Application of video imaging for improvement of patient set-up

被引:24
|
作者
Ploeger, LS [1 ]
Frenay, M [1 ]
Betgen, A [1 ]
de Bois, JA [1 ]
Gilhuijs, KGA [1 ]
van Herk, M [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiotherapy, Antoni Van Leeuwenhoek Hosp, NL-1066 CX Amsterdam, Netherlands
关键词
patient set-up; set-up verification; video imaging; prostate cancer; electronic portal imaging;
D O I
10.1016/S0167-8140(03)00230-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis. Material and methods: The camera was mounted. in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method. Results: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm. Conclusion: Video imaging is an accurate technique for measuring the set-up of prostate cancer patients in the LR direction. The outline of the patient is a more accurate estimate of the set-up of the bony anatomy than the marker on the patient's abdomen. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 50 条
  • [1] Efficient application of megavolt imaging for patient set-up verification
    Quint, S.
    Os van, M. J. H.
    Boer de, J. C. J.
    Dirkx, M. L. P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S205 - S205
  • [2] Application of flat panel digital imaging for improvement of ocular melanoma patient set-up in proton beam therapy
    Daftari, Inder K.
    Essert, Timothy
    Phillips, Theodore L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (02): : 628 - 634
  • [3] CLINICAL-APPLICATION OF AN ELECTRONIC IMAGING DEVICE FOR ASSISTING PATIENT SET-UP IN RADIOTHERAPY
    WADE, JP
    NICHOLAS, D
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (763): : 596 - 602
  • [4] Patient set-up in radiotherapy with video-based positioning system
    Tao, S
    Wu, A
    Wu, Y
    Chen, Y
    Zhang, J
    CLINICAL ONCOLOGY, 2006, 18 (04) : 363 - 366
  • [5] Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
    Rudat, Volker
    Hammoud, Mohamed
    Pillay, Yogin
    Alaradi, Abdul Aziz
    Mohamed, Adel
    Altuwaijri, Saleh
    RADIATION ONCOLOGY, 2011, 6
  • [6] Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
    Volker Rudat
    Mohamed Hammoud
    Yogin Pillay
    Abdul Aziz Alaradi
    Adel Mohamed
    Saleh Altuwaijri
    Radiation Oncology, 6
  • [7] Patient set-up and verification for IMRT
    Jones, AO
    Kleiman, MT
    Vigneri, PM
    Kayal, NL
    RADIOLOGY, 1999, 213P : 406 - 406
  • [8] Implementing and characterizing a video reflectometry set-up
    Cunill-Rodriguez, Margarita
    Castro-Ramos, Jorge
    Vazquez-Montiel, Sergio
    Delgado-Atencio, Jose A.
    RIAO/OPTILAS 2007, 2008, 992 : 632 - +
  • [9] Measurement of patient set-up variations using an electronic portal imaging system
    Mubata, CD
    Bidmead, AM
    Jones, CH
    QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 114 - 118
  • [10] Video carts: A logical set-up equals simple troubleshooting
    Trace Services Inc.
    Biomed. Instrum. Technol., 2008, 2 (125-126): : 125 - 126