Application of video imaging for improvement of patient set-up

被引:24
|
作者
Ploeger, LS [1 ]
Frenay, M [1 ]
Betgen, A [1 ]
de Bois, JA [1 ]
Gilhuijs, KGA [1 ]
van Herk, M [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiotherapy, Antoni Van Leeuwenhoek Hosp, NL-1066 CX Amsterdam, Netherlands
关键词
patient set-up; set-up verification; video imaging; prostate cancer; electronic portal imaging;
D O I
10.1016/S0167-8140(03)00230-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis. Material and methods: The camera was mounted. in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method. Results: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm. Conclusion: Video imaging is an accurate technique for measuring the set-up of prostate cancer patients in the LR direction. The outline of the patient is a more accurate estimate of the set-up of the bony anatomy than the marker on the patient's abdomen. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 50 条
  • [41] Designing a maximum precision interferometric particle imaging set-up
    Dehaeck, S.
    van Beeck, J. P. A. J.
    EXPERIMENTS IN FLUIDS, 2007, 42 (05) : 767 - 781
  • [42] Robot set-up time in urologic surgery: an opportunity for quality improvement
    David J. Kozminski
    Matthieu J. Cerf
    Paul J. Feustel
    Barry A. Kogan
    Journal of Robotic Surgery, 2020, 14 : 745 - 752
  • [43] Robot set-up time in urologic surgery: an opportunity for quality improvement
    Kozminski, David J.
    Cerf, Matthieu J.
    Feustel, Paul J.
    Kogan, Barry A.
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (05) : 745 - 752
  • [44] Patient set-up verification with on-line MV-portal imaging and displacement adjustment by the technician
    Agnér, E
    Petri, A
    Sorcini, B
    Näslund, I
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S227 - S227
  • [45] Comparison of image registration tools used for daily KV imaging-based patient set-up
    Lindsay, P.
    Choi, B.
    Bucci, M.
    Zhang, L.
    Dong, L.
    Kudchadker, R.
    Zhu, X.
    Balter, P.
    MEDICAL PHYSICS, 2007, 34 (06) : 2375 - 2375
  • [46] THE ESTABLISHMENT OF THE SET-UP ION-NEUTRAL REACTION AND APPLICATION
    Peng Yuexiang
    Chen Xinguo
    Song Fenhong
    Qiu Lianxiong
    ACTA PHYSICO-CHIMICA SINICA, 1993, 9 (02) : 145 - 147
  • [47] Adaptive set-up correction (ASC) to account for set-up errors in prostate radiotherapy
    Lauve, A
    Siebers, J
    Crimaldi, A
    Hagan, M
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S332 - S332
  • [48] Development of a discrimination set-up
    Celiktas, C.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2008, 36 (04) : 432 - 436
  • [49] The perfect set-up for change
    不详
    ZKG INTERNATIONAL, 2018, 71 (03): : 22 - 25
  • [50] A NOTE ON WAVE SET-UP
    LONGUETHIGGINS, MS
    STEWART, RW
    JOURNAL OF MARINE RESEARCH, 1963, 21 (01) : 4 - 10