Application of flat panel digital imaging for improvement of ocular melanoma patient set-up in proton beam therapy

被引:3
|
作者
Daftari, Inder K. [1 ]
Essert, Timothy [2 ]
Phillips, Theodore L. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Univ Calif Davis, Crocker Nucl Lab, Davis, CA 95616 USA
关键词
Proton beam therapy; Uveal melanoma; Flat panel digital imaging; Image-guided radiation; Patient positioning; UVEAL MELANOMA; NEOVASCULAR GLAUCOMA; CHOROIDAL MELANOMA; ION RADIOTHERAPY; IRRADIATION; EXPERIENCE; DEVICES; EYE;
D O I
10.1016/j.nima.2008.10.008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to reduce the dose to Surrounding critical tissues and also minimize the probability of recurrence of the tumor the placement of radiation fields relative to patient anatomy is very essential in proton beam therapy of ocular tumors. To achieve this objective, patient setup and field placement have been verified before treatment by analyzing the portal images obtained with Polaroid film-camera system. The Polaroid films are becoming expensive and obsolete, making new methods of verifying the patient treatment position essential. The objective of this study was to implement an orthogonal flat panel digital imaging (FPDI) system as a tool to image-guided radiation therapy (IGRT) on the UC Davis cyclotron proton beam therapy line and to use the system for patient setup verification. The image quality of the system is sufficient to see an air hole with a diameter of 0.5 min at a depth of 9 mm, in a 10 cm Lucite phantom. The subject contrast of the FPDI system varied from 16% to 29% by varying the size of the air hole in the phantom from I to 5 min and changing the depth from 9 to 15 mm. The subject contrast for 0.5 min air hole was 11%. The comparison of the setup variations as measured from Polaroid port films and FPDI was 0.1 +/- 0.7 min in the X-direction, 0.2 +/- 0.2 min in the Y-direction and 0.04 +/- 0.1 min in Z-direction, respectively. The day-to-day positional variations in-patient set-ups were studied for 30 patients using the FPDI system. The patient position set-up on first day of treatment [defined by the X, Y. Z coordinates of the chair and head holder] was registered as the reference image. The comparison of day-to-day patient position with reference image indicated net translation along the three orthogonal axes as 0.3 +/- 1.88 min in right-left direction, -0.3 +/- 1.78 in superior-inferior direction and -0.6 +/- 2.8 min in anterior-posterior direction. The image quality of the FPDI system was sufficient to clearly reveal the radio-opaque markers on the digital image. In conclusion a FPDI system can accurately replace the Polaroid system and will facilitate daily portal alignment and true electronic IGRT verification of patient position and tumor location relative to the proton beam. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 20 条
  • [1] Application of video imaging for improvement of patient set-up
    Ploeger, LS
    Frenay, M
    Betgen, A
    de Bois, JA
    Gilhuijs, KGA
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 (03) : 277 - 284
  • [2] Development and commissioning of a set-up optimization routine for ocular proton therapy
    Elisei, G.
    Via, R.
    Pella, A.
    Calvi, G.
    Ricotti, R.
    Tagaste, B.
    Fontana, G.
    Fiore, M. R.
    Ciocca, M.
    Valvo, F.
    Baroni, G.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S96 - S97
  • [3] Analysis of the Precision of Patient Set-Up, and Fidelity of the Delivered Dose Distribution in Proton Therapy of Ocular Tumors
    Trofimov, A.
    Carpenter, K.
    Shih, H. A.
    MEDICAL PHYSICS, 2014, 41 (06) : 383 - 383
  • [4] Efficient application of megavolt imaging for patient set-up verification
    Quint, S.
    Os van, M. J. H.
    Boer de, J. C. J.
    Dirkx, M. L. P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S205 - S205
  • [5] Development and validation of a new set-up simulator dedicated to ocular proton therapy at CNAO
    Elisei, G.
    Pella, A.
    Ricotti, R.
    Via, R.
    Fiore, M. R.
    Calvi, G.
    Mastella, E.
    Paganelli, C.
    Tagaste, B.
    Bello, F.
    Fontana, G.
    Meschini, G.
    Buizza, G.
    Valvo, F.
    Orlandi, E.
    Ciocca, M.
    Baroni, G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 228 - 239
  • [6] Commissioning and evaluation of an amorphous silicon flat-panel digital Imaging system (XRD 1640, Perkin Elmer) for its application in proton beam therapy
    Nookala, P.
    Cho, J.
    Ghebremedhin, A.
    Patyal, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2016 - 2017
  • [7] CLINICAL-APPLICATION OF AN ELECTRONIC IMAGING DEVICE FOR ASSISTING PATIENT SET-UP IN RADIOTHERAPY
    WADE, JP
    NICHOLAS, D
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (763): : 596 - 602
  • [8] Patient set-up for proton radiotherapy using digital X-ray images of implanted fiducials
    Zygmanski, P
    Rosenthal, S
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 332 - 333
  • [9] Application of on-line volumetric and radiographic imaging to improve set-up in stereotactic therapy
    Oldham, M
    Letourneau, D
    Watt, L
    Wong, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1471 - 1471
  • [10] Beam set-up selection using Pareto fronts for robust proton therapy planning in cervical cancer
    Van de Schoot, A. J. A. J.
    Visser, J.
    Van Kesteren, Z.
    Janssen, T. M.
    Rasch, C. R. N.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S255 - S256