Clinical application of a flat-panel x-ray detector based on amorphous silicon technology:: Image quality and potential for radiation dose reduction in skeletal radiography

被引:58
|
作者
Strotzer, M
Gmeinwieser, J
Völk, M
Fründ, R
Seitz, J
Manke, C
Albrich, H
Feuerbach, S
机构
[1] Univ Hosp Regensburg, Dept Diagnost Radiol, D-93042 Regensburg, Germany
[2] Klinikum Furth, D-90766 Furth, Germany
关键词
D O I
10.2214/ajr.171.1.9648757
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS. One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 mu Gy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS. Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION. The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 50 条
  • [1] Clinical application and experimental evaluation of a flat-panel x-ray detector based on amorphous silicon (a-Si): Image quality and potential of dose reduction in skeletal radiography
    Strotzer, M
    Gmeinwieser, JK
    Voelk, M
    Fruend, R
    Seitz, JM
    Spies, V
    RADIOLOGY, 1997, 205 : 1501 - 1501
  • [2] Radiation dose reduction in chest radiography using a flat-panel amorphous silicon detector
    Hosch, WP
    Fink, C
    Radeleff, B
    Kampschulte, A
    Kauffmann, GW
    Hansmann, J
    CLINICAL RADIOLOGY, 2002, 57 (10) : 902 - 907
  • [3] Flat-panel X-ray detector using amorphous silicon technology - Reduced radiation dose for the detection of foreign bodies
    Volk, M
    Strotzer, M
    Gmeinwieser, J
    Alexander, J
    Frund, R
    Seitz, J
    Manke, C
    Spahn, M
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1997, 32 (07) : 373 - 377
  • [4] Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom study
    Geijer, H
    Beckman, KW
    Andersson, T
    Persliden, J
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1704 - 1709
  • [5] Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom study
    Håkan Geijer
    Karl-Wilhelm Beckman
    Torbjörn Andersson
    Jan Persliden
    European Radiology, 2001, 11 : 1704 - 1709
  • [6] Reducing the radiation dose during excretory urography:: Flat-panel silicon X-ray detector versus computed radiography
    Zähringer, M
    Hesselmann, V
    Schulte, O
    Kamm, KF
    Braun, W
    Haupt, G
    Krug, B
    Lackner, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 931 - 937
  • [7] Routine chest radiography with a flat-panel detector: Image quality with standard dose and dose reduction
    Strotzer, M
    Voelk, M
    Fruend, R
    Hamer, O
    Zorger, N
    Feuerbach, SG
    RADIOLOGY, 2001, 221 : 354 - 354
  • [8] Flat-panel X-ray detector using amorphous silicon technology (FD): Reduced radiation dose for the detection of foreign bodies (FB)
    Voelk, M
    Strotzer, M
    Gmeinwieser, JK
    Alexander, J
    Fruend, R
    Seitz, JM
    RADIOLOGY, 1997, 205 : 110 - 110
  • [9] Characterization of a flat-panel amorphous silicon detector for X-ray computed tomography
    Lee, H.-R.
    Ellingson, W.
    Journal of X-Ray Science and Technology, 2001, 9 (01) : 43 - 53
  • [10] Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    Spahn, M
    Strotzer, M
    Völk, M
    Böhm, S
    Geiger, B
    Hahm, G
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 2000, 35 (04) : 260 - 266