Comparison between capnodynamic and thermodilution method for cardiac output monitoring during major abdominal surgery An observational study

被引:8
|
作者
Sigmundsson, Thorir S. [1 ,2 ]
Ohman, Tomas [1 ,2 ]
Hallback, Magnus [3 ]
Suarez-Sipmann, Fernando [4 ,5 ,6 ]
Wallin, Mats [2 ,3 ]
Oldner, Anders [1 ,2 ]
Hallsjo-Sander, Caroline [1 ,2 ]
Bjorne, Hakan [1 ,2 ]
机构
[1] Karolinska Univ Hosp, Perioperat Med & Intens Care, SE-17176 Solna, Sweden
[2] Karolinska Inst, Dept Physiol & Pharmacol, Stockholm, Sweden
[3] Maquet Crit Care AB, Solna, Sweden
[4] Hosp Univ La Princesa, Dept Intens Care, Madrid, Spain
[5] Uppsala Univ, Dept Surg Sci, Sect Anaesthesiol & Crit Care, Hedenstiemas Lab, Uppsala, Sweden
[6] Inst Salud Carlos III, GIBER Eniermedades Respiratorias, Madrid, Spain
关键词
PULMONARY BLOOD-FLOW; FLUID THERAPY; METAANALYSIS; PRECISION; ACCURACY; PERFORMANCE; AGREEMENT; OUTCOMES; ABILITY; RISK;
D O I
10.1097/EJA.0000000000001566
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND Cardiac output (CO) monitoring is the basis of goal-directed treatment for major abdominal surgery. A capnodynamic method estimating cardiac output (COEPBF) by continuously calculating nonshunted pulmonary blood flow has previously shown good agreement and trending ability when evaluated in mechanically ventilated pigs. OBJECTIVES To compare the performance of the capnodynamic method of CO monitoring with transpulmonary thermodilution (COTPTD) in patients undergoing major abdominal surgery. DESIGN Prospective, observational, method comparison study. Simultaneous measurements of COEPBF and COTPTD were performed before incision at baseline and before and after increased (+10 cmH(2)O) positive end-expiratory pressure (PEEP), activation of epidural anaesthesia and intra-operative events of hypovolemia and low CO. The first 25 patients were ventilated with PEEP5 cmH(2)O (PEEN, while in the last 10 patients, lung recruitment followed by individual PEEP adjustment (PEEPadi) was performed before protocol start. SETTING Karolinska University Hospital, Stockholm, Sweden. PATIENTS In total, 35 patients (>18 years) scheduled for major abdominal surgery with advanced hemodynamic monitoring were included in the study. MAIN OUTCOME MEASURES AND ANALYSIS Agreement and trending ability between COEPBF and COTPTD at different clinical moments were analysed with Bland-Altman and four quadrant plots. RESULTS In total, 322 paired values, 227 in PEEP5 and 95 in PEEPadj were analysed. Respectively, the mean COEPBF and COTPTD were 4.5 +/- 1.0 and 4.8 +/- 1.1 in the PEEP5 group and 4.9 +/- 1.2 and 5.0 +/- 1.0 l min(-1) in the PEEPadj group. Mean bias (levels of agreement) and percentage error (PE) were -0.2 (-2.2 to 1.7) l min(-1) and 41% for the PEEP5 group and -0.1 (-1.7 to 1.5) l min(-1) and 31% in the PEEP(adj )group. Concordance rates during changes in COEPBF and COTPTD were 92% in the PEEP5 group and 90% in the PEEPadj group. CONCLUSION COEPBF provides continuous noninvasive CO estimation with acceptable performance, which improved after lung recruitment and PEEP adjustment, although not interchangeable with COTPTD. This method may become a tool for continuous intra-operative CO monitoring during general anaesthesia in the future.
引用
收藏
页码:1242 / 1252
页数:11
相关论文
共 50 条
  • [31] Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: Evaluation of a second-generation bioimpedance device
    Spiess, BD
    Patel, MA
    Soltow, LO
    Wright, IH
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (05) : 567 - 573
  • [32] Comparison of arterial pressure cardiac output monitoring with transpulmonary thermodilution in septic patients
    Boettger, Simon-Friedrich
    Pavlovic, Dragan
    Gruendling, Matthias
    Wendt, Michael
    Hung, Orlando
    Henzler, Dietrich
    Kern, Hartmut Richard
    Lehmann, Christian
    MEDICAL SCIENCE MONITOR, 2010, 16 (03): : PR1 - PR7
  • [33] COMPARISON BETWEEN PRESSURE RECORDING ANALYTICAL METHOD AND THERMODILUTION METHOD TO MEASURE CARDIAC OUTPUT IN AN INFANT ANIMAL MODEL
    Lopez, J.
    Urban, J.
    Gonzalez, R.
    Solana, M. J.
    Lopez-Herce, J.
    INTENSIVE CARE MEDICINE, 2013, 39 : S44 - S44
  • [34] Measuring cardiac output during cardiac catheterization: Marked differences between direct fick cardiac output and thermodilution
    Zahn, R
    Thoma, S
    Gitt, AK
    Lotter, R
    Seidl, K
    Zander, M
    Senges, J
    HERZ KREISLAUF, 1996, 28 (7-8): : 232 - 235
  • [35] The Ability of esCCO™ and ECOM™ Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method
    Thonnerieux, Magalie
    Alexander, Brenton
    Binet, Catherine
    Obadia, Jean-Francois
    Bastien, Olivier
    Desebbe, Olivier
    ANESTHESIA AND ANALGESIA, 2015, 121 (02): : 383 - 391
  • [36] Comparison between pressure-recording analytical method (PRAM) and femoral arterial thermodilution method (FATD) cardiac output monitoring in an infant animal model of cardiac arrest
    Urbano J.
    López J.
    González R.
    Fernández S.N.
    Solana M.J.
    Toledo B.
    Carrillo Á.
    López-Herce J.
    Intensive Care Medicine Experimental, 4 (1)
  • [37] Noninvasive cardiac output monitoring during anaesthesia and surgery in young children using electrical cardiometry: an observational study
    Falciola, Veronique
    Donath, Susan M.
    Roden, Emilie
    Davidson, Andrew
    Vutskits, Laszlo
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 128 (03) : E235 - E238
  • [38] Reproducibility of thermodilution cardiac output determination in critically ill patients: Comparison between bolus and continuous method
    LeTulzo, Y
    Belghith, M
    Seguin, P
    DallAva, J
    Monchi, M
    Thomas, R
    Dhainaut, JF
    JOURNAL OF CLINICAL MONITORING, 1996, 12 (05): : 379 - 385
  • [39] The effect of haemodynamic and peripheral vascular variability on cardiac output monitoring: thermodilution and non-invasive pulse contour cardiac output during cardiothoracic surgery
    Truijen, J.
    Westerhof, B. E.
    Kim, Y-S.
    Stok, W. J.
    de Mol, B. A.
    Preckel, B.
    Hollmann, M. W.
    van Lieshout, J. J.
    ANAESTHESIA, 2018, 73 (12) : 1489 - 1499
  • [40] Comparison between continuous noninvasive estimated cardiac output by pulse wave transit time and thermodilution method
    Mehta, Yatin
    ANNALS OF CARDIAC ANAESTHESIA, 2014, 17 (04) : 278 - 278