High-resolution video-based EPID for cone beam CT

被引:0
|
作者
Ghelmansarai, FA [1 ]
Bani-Hashemi, A [1 ]
Celi, JC [1 ]
Hernandez, P [1 ]
Calderon, E [1 ]
Mitschke, M [1 ]
机构
[1] Siemens Med Solut Inc, Concord, CA USA
关键词
electronic portal imaging device; cone beam CT; high-resolution portal imaging; EPID electronic readout;
D O I
10.1117/12.480484
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A high-resolution video (HRV) based EPID that is capable of matching the high spatial resolution and SNR (signal to noise ratio) of a-Si flat panel devices was developed at Siemens OCS (Oncology Care Systems) for cone beam CT. This system is using a high resolution CCD camera (1300 x 1030). The optical components-and scintillator screen were modified to generate high-resolution images. A Pips-Pro QC3 phantom was used to compare the spatial resolution and the contrast to noise ratio (CNR) of a-Si flat panel (1024x1624) and HRV system. The QC phantom Was placed at the linear accelerator iso-center, and the detectors were placed 40cm below iso-center. The measured f50 for the Siemens a-Si flat panel and HRV are 0.49 lp/mm, and 0.43 lp/mm; respectively. The image of the flat panel had already been corrected for Offset, Gain and Defective pixels; however, no correction was performed on the HRV system. Due to the fast readout of HRV, small pixel size, and adjustable camera lens aperture, a thicker scintillator screen would have resulted in an increase in SNR without sensor saturation during radiation treatment, imaging. this is one of the main advantages of this system compared to the flat panels, and it makes the system ideal for cone beam reconstructions as well as regular therapy imaging. A new electronic readout is implemented in HRV control circuit that will synchronize the image-acquisition with the linear accelerator, and thereby increases the SNR.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [1] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Altman, A
    Koehler, T
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2973 - 2977
  • [2] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Koehler, T
    Altman, A
    Proksa, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 247 - 255
  • [3] High-Resolution Cone Beam CT Reconstruction for Motion Tracking
    Cai, W.
    Li, T.
    Li, X.
    Zhang, P.
    Tang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E568 - E568
  • [4] High-Resolution Extremity Cone-Beam CT Prototype System
    Bernstein, M.
    Karp, J.
    Li, K.
    Zbijewski, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E539 - E539
  • [5] Image-Based Motion Compensation for High-Resolution Extremities Cone-Beam CT
    Sisniega, A.
    Stayman, J. W.
    Cao, Q.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [6] High-resolution FPD cone-beam CT for dental and orthopedic surgery
    Baba, R
    Ueda, K
    Kadomura, T
    RADIOLOGY, 2002, 225 : 194 - 194
  • [7] Three-rooted premolar analyzed by high-resolution and cone beam CT
    Caroline Marca
    Paul M. H. Dummer
    Susan Bryant
    Fabiana Vieira Vier-Pelisser
    Marcus Vinicius Reis Só
    Vania Fontanella
    Vinicius D’avila Dutra
    José Antonio Poli de Figueiredo
    Clinical Oral Investigations, 2013, 17 : 1535 - 1540
  • [8] Three-rooted premolar analyzed by high-resolution and cone beam CT
    Marca, Caroline
    Dummer, Paul M. H.
    Bryant, Susan
    Vier-Pelisser, Fabiana Vieira
    Reis So, Marcus Vinicius
    Fontanella, Vania
    Dutra, Vinicius D'avila
    Poli de Figueiredo, Jose Antonio
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (06) : 1535 - 1540
  • [9] Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT
    Cao, Qian
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Yorkston, John
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : 7263 - 7281
  • [10] Efficacy of high-resolution cone-beam CT in the evaluation of carotid atheromatous plaque
    Tanabe, Jun
    Tanaka, Michihiro
    Kadooka, Keisuke
    Hadeishi, Hiromu
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) : 305 - 308