Clinical application of a flat-panel x-ray detector based on amorphous silicon technology:: Image quality and potential for radiation dose reduction in skeletal radiography

被引:58
|
作者
Strotzer, M
Gmeinwieser, J
Völk, M
Fründ, R
Seitz, J
Manke, C
Albrich, H
Feuerbach, S
机构
[1] Univ Hosp Regensburg, Dept Diagnost Radiol, D-93042 Regensburg, Germany
[2] Klinikum Furth, D-90766 Furth, Germany
关键词
D O I
10.2214/ajr.171.1.9648757
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS. One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 mu Gy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS. Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION. The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 50 条
  • [21] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Svenja P. Hennigs
    Marietta Garmer
    Horst J. Jaeger
    Reinhard Classen
    Andreas Jacobs
    Hans M. Gissler
    Andreas Christmann
    Klaus Mathias
    European Radiology, 2001, 11 : 1688 - 1696
  • [22] Amorphous silicon, flat-panel, X-ray detector:: Reliability of digital image fusion regarding angle and distance measurements in long-leg radiography
    Hamer, OW
    Strotzer, M
    Zorger, N
    Paetzel, C
    Lerch, K
    Feuerbach, SA
    Völk, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (05) : 271 - 276
  • [23] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [24] Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier
    Ducote, Justin L.
    Xu, Tong
    Molloi, Sabee
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 183 - 196
  • [25] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Kim, JY
    Park, JK
    Choi, JY
    Cha, BY
    Kang, SS
    An, SH
    Nam, SH
    Choi, HK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4048 - 4052
  • [26] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270
  • [27] Image quality and radiation dose on digital chest imaging: Comparison of amorphous silicon and amorphous selenium flat-panel systems
    Bacher, Klaus
    Smeets, Peter
    Vereecken, Ludo
    De Hauwere, An
    Duyck, Philippe
    De Man, Robert
    Verstraete, Koenraad
    Thierens, Hubert
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 630 - 637
  • [28] Flat-panel X-ray detector based on amorphous silicon versus asymmetric screen-film system: Phantom study of dose reduction and depiction of simulated findings
    Rapp-Bernhardt, U
    Roehl, FW
    Gibbs, RC
    Schmidl, H
    Krause, UW
    Bernhardt, TM
    RADIOLOGY, 2003, 227 (02) : 484 - 492
  • [29] Clinical comparative study with a large-area amorphous silicon flat-panel detector: Image quality and visibility of anatomic structures on chest radiography
    Fink, C
    Hallscheidt, PJ
    Noeldge, G
    Kampschulte, A
    Radeleff, B
    Hosch, WP
    Kauffmann, GW
    Hansmann, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) : 481 - 486
  • [30] Digital flat-panel X-ray technology based on cesium iodide and amorphous silicon:: experimental studies and preliminary clinical results.
    Strotzer, M
    Gmeinwieser, J
    Völk, M
    Fründ, R
    Feuerbach, S
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (01): : 66 - 72