Application of video imaging for improvement of patient set-up

被引:24
|
作者
Ploeger, LS [1 ]
Frenay, M [1 ]
Betgen, A [1 ]
de Bois, JA [1 ]
Gilhuijs, KGA [1 ]
van Herk, M [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiotherapy, Antoni Van Leeuwenhoek Hosp, NL-1066 CX Amsterdam, Netherlands
关键词
patient set-up; set-up verification; video imaging; prostate cancer; electronic portal imaging;
D O I
10.1016/S0167-8140(03)00230-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis. Material and methods: The camera was mounted. in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method. Results: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm. Conclusion: Video imaging is an accurate technique for measuring the set-up of prostate cancer patients in the LR direction. The outline of the patient is a more accurate estimate of the set-up of the bony anatomy than the marker on the patient's abdomen. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 50 条
  • [31] Application of an offline patient set-up procedure using MVCT for prostate cancer helical tomotherapy
    Broggi, S
    Florino, C
    Tavilla, A
    Cozzarini, C
    Di Muzio, N
    Cattaneo, G
    Fazio, F
    Calandrino, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S222 - S222
  • [32] The Shaadi Set-Up
    Day, Meagan
    LIBRARY JOURNAL, 2021, 146 (08) : 62 - 62
  • [33] What a set-up!
    1600, PennWell Publ Co, Tulsa, OK, USA (18):
  • [34] Automatic set-up
    Oakham, Martin
    Engineer, 2007, 293 (7730) : 38 - 40
  • [35] Experimental set-up
    Prace Naukowe Instytutu Technologii Budowy Maszyn Politechniki Wroclawskiej, 1991, 48 (13):
  • [36] Registration of electronic portal images for patient set-up verification
    Matsopoulos, GK
    Asvestas, PA
    Delibasis, KK
    Kouloulias, V
    Uzunoglu, N
    Karaiskos, P
    Sandilos, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3279 - 3289
  • [37] Imaging through scattering media with the double aperture set-up
    Handojo, A
    Sumihar, JH
    OPTICS AND LASER TECHNOLOGY, 2001, 33 (06): : 389 - 392
  • [38] Uncertainty in patient set-up margin analysis in radiation therapy
    Suzuki, Junji
    Tateoka, Kunihiko
    Shima, Katsumi
    Yaegashi, Yuji
    Fujimoto, Kazunori
    Saitoh, Yuichi
    Nakata, Akihiro
    Abe, Tadanori
    Nakazawa, Takuya
    Sakata, Kouichi
    Hareyama, Masato
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (04) : 615 - 619
  • [39] Counselling in an in-patient set-up: Role in mainstream healthcare
    Chhibber, Kamna
    Parikh, Samir
    Sondhi, Roshni
    APPLIED PSYCHOLOGY, 2016, : 58 - 77
  • [40] Designing a maximum precision interferometric particle imaging set-up
    S. Dehaeck
    J. P. A. J. van Beeck
    Experiments in Fluids, 2007, 42 : 767 - 781