The level of detail required in a deformable phantom to accurately perform quality assurance of deformable image registration

被引:7
|
作者
Saenz, Daniel L. [1 ]
Kim, Hojin [2 ]
Chen, Josephine [2 ]
Stathakis, Sotirios [1 ]
Kirby, Neil [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Univ Calif San Francisco, San Francisco, CA 94143 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 17期
关键词
deformable image registration; quality assurance; deformable phantoms; CT; RADIOTHERAPY; ALGORITHM;
D O I
10.1088/0031-9155/61/17/6269
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed. The virtual phantoms were warped to create two pairs consisting of undeformed and deformed images. Otsu's method was employed to create additional segmented image pairs of n distinct soft tissue CT number ranges (fat, muscle, etc). A realistic noise image was added to each image. Deformations were applied in MIM Software (MIM) and Velocity deformable multi-pass (DMP) and compared with the known warping. Images with more simulated tissue levels exhibit more contrast, enabling more accurate results. Deformation error (magnitude of the vector difference between known and predicted deformation) was used as a metric to evaluate how many CT number gray levels are needed for a phantom to serve as a realistic patient proxy. Stabilization of the mean deformation error was reached by three soft tissue levels for Velocity DMP and MIM, though MIM exhibited a persisting difference in accuracy between the discrete images and the unprocessed image pair. A minimum detail of three levels allows a realistic patient proxy for use with Velocity and MIM deformation algorithms.
引用
收藏
页码:6269 / 6280
页数:12
相关论文
共 50 条
  • [31] Objective Assessment of the Quality and Accuracy of Deformable Image Registration
    Jurkovic, Ines-Ana
    Papanikolaou, Nikos
    Stathakis, Sotirios
    Kirby, Neil
    Mavroidis, Panayiotis
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (03) : 156 - 167
  • [32] QA of deformable image registration
    Kessler, Marc
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S9 - S9
  • [33] Comparison of two deformable registration software using an in-house "deformable phantom"
    Koutsouvelis, N.
    Rouzaud, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 838 - 839
  • [34] Use of a DVH overlay technique for quality assurance of deformable image registration-based dose accumulation
    Kainz, Kristofer
    Garcia Alvarez, Juan
    Zhong, Hualiang
    Lim, Sara
    Ahunbay, Ergun
    Tai, An
    Erickson, Beth
    Lawton, Colleen
    Li, X. Allen
    MEDICAL PHYSICS, 2022, 49 (01) : 611 - 623
  • [35] Validation of Accuracy in Deformable Image Registration by Use of Three-Dimensional Phantom
    Kobayashi, M.
    Hayashi, N.
    Egami, K.
    Yasui, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [36] A Three-Dimensional Thermoplastic Prostate Phantom for Evaluation of Deformable Image Registration
    Reber, C.
    Neo, A.
    Schoenhoff, E.
    Kirby, N.
    Singhrao, K.
    Pouliot, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Accuracy of a deformable image registration software in shape and volume recovery of phantom images
    Pallotta, S.
    Simontacchi, G.
    Livi, L.
    Bucciolini, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S267 - S267
  • [38] Quality Assurance of Deformation Algorithms Using a Two-Dimensional Deformable Phantom
    Kirby, N.
    Chuang, C.
    Pouliot, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3821 - +
  • [39] Is There a Threshold Limit in the Accuracy of Deformable Image Registration (DIR)? A Validation Study Using Deformable Bladder Phantom with Implanted Markers
    Varadhan, R.
    Hui, S.
    Overbeck, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 174 - 175
  • [40] Visualization of Deformable Image Registration Quality Using Local Image Dissimilarity
    Schlachter, Matthias
    Fechter, Tobias
    Jurisic, Miro
    Schimek-Jasch, Tanja
    Oehlke, Oliver
    Adebahr, Sonja
    Birkfellner, Wolfgang
    Nestle, Ursula
    Buehler, Katja
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (10) : 2319 - 2328