High-resolution images of cone beam collimated CT scans

被引:6
|
作者
Shechter, G [1 ]
Koehler, T
Altman, A
Proksa, R
机构
[1] Philips Med Syst Technol, IL-31004 Haifa, Israel
[2] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
关键词
cone beam; helical computed tomography (CT); image reconstruction;
D O I
10.1109/TNS.2004.843110
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a novel reconstruction algorithm for high-transaxial-resolution cone-beam computed tomography (CT). Two ideas are combined to achieve this: First, the ray-offset technique, which is well-known for two-dimensional reconstruction, is adapted to the case of cone-beam CT. Instead of interleaving parallel re-binned projections from opposite directions during pre-processing before radial re-binning and filtering, the parallel re-binned projections are interleaved with virtual projections, which contain only zeros. These new projections are processed further as usual. The actual combination of opposite measured projections is moved into the back-projection step of the reconstruction. The second idea is the so-called frequency-split technique, which is designed to minimize cone-beam artifacts. Observing that cone beam artifacts contain mainly low-frequency components, the reconstructed image is a combination of two independent reconstructions with differently modified reconstruction filters and different amounts of redundant data. A high-frequency image is reconstructed with the ray offset technique using all the redundant data, and a high-pass filter leading to a suppression of low-frequency artifacts, while the low-frequency components of the image are reconstructed by using little redundant data only. The pro- posed technique is applied to the WEDGE algorithm and helical acquisition.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 50 条
  • [1] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Altman, A
    Koehler, T
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2973 - 2977
  • [2] High-Resolution Cone Beam CT Reconstruction for Motion Tracking
    Cai, W.
    Li, T.
    Li, X.
    Zhang, P.
    Tang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E568 - E568
  • [3] High-resolution video-based EPID for cone beam CT
    Ghelmansarai, FA
    Bani-Hashemi, A
    Celi, JC
    Hernandez, P
    Calderon, E
    Mitschke, M
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 127 - 136
  • [4] High-Resolution Extremity Cone-Beam CT Prototype System
    Bernstein, M.
    Karp, J.
    Li, K.
    Zbijewski, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E539 - E539
  • [5] ARTIFACTS AND PITFALLS OF HIGH-RESOLUTION CT SCANS
    HAHN, FJ
    CHU, WK
    ANDERSON, JC
    DOBRY, CA
    CRC CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 1985, 25 (01) : 61 - 77
  • [6] High-resolution FPD cone-beam CT for dental and orthopedic surgery
    Baba, R
    Ueda, K
    Kadomura, T
    RADIOLOGY, 2002, 225 : 194 - 194
  • [7] Three-rooted premolar analyzed by high-resolution and cone beam CT
    Caroline Marca
    Paul M. H. Dummer
    Susan Bryant
    Fabiana Vieira Vier-Pelisser
    Marcus Vinicius Reis Só
    Vania Fontanella
    Vinicius D’avila Dutra
    José Antonio Poli de Figueiredo
    Clinical Oral Investigations, 2013, 17 : 1535 - 1540
  • [8] Three-rooted premolar analyzed by high-resolution and cone beam CT
    Marca, Caroline
    Dummer, Paul M. H.
    Bryant, Susan
    Vier-Pelisser, Fabiana Vieira
    Reis So, Marcus Vinicius
    Fontanella, Vania
    Dutra, Vinicius D'avila
    Poli de Figueiredo, Jose Antonio
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (06) : 1535 - 1540
  • [9] Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT
    Cao, Qian
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Yorkston, John
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : 7263 - 7281
  • [10] Efficacy of high-resolution cone-beam CT in the evaluation of carotid atheromatous plaque
    Tanabe, Jun
    Tanaka, Michihiro
    Kadooka, Keisuke
    Hadeishi, Hiromu
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) : 305 - 308