Clinical application of a flat-panel x-ray detector based on amorphous silicon technology:: Image quality and potential for radiation dose reduction in skeletal radiography

被引:58
|
作者
Strotzer, M
Gmeinwieser, J
Völk, M
Fründ, R
Seitz, J
Manke, C
Albrich, H
Feuerbach, S
机构
[1] Univ Hosp Regensburg, Dept Diagnost Radiol, D-93042 Regensburg, Germany
[2] Klinikum Furth, D-90766 Furth, Germany
关键词
D O I
10.2214/ajr.171.1.9648757
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS. One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 mu Gy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS. Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION. The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 50 条
  • [11] Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    Dobbins, JT
    Samei, E
    Chotas, HG
    Warp, RJ
    Baydush, AH
    Floyd, CE
    Ravin, CE
    RADIOLOGY, 2003, 226 (01) : 221 - 230
  • [12] Prospects for x-ray exposure reduction using digital radiography with a flat-panel detector
    Okusako, K
    Hatagawa, M
    Kishimoto, K
    Tanaka, K
    Kudo, H
    Yamada, R
    RADIOLOGY, 2001, 221 : 158 - 158
  • [13] Routine skeleton radiography using a flat-panel detector:: Image quality and clinical acceptance at 50% dose reduction
    Völk, M
    Paetzel, C
    Angele, P
    Seitz, J
    Füchtmeier, B
    Hente, R
    Feuerbach, S
    Strotzer, M
    INVESTIGATIVE RADIOLOGY, 2003, 38 (04) : 230 - 235
  • [14] Chest radiography with a flat-panel detector:: Image quality with dose reduction after copper filtration
    Hamer, OW
    Sirlin, CB
    Strotzer, M
    Borisch, I
    Zorger, N
    Feuerbach, S
    Völk, M
    RADIOLOGY, 2005, 237 (02) : 691 - 700
  • [15] Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography -: Effect of dose reduction on the detectability of cortical bone defects and fractures
    Strotzer, M
    Gmeinwieser, J
    Spahn, M
    Völk, M
    Fründ, R
    Seitz, J
    Spies, V
    Alexander, J
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1998, 33 (01) : 33 - 38
  • [16] Routine chest radiography using a flat-panel detector:: Image quality at standard detector dose and 33% dose reduction
    Strotzer, M
    Völk, M
    Fründ, R
    Hamer, O
    Zorger, N
    Feuerbach, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (01) : 169 - 171
  • [17] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [18] Detection of simulated chest lesions with normal and reduced radiation dose -: Comparison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon
    Strotzer, M
    Gmeinwieser, JK
    Völk, M
    Fründ, R
    Seitz, J
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1998, 33 (02) : 98 - 103
  • [19] Performance of an amorphous silicon flat panel X-ray imaging detector for general radiography
    Granfors, PR
    Aufrichtig, R
    RADIOLOGY, 1999, 213P : 234 - 234
  • [20] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Hennigs, SP
    Garmer, M
    Jaeger, HJ
    Classen, R
    Jacobs, A
    Gissler, HM
    Christmann, A
    Mathias, K
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1688 - 1696