High-resolution video-based EPID for cone beam CT

被引:0
|
作者
Ghelmansarai, FA [1 ]
Bani-Hashemi, A [1 ]
Celi, JC [1 ]
Hernandez, P [1 ]
Calderon, E [1 ]
Mitschke, M [1 ]
机构
[1] Siemens Med Solut Inc, Concord, CA USA
关键词
electronic portal imaging device; cone beam CT; high-resolution portal imaging; EPID electronic readout;
D O I
10.1117/12.480484
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A high-resolution video (HRV) based EPID that is capable of matching the high spatial resolution and SNR (signal to noise ratio) of a-Si flat panel devices was developed at Siemens OCS (Oncology Care Systems) for cone beam CT. This system is using a high resolution CCD camera (1300 x 1030). The optical components-and scintillator screen were modified to generate high-resolution images. A Pips-Pro QC3 phantom was used to compare the spatial resolution and the contrast to noise ratio (CNR) of a-Si flat panel (1024x1624) and HRV system. The QC phantom Was placed at the linear accelerator iso-center, and the detectors were placed 40cm below iso-center. The measured f50 for the Siemens a-Si flat panel and HRV are 0.49 lp/mm, and 0.43 lp/mm; respectively. The image of the flat panel had already been corrected for Offset, Gain and Defective pixels; however, no correction was performed on the HRV system. Due to the fast readout of HRV, small pixel size, and adjustable camera lens aperture, a thicker scintillator screen would have resulted in an increase in SNR without sensor saturation during radiation treatment, imaging. this is one of the main advantages of this system compared to the flat panels, and it makes the system ideal for cone beam reconstructions as well as regular therapy imaging. A new electronic readout is implemented in HRV control circuit that will synchronize the image-acquisition with the linear accelerator, and thereby increases the SNR.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [21] Quantitative Evaluation of Bone Microstructure using High-Resolution Extremity Cone-Beam CT with a CMOS Detector
    Subramanian, S.
    Brehler, M.
    Cao, Q.
    Gonzalez, F. J. Quevedo
    Breighner, R. E.
    Canino, J. A.
    Wright, T.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [22] Clinically relevant human temporal bone measurements using novel high-resolution cone-beam CT
    Jing Zou
    Jaakko Lhelm
    Antti Arnisalo
    Ilmari Pyykk
    JournalofOtology, 2017, 12 (01) : 9 - 17
  • [23] Improvement of the accuracy of EPID lung image analysis validated with Cone Beam CT
    Buijs, M
    Van Herk, M
    Betgen, A
    Sonke, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S98 - S98
  • [24] Application of a Direct Scatter Correction Algorithm to EPID-Based Megavoltage Cone-Beam CT
    Sramek, B.
    Waggener, R.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [25] Interfacing and Testing High-Resolution, Video-Based Avionics and Mission Systems that Use ARINC 818-3
    Keller, Tim
    2023 IEEE/AIAA 42ND DIGITAL AVIONICS SYSTEMS CONFERENCE, DASC, 2023,
  • [26] Imaging Optimization of Temporal Bones With Cochlear Implant Using a High-resolution Cone Beam CT and the Corresponding Effective Dose
    Zou, Jing
    Koivisto, Juha
    Lahelma, Jaakko
    Aarnisalo, Antti
    Wolff, Jan
    Pyykko, Ilmari
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2015, 124 (06): : 466 - 473
  • [27] Cone-beam CT of vessel phantoms: Comparison of image intensifier and high-resolution micro-angiographic systems
    Ionita, C
    Chityala, R
    Rudin, S
    Hoffmann, K
    Kyprianou, I
    Bednarek, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1423 - 1423
  • [28] Planar Cone-Beam Computed Tomography for High-Resolution Industrial Application
    Liu, Tong
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [29] Cache-Aware GPU Optimization for Out-of-Core Cone Beam CT Reconstruction of High-Resolution Volumes
    Lu, Yuechao
    Ino, Fumihiko
    Hagihara, Kenichi
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2016, E99D (12): : 3060 - 3071
  • [30] BEST IN PHYSICS (IMAGING): High-Resolution Cone-Beam CT of the Extremities and Cancellous Bone Architecture with a CMOS Detector
    Cao, Q.
    Brehler, M.
    Sisniega, A.
    Marinetto, E.
    Zyazin, A.
    Peters, I.
    Stayman, J.
    Yorkston, J.
    Siewerdsen, J.
    Zbijewski, W.
    MEDICAL PHYSICS, 2016, 43 (06) : 3797 - 3797