This paper theoretically analyzes the frequency component of the projection data, obtained by the third-generation CT system using a wide-angle fan beam. It is shown that the projection data contain the effective frequency component above the Nyquist frequency determined by the spacing between detectors. Then a new algorithm is proposed which utilizes that effective frequency component. The usefulness of the algorithm is examined by an experiment using a phantom and the human body. It is shown as a result that the new algorithm can realize spatial resolution corresponding to approximately twice the Nyquist frequency determined by the detector spacing. Using this algorithm, the spatial resolution of the CT image can be improved without decreasing the detector spacing.
引用
收藏
页码:19 / 29
相关论文
共 50 条
  • [1] FAST RECONSTRUCTION ALGORITHM FOR FAN-BEAM CT SYSTEM.
    Isao, Horiba
    Iwata, Akira
    Suzumura, Nobuo
    Yamagishi, Nobutoshi
    Systems and Computers in Japan, 1986, 17 (07) : 1 - 9
  • [2] Inter-observer image quality analysis of megavoltage cone beam-CT versus megavoltage fan beam-CT
    Meadows, J.
    Bichay, T.
    Chen, C.
    Schippers, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2382 - 2382
  • [3] High-Resolution Extremity Cone-Beam CT Prototype System
    Bernstein, M.
    Karp, J.
    Li, K.
    Zbijewski, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E539 - E539
  • [4] EFFECTS OF DATA SAMPLING RATE ON IMAGE QUALITY IN FAN-BEAM CT SYSTEM.
    Iwata, Akira
    Yamagishi, Nobutoshi
    Suzumura, Nobuo
    Horiba, Isao
    Systems and Computers in Japan, 1985, 16 (02) : 77 - 84
  • [5] IMAGING PROPERTIES OF A HIGH-RESOLUTION CT SYSTEM
    SCHULTZ, E
    DIGITALE BILDDIAGNOSTIK, 1989, 9 (04): : 135 - 139
  • [6] ASSESSMENT OF VERTEBRAL DEFORMATION WITH A HIGH-RESOLUTION FAN-BEAM BONE DENSITOMETER
    LANG, T
    FAN, B
    WU, C
    LI, J
    TAKADA, M
    GLUER, CC
    GENANT, H
    JOURNAL OF BONE AND MINERAL RESEARCH, 1995, 10 : S367 - S367
  • [7] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Altman, A
    Koehler, T
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2973 - 2977
  • [8] High-Resolution Cone Beam CT Reconstruction for Motion Tracking
    Cai, W.
    Li, T.
    Li, X.
    Zhang, P.
    Tang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E568 - E568
  • [9] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Koehler, T
    Altman, A
    Proksa, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 247 - 255
  • [10] Development of High-Resolution X-ray CT System Using Parallel Beam Geometry
    Yoneyama, Akio
    Baba, Rika
    Hyodo, Kazuyuki
    Takeda, Tohoru
    Nakano, Haruhisa
    Maki, Koutaro
    Sumitani, Kazushi
    Hirai, Yasuharu
    XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696