Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning

被引:9
|
作者
Winterhalter, Carla [1 ,2 ]
Aitkenhead, Adam [3 ,4 ]
Oxley, David [1 ]
Richardson, Jenny [3 ]
Weber, Damien C. [1 ,5 ,6 ]
MacKay, Ranald, I [3 ,4 ]
Lomax, Antony J. [1 ,2 ]
Safai, Sairos [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester, Lancs, England
[4] Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[5] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
[6] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
来源
BRITISH JOURNAL OF RADIOLOGY | 2020年 / 93卷 / 1107期
关键词
DOSE CALCULATION; RANGE UNCERTAINTIES; SIMULATIONS; THERAPY; SETTINGS; TOOLKIT; IMPACT; CODE;
D O I
10.1259/bjr.20190919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Monte Carlo (MC) simulations substantially improve the accuracy of predicted doses. This study aims to determine and quantify the uncertainties of setting up such a MC system. Methods: Doses simulated with two Geant4-based MC calculation codes, but independently tuned to the same beam data, have been compared. Different methods of MC modelling of a pre-absorber have been employed, either modifying the beam source parameters (descriptive) or adding the pre-absorber as a physical component (physical). Results: After the independent beam modelling of both systems in water (resulting in excellent range agreement) range differences of up to 3.6/4.8 mm (1.5% of total range) in bone/brain-like tissues were found, which resulted from the use of different mean water ionisation potentials during the energy tuning process. When repeating using a common definition of water, ranges in bone/brain agreed within 0.1 mm and gamma-analysis (global 1%,1mm) showed excellent agreement (>93%) for all patient fields. However, due to a lack of modelling of proton fluence loss in the descriptive pre-absorber, differences of 7% in absolute dose between the pre-absorber definitions were found. Conclusion: This study quantifies the influence of using different water ionisation potentials during the MC beam modelling process. Furthermore, when using a descriptive pre-absorber model, additional Faraday cup or ionisation chamber measurements with pre-absorber are necessary. Advances in knowledge: This is the first study quantifying the uncertainties caused by the MC beam modelling process for proton pencil beam scanning, and a more detailed beam modelling process for MC simulations is proposed to minimise the influence of critical parameters.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A Monte Carlo Study on Fetal Dose from Craniospinal Irradiation with Proton Pencil Beam Scanning Treatment
    Yeom, Y.
    Griffin, K.
    Mille, M.
    Lee, C.
    O'Reilly, S.
    Dong, L.
    Jung, J.
    Lee, C.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [22] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    [J]. MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [23] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    [J]. MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [24] Monte Carlo simulation tool for commissioning measurements corrections of a proton pencil beam scanning (PBS) mode
    Fracchiolla, F.
    Lorentini, S.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S13 - S14
  • [25] Dosimetric data for broad beam, pencil beam and Monte Carlo models of clinical proton beams
    Mazal, A
    Kooy, H
    Nauraye, C
    Schaffner, B
    Rosenthal, S
    Kollipara, S
    Paganetti, H
    Ferrand, R
    Rosenwald, JC
    Chen, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S321 - S321
  • [26] Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy
    Huang, Sheng
    Souris, Kevin
    Li, Siyang
    Kang, Minglei
    Montero, Ana Maria Barragan
    Janssens, Guillaume
    Lin, Alexander
    Garver, Elizabeth
    Ainsley, Christopher
    Taylor, Paige
    Xiao, Ying
    Lin, Liyong
    [J]. MEDICAL PHYSICS, 2018, 45 (12) : 5631 - 5642
  • [27] A Comparison Between Pencil Beam Versus Monte Carlo Calculations in Arc Therapy
    Shin, H.
    Jung, J.
    Kim, M.
    Kay, C.
    Son, S.
    Kang, Y.
    Choi, B.
    Jang, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S710 - S710
  • [28] Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Schwarz, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8601 - 8619
  • [29] Development and Validation of a TOPAS Monte Carlo Model of a Dynamic Collimation System for Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Rana, S.
    Gutierrez, A.
    Hill, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [30] 'End to end' validation of a Monte Carlo code for independent dose calculation in a proton pencil beam scanning system
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Farace, P.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S78 - S79