Reproducibility of thermodilution cardiac output determination in critically ill patients: Comparison between bolus and continuous method

被引:0
|
作者
LeTulzo, Y [1 ]
Belghith, M [1 ]
Seguin, P [1 ]
DallAva, J [1 ]
Monchi, M [1 ]
Thomas, R [1 ]
Dhainaut, JF [1 ]
机构
[1] PONTCHAILLOU UNIV HOSP,DEPT MED INTENS CARE UNIT,F-35033 RENNES 09,FRANCE
来源
JOURNAL OF CLINICAL MONITORING | 1996年 / 12卷 / 05期
关键词
critically ill; heart; cardiac output; hemodynamics; thermodilution technique; monitoring; catheterization;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. A semi-continuous thermodilution method (CCO) was recently developed to measure cardiac output with less risk of bacterial contamination, fluid overload, and user-induced errors than the classical bolus technique (BCO). Previous comparison between these two methods showed negligible bias. However, large limits of agreement suggest that the two methods are not interchangeable. We hypothesized that this poor agreement may be due to differences in reproducibility. Methods. In 23 critically ill patients, 369 paired measurements of CCO and BCO were compared (range of cardiac outputs: 2.8 to 16 L/min). The reproducibility of BCO and CCO methods was evaluated on a sample of 205 and 209 determinations, respectively. Results. The comparison between the CCO and the BCO methods confirmed previous results: i.e., small bias (-0.39 L/min) and large limits of agreement (-2.06 to +1.28 L/min). Reproducibility showed no bias for either the CCO or the BCO method. Limits of reproducibility agreement between repeated determinations were approximately 50% less for CCO than for BCO method: respectively -0.87 to +0.82 L/min for the CCO method and -1.56 to +1.37 L/min for the BCO method. Consequently the threshold necessary to ascertain that the difference-between two measurements was not due to the internal variability of the method (3 x SEM) was 0.39 for the CCO method and 0.75 L/min for the BCO method. Conclusion. Differences in reproducibility may explain the poor agreement between the CCO and BCO methods. The better reproducibility of the CCO method allows the detection of smaller variations in cardiac output and suggests the superiority of this new method.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [1] A comparison between oesophageal Doppler and continuous thermodilution for the measurement of cardiac output in critically ill patients
    JR Wilkinson
    C Ruff
    SK Patel
    RM Venn
    A Rhodes
    ED Bennett
    Critical Care, 4 (Suppl 1):
  • [2] COMPARISON OF CARDIAC OUTPUT MEASUREMENTS BETWEEN TRANSTHORACIC ECHOCARDIOGRAPHY AND THERMODILUTION METHOD IN CRITICALLY ILL PATIENTS
    Gomes, Flavia
    Arruda, Mariana
    Fagundes, Antonio, Jr.
    Amorim, Fabio Ferreira
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1491 - 1491
  • [3] CARDIAC-OUTPUT MONITORING BY CONTINUOUS THERMODILUTION IN CRITICALLY ILL PATIENTS
    LEFRANT, JY
    BRUELLE, P
    SAISSI, G
    DELACOUSSAYE, JE
    ELEDJAM, JJ
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 9 - 9
  • [4] Is continuous cardiac output measurement as accurate as intermittent bolus thermodilution cardiac output measurement in critically ill low ejection fraction patients?
    Gawlinski, A
    Attin, M
    CIRCULATION, 1998, 98 (17) : 693 - 693
  • [5] CARDIAC-OUTPUT MEASUREMENT IN CRITICALLY ILL PATIENTS - COMPARISON OF CONTINUOUS AND CONVENTIONAL THERMODILUTION TECHNIQUES
    LEFRANT, JY
    BRUELLE, P
    RIPART, J
    IBANEZ, F
    AYA, G
    PERAY, P
    SAISSI, G
    DELACOUSSAYE, JE
    ELEDJAM, JJ
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (11): : 972 - 976
  • [6] Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients
    Axler, O
    Tousignant, C
    Thompson, CR
    DallavaSantucci, J
    Phang, PT
    Russell, JA
    Walley, KR
    JOURNAL OF CRITICAL CARE, 1996, 11 (03) : 109 - 116
  • [7] Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    S. G. Sakka
    K. Reinhart
    A. Meier-Hellmann
    Intensive Care Medicine, 1999, 25 : 843 - 846
  • [8] Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    Sakka, SG
    Reinhart, K
    Meier-Hellmann, A
    INTENSIVE CARE MEDICINE, 1999, 25 (08) : 843 - 846
  • [9] Lack of agreement between thermodilution and fick cardiac output in critically ill patients
    Dhingra, VK
    Fenwick, JC
    Walley, KR
    Chittock, DR
    Ronco, JJ
    CHEST, 2002, 122 (03) : 990 - 997
  • [10] Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors
    Medin, DL
    Brown, DT
    Wesley, R
    Cunnion, RE
    Ognibene, FP
    JOURNAL OF CRITICAL CARE, 1998, 13 (04) : 184 - 189