High-resolution video-based EPID for cone beam CT

被引:0
|
作者
Ghelmansarai, FA [1 ]
Bani-Hashemi, A [1 ]
Celi, JC [1 ]
Hernandez, P [1 ]
Calderon, E [1 ]
Mitschke, M [1 ]
机构
[1] Siemens Med Solut Inc, Concord, CA USA
关键词
electronic portal imaging device; cone beam CT; high-resolution portal imaging; EPID electronic readout;
D O I
10.1117/12.480484
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A high-resolution video (HRV) based EPID that is capable of matching the high spatial resolution and SNR (signal to noise ratio) of a-Si flat panel devices was developed at Siemens OCS (Oncology Care Systems) for cone beam CT. This system is using a high resolution CCD camera (1300 x 1030). The optical components-and scintillator screen were modified to generate high-resolution images. A Pips-Pro QC3 phantom was used to compare the spatial resolution and the contrast to noise ratio (CNR) of a-Si flat panel (1024x1624) and HRV system. The QC phantom Was placed at the linear accelerator iso-center, and the detectors were placed 40cm below iso-center. The measured f50 for the Siemens a-Si flat panel and HRV are 0.49 lp/mm, and 0.43 lp/mm; respectively. The image of the flat panel had already been corrected for Offset, Gain and Defective pixels; however, no correction was performed on the HRV system. Due to the fast readout of HRV, small pixel size, and adjustable camera lens aperture, a thicker scintillator screen would have resulted in an increase in SNR without sensor saturation during radiation treatment, imaging. this is one of the main advantages of this system compared to the flat panels, and it makes the system ideal for cone beam reconstructions as well as regular therapy imaging. A new electronic readout is implemented in HRV control circuit that will synchronize the image-acquisition with the linear accelerator, and thereby increases the SNR.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [31] High-resolution video mosaicing
    Smolic, A
    Wiegand, T
    2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, 2001, : 872 - 875
  • [32] Use of in-room cone-beam CT and EPID to assess the dose of the day
    van Zijtveld, M.
    Dirkx, M. L. P.
    Heijmen, B. J. M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S231 - S231
  • [33] HIGH-RESOLUTION ALGORITHM FOR FAN BEAM-CT SYSTEM.
    Horiba, Isao
    Yanaka, Shigenobu
    Iwata, Akira
    Suzumura, Nobuo
    Systems and Computers in Japan, 1986, 17 (07) : 19 - 29
  • [34] Gantry-Free High-Resolution Cone- Beam CT: Efficacy for Distal Radius and Scaphoid Fracture Detection and Characterization
    Grunz, Jan-Peter
    Jordan, Martin C.
    Schmitt, Rainer
    Luetkens, Karsten S.
    Huflage, Henner
    Meffert, Rainer H.
    Bley, Thorsten A.
    Kunz, Andreas S.
    ACADEMIC RADIOLOGY, 2023, 30 (07) : 1358 - 1366
  • [35] Quantitative analysis of high-resolution, contrast-enhanced, cone-beam CT for the detection of intracranial in-stent hyperplasia
    Flood, Thomas F.
    van der Bom, Imramsjah M. J.
    Strittmatter, Lara
    Puri, Ajit S.
    Hendricks, Gregory M.
    Wakhloo, Ajay K.
    Gounis, Matthew J.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (02) : 118 - 125
  • [36] Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery
    Kanayama, Seisaku
    Hara, Takayuki
    Hamada, Yusuke
    Matsumaru, Yuji
    NEURORADIOLOGY, 2015, 57 (02) : 155 - 162
  • [37] Target delineation for radiosurgery of a small brain arteriovenous malformation using high-resolution contrast-enhanced cone beam CT
    van der Bom, Imramsjah M. J.
    Gounis, Matthew J.
    Ding, Linda
    Kuehn, Anna Luisa
    Goff, David
    Puri, Ajit S.
    Wakhloo, Ajay K.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (05) : e34
  • [38] High-Resolution Extremity Cone-Beam CT with a CMOS Detector: Evaluation of a Clinical Prototype in Quantitative Assessment of Bone Microarchitecture
    Cao, Q.
    Brehler, M.
    Sisniega, A.
    Tilley, S., II
    Bhruwani, M. M. Shiraz
    Stayman, J. W.
    Yorkston, J.
    Siewerdsen, H.
    Zbijewski, W.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [39] Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery
    Seisaku Kanayama
    Takayuki Hara
    Yusuke Hamada
    Yuji Matsumaru
    Neuroradiology, 2015, 57 : 155 - 162
  • [40] High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data
    Varslot, T.
    Kingston, A.
    Myers, G.
    Sheppard, A.
    MEDICAL PHYSICS, 2011, 38 (10) : 5459 - 5476