; THERAPY; SETTINGS; TOOLKIT; IMPACT; CODE;
D O I
10.1259/bjr.20190919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Monte Carlo (MC) simulations substantially improve the accuracy of predicted doses. This study aims to determine and quantify the uncertainties of setting up such a MC system. Methods: Doses simulated with two Geant4-based MC calculation codes, but independently tuned to the same beam data, have been compared. Different methods of MC modelling of a pre-absorber have been employed, either modifying the beam source parameters (descriptive) or adding the pre-absorber as a physical component (physical). Results: After the independent beam modelling of both systems in water (resulting in excellent range agreement) range differences of up to 3.6/4.8 mm (1.5% of total range) in bone/brain-like tissues were found, which resulted from the use of different mean water ionisation potentials during the energy tuning process. When repeating using a common definition of water, ranges in bone/brain agreed within 0.1 mm and gamma-analysis (global 1%,1mm) showed excellent agreement (>93%) for all patient fields. However, due to a lack of modelling of proton fluence loss in the descriptive pre-absorber, differences of 7% in absolute dose between the pre-absorber definitions were found. Conclusion: This study quantifies the influence of using different water ionisation potentials during the MC beam modelling process. Furthermore, when using a descriptive pre-absorber model, additional Faraday cup or ionisation chamber measurements with pre-absorber are necessary. Advances in knowledge: This is the first study quantifying the uncertainties caused by the MC beam modelling process for proton pencil beam scanning, and a more detailed beam modelling process for MC simulations is proposed to minimise the influence of critical parameters.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Log file based Monte Carlo calculations for proton pencil beam scanning therapy
    Winterhalter, Carla
    Meier, Gabriel
    Oxley, David
    Weber, Damien C.
    Lomax, Antony J.
    Safai, Sairos
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [2] Monte Carlo model of a gantry for proton pencil beam scanning
    Winterhalter, Carla
    Safai, Sairos
    Grassberger, Clemens
    Oxley, David
    Weber, Damien C.
    Lomax, Tony
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 837 - 837
  • [3] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    [J]. MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [5] Criteria of spot asymmetry in proton radiotherapy pencil beam scanning - a Monte Carlo study
    Klodowska, M.
    Gajewski, J.
    Skowronska, K.
    Olko, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S57 - S58
  • [6] Monte Carlo modeling of non-isocentric proton pencil beam scanning treatments
    Elia, A.
    Grevillot, L.
    Carlino, A.
    Boehlen, T.
    Fuchs, H.
    Stock, M.
    Sarrut, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S806 - S807
  • [7] The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation
    Wang, Z.
    Gao, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 296 - 296
  • [8] Clinical applications of a Monte Carlo tool of a proton pencil beam scanning delivery system
    Fracchiolla, F.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S379 - S380
  • [9] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [10] Validation and Application of a Commercial Proton Monte Carlo Pencil Beam Scanning Treatment Planning System
    Huang, S.
    Maslowski, A.
    Hiltunen, P.
    Lin, L.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E589 - E589