Comparison between capnodynamic and thermodilution method for cardiac output monitoring during major abdominal surgery An observational study

被引:8
|
作者
Sigmundsson, Thorir S. [1 ,2 ]
Ohman, Tomas [1 ,2 ]
Hallback, Magnus [3 ]
Suarez-Sipmann, Fernando [4 ,5 ,6 ]
Wallin, Mats [2 ,3 ]
Oldner, Anders [1 ,2 ]
Hallsjo-Sander, Caroline [1 ,2 ]
Bjorne, Hakan [1 ,2 ]
机构
[1] Karolinska Univ Hosp, Perioperat Med & Intens Care, SE-17176 Solna, Sweden
[2] Karolinska Inst, Dept Physiol & Pharmacol, Stockholm, Sweden
[3] Maquet Crit Care AB, Solna, Sweden
[4] Hosp Univ La Princesa, Dept Intens Care, Madrid, Spain
[5] Uppsala Univ, Dept Surg Sci, Sect Anaesthesiol & Crit Care, Hedenstiemas Lab, Uppsala, Sweden
[6] Inst Salud Carlos III, GIBER Eniermedades Respiratorias, Madrid, Spain
关键词
PULMONARY BLOOD-FLOW; FLUID THERAPY; METAANALYSIS; PRECISION; ACCURACY; PERFORMANCE; AGREEMENT; OUTCOMES; ABILITY; RISK;
D O I
10.1097/EJA.0000000000001566
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND Cardiac output (CO) monitoring is the basis of goal-directed treatment for major abdominal surgery. A capnodynamic method estimating cardiac output (COEPBF) by continuously calculating nonshunted pulmonary blood flow has previously shown good agreement and trending ability when evaluated in mechanically ventilated pigs. OBJECTIVES To compare the performance of the capnodynamic method of CO monitoring with transpulmonary thermodilution (COTPTD) in patients undergoing major abdominal surgery. DESIGN Prospective, observational, method comparison study. Simultaneous measurements of COEPBF and COTPTD were performed before incision at baseline and before and after increased (+10 cmH(2)O) positive end-expiratory pressure (PEEP), activation of epidural anaesthesia and intra-operative events of hypovolemia and low CO. The first 25 patients were ventilated with PEEP5 cmH(2)O (PEEN, while in the last 10 patients, lung recruitment followed by individual PEEP adjustment (PEEPadi) was performed before protocol start. SETTING Karolinska University Hospital, Stockholm, Sweden. PATIENTS In total, 35 patients (>18 years) scheduled for major abdominal surgery with advanced hemodynamic monitoring were included in the study. MAIN OUTCOME MEASURES AND ANALYSIS Agreement and trending ability between COEPBF and COTPTD at different clinical moments were analysed with Bland-Altman and four quadrant plots. RESULTS In total, 322 paired values, 227 in PEEP5 and 95 in PEEPadj were analysed. Respectively, the mean COEPBF and COTPTD were 4.5 +/- 1.0 and 4.8 +/- 1.1 in the PEEP5 group and 4.9 +/- 1.2 and 5.0 +/- 1.0 l min(-1) in the PEEPadj group. Mean bias (levels of agreement) and percentage error (PE) were -0.2 (-2.2 to 1.7) l min(-1) and 41% for the PEEP5 group and -0.1 (-1.7 to 1.5) l min(-1) and 31% in the PEEP(adj )group. Concordance rates during changes in COEPBF and COTPTD were 92% in the PEEP5 group and 90% in the PEEPadj group. CONCLUSION COEPBF provides continuous noninvasive CO estimation with acceptable performance, which improved after lung recruitment and PEEP adjustment, although not interchangeable with COTPTD. This method may become a tool for continuous intra-operative CO monitoring during general anaesthesia in the future.
引用
收藏
页码:1242 / 1252
页数:11
相关论文
共 50 条
  • [41] Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    Michael Sander
    Claudia D Spies
    Herko Grubitzsch
    Achim Foer
    Marcus Müller
    Christian von Heymann
    Critical Care, 10
  • [42] Transoesophageal echocardiography accurately detects cardiac output variation:: a prospective comparison with thermodilution in cardiac surgery
    Parra, V.
    Fita, G.
    Rovira, I.
    Matute, P.
    Gomar, C.
    Pare, C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (02) : 135 - 143
  • [43] Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    Sander, Michael
    Spies, Claudia D.
    Grubitzsch, Herko
    Foer, Achim
    Mueller, Marcus
    von Heymann, Christian
    CRITICAL CARE, 2006, 10 (06):
  • [44] Cardiac output measurements during off-pump coronary surgery: comparison between partial rebreathing and pulmonary artery thermodilution - Reply
    Gueret, G.
    Kiss, G.
    Deredec, R.
    Bezon, E.
    Warnier, J.-P.
    Miossec, A.
    Corre, O.
    Arvieux, C. C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (08) : 721 - 721
  • [45] Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients
    Franchi, F.
    Silvestri, R.
    Cubattoli, L.
    Taccone, F. S.
    Donadello, K.
    Romano, S. M.
    Giomarelli, P.
    McBride, W. T.
    Scolletta, S.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (02) : 202 - 208
  • [46] Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: Comparison with thermodilution method
    Gujjar A.R.
    Muralidhar K.
    Banakal S.
    Gupta R.
    Sathyaprabha T.N.
    Jairaj P.S.
    Journal of Clinical Monitoring and Computing, 2008, 22 (03) : 175 - 180
  • [47] Comparison between measurements of cardiac output by thermodilution method and pulse dye densitometry using indocyanine green
    Watanabe, Y
    Takeda, A
    Hirakawa, M
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A117 - A117
  • [48] Urine output during pneumoperitoneal surgery: A comparison with abdominal wall lift method
    Ogihara, Y
    Issiki, A
    Omi, A
    Benson, KT
    Watanabe, S
    Goto, H
    ANESTHESIA AND ANALGESIA, 1997, 84 : S167 - S167
  • [49] Intraoperative neurophysiologic monitoring during cardiac surgery: an observational cohort study
    Brown, James
    Iyanna, Nidhi
    Yousef, Sarah
    Serna-Gallegos, Derek
    Zhu, Jianhui
    Yoon, Pyongsoo
    Kaczorowski, David
    Bonatti, Johannes
    Chu, Danny
    Balzer, Jeffrey
    Subramaniam, Kathirvel
    Thirumala, Parthasarathy D.
    Sultan, Ibrahim
    OPEN HEART, 2024, 11 (02):
  • [50] MAJOR ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENT DURING RAPID VOLUME INFUSION
    WETZEL, RC
    LATSON, TW
    ANESTHESIOLOGY, 1985, 62 (05) : 684 - 687