The level of detail required in a deformable phantom to accurately perform quality assurance of deformable image registration

被引:7
|
作者
Saenz, Daniel L. [1 ]
Kim, Hojin [2 ]
Chen, Josephine [2 ]
Stathakis, Sotirios [1 ]
Kirby, Neil [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Univ Calif San Francisco, San Francisco, CA 94143 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 17期
关键词
deformable image registration; quality assurance; deformable phantoms; CT; RADIOTHERAPY; ALGORITHM;
D O I
10.1088/0031-9155/61/17/6269
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed. The virtual phantoms were warped to create two pairs consisting of undeformed and deformed images. Otsu's method was employed to create additional segmented image pairs of n distinct soft tissue CT number ranges (fat, muscle, etc). A realistic noise image was added to each image. Deformations were applied in MIM Software (MIM) and Velocity deformable multi-pass (DMP) and compared with the known warping. Images with more simulated tissue levels exhibit more contrast, enabling more accurate results. Deformation error (magnitude of the vector difference between known and predicted deformation) was used as a metric to evaluate how many CT number gray levels are needed for a phantom to serve as a realistic patient proxy. Stabilization of the mean deformation error was reached by three soft tissue levels for Velocity DMP and MIM, though MIM exhibited a persisting difference in accuracy between the discrete images and the unprocessed image pair. A minimum detail of three levels allows a realistic patient proxy for use with Velocity and MIM deformation algorithms.
引用
收藏
页码:6269 / 6280
页数:12
相关论文
共 50 条
  • [21] Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration
    Goerres, J.
    Uneri, A.
    Jacobson, M.
    Ramsay, B.
    De Silva, T.
    Ketcha, M.
    Han, R.
    Manbachi, A.
    Vogt, S.
    Kleinszig, G.
    Wolinsky, J-P
    Osgood, G.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 9018 - 9038
  • [22] Evaluation of a deformable image registration quality assurance tool for head and neck cancer patients
    Mee, Molly
    Stewart, Kate
    Lathouras, Marika
    Truong, Helen
    Hargrave, Catriona
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 284 - 293
  • [23] A deformable phantom for quality assurance in 4D radiotherapy
    Margeanu, M.
    Heath, E.
    Stroian, G.
    Seuntjens, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S80 - S81
  • [24] Biomechanical quality assurance criteria for deformable image registration algorithms used in radiotherapy guidance
    Zachiu, Cornel
    de Senneville, Baudouin Denis
    Raaymakers, Bas W.
    Ries, Mario
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01):
  • [25] Two Quality Assurance Metrics for Deformable Image Registration-Based Dose Accumulation
    Kainz, K.
    Zhong, H.
    Tai, A.
    Ahunbay, E. E.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E275 - E276
  • [26] Patient-specific deformable image registration quality assurance based on feature points
    Park, P. C.
    Koay, E.
    Yang, J.
    Suh, Y.
    Das, P.
    Crane, C.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S900 - S901
  • [27] Deformable image registration
    Shen, JK
    Matuszewski, BJ
    Shark, LK
    2005 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), VOLS 1-5, 2005, : 3353 - 3356
  • [28] Characterization of a new physical phantom for testing rigid and deformable image registration
    Wu, Richard Y.
    Liu, Amy Y.
    Wisdom, Paul
    Zhu, Xiaorong Ronald
    Frank, Steven J.
    Fuller, Clifton D.
    Gunn, Gary Brandon
    Palmer, Matthew B.
    Wages, Cody A.
    Gillin, Michael T.
    Yang, Jinzhong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 145 - 153
  • [29] Validation of Deformable Image Registration Software Using a Standard CT Phantom
    Verdecchia, K.
    Qiu, L.
    Magnelli, A.
    Balik, S.
    Kost, S.
    Godley, A.
    Xia, P.
    MEDICAL PHYSICS, 2017, 44 (06) : 3174 - 3175
  • [30] Construction of an anthropopathic abdominal phantom for accuracy validation of deformable image registration
    Liao, Y. L.
    Chen, H. B.
    Zhou, L. H.
    Zhen, X.
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S717 - S723