VFMA: Topographic Analysis of Sensitivity Data From Full-Field Static Perimetry

被引:53
|
作者
Weleber, Richard G. [1 ]
Smith, Travis B. [1 ]
Peters, Dawn [1 ,2 ]
Chegarnov, Elvira N. [1 ]
Gillespie, Scott P. [3 ]
Francis, Peter J. [4 ]
Gardiner, Stuart K. [5 ]
Paetzold, Jens [6 ]
Dietzsch, Janko [6 ]
Schiefer, Ulrich [6 ,7 ]
Johnson, Chris A. [8 ,9 ]
机构
[1] Oregon Hlth & Sci Univ, Oregon Retinal Degenerat Ctr, Casey Eye Inst, Portland, OR 97201 USA
[2] Oregon Hlth & Sci Univ, Dept Publ Hlth & Preventat Med, Div Biostat, Portland, OR 97201 USA
[3] Appl Brain Inc, Portland, OR USA
[4] Pacific Ophthalmol Consulting, Portland, OR USA
[5] Devers Eye Inst, Legacy Res Inst, Portland, OR USA
[6] Univ Tubingen, Ctr Ophthalmol, Inst Ophthalm Res, Tubingen, Germany
[7] Univ Appl Sci, Competence Ctr Vis Res, Aalen, Germany
[8] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[9] Univ Iowa, Inst Vis Res, Iowa City, IA USA
来源
关键词
visual fields; standard automated perimetry; retinitis pigmentosa; volumetric measures of the hill of vision; clinical trial endpoints; DOMINANT RETINITIS-PIGMENTOSA; AUTOMATED PERIMETRY; VISUAL-FIELDS; DYSTROPHY; GLAUCOMA; MUTATION; DEFECTS; SIZE; ROD;
D O I
10.1167/tvst.4.2.14
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze static visual field sensitivity with topographic models of the hill of vision (HOV), and to characterize several visual function indices derived from the HOV volume. Methods: A software application, Visual Field Modeling and Analysis (VFMA), was developed for static perimetry data visualization and analysis. Three-dimensional HOV models were generated for 16 healthy subjects and 82 retinitis pigmentosa patients. Volumetric visual function indices, which are measures of quantity and comparable regardless of perimeter test pattern, were investigated. Cross-validation, reliability, and cross-sectional analyses were performed to assess this methodology and compare the volumetric indices to conventional mean sensitivity and mean deviation. Floor effects were evaluated by computer simulation. Results: Cross-validation yielded an overall R-2 of 0.68 and index of agreement of 0.89, which were consistent among subject groups, indicating good accuracy. Volumetric and conventional indices were comparable in terms of test-retest variability and discriminability among subject groups. Simulated floor effects did not negatively impact the repeatability of any index, but large floor changes altered the discriminability for regional volumetric indices. Conclusions: VFMA is an effective tool for clinical and research analyses of static perimetry data. Topographic models of the HOV aid the visualization of field defects, and topographically derived indices quantify the magnitude and extent of visual field sensitivity. Translational Relevance: VFMA assists with the interpretation of visual field data from any perimetric device and any test location pattern. Topographic models and volumetric indices are suitable for diagnosis, monitoring of field loss, patient counseling, and endpoints in therapeutic trials.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [21] THE TOPOGRAPHIC DISTRIBUTION OF THE MAGNETIC P100M TO FULL-FIELD AND HALF-FIELD STIMULATION
    HARDING, G
    JANDAY, B
    ARMSTRONG, R
    DOCUMENTA OPHTHALMOLOGICA, 1992, 80 (01) : 63 - 73
  • [22] The full-field temporal contrast sensitivity test for glaucoma: influence of cataract
    A. G. M. Jünemann
    Folkert Kurt Horn
    Peter Martus
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 427 - 432
  • [23] Adaptive automatic data analysis in full-field fringe pattern based optical metrology
    Trusiak, Maciej
    Patorski, Krzysztof
    Sluzewski, Lukasz
    Pokorski, Krzysztof
    Sunderland, Zofia
    20TH SLOVAK-CZECH-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2016, 10142
  • [24] The full-field temporal contrast sensitivity test for glaucoma:: influence of cataract
    Jünemann, AGM
    Horn, FK
    Martus, P
    Korth, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (05) : 427 - 432
  • [25] Rapid stress analysis by means of full-field thermoelasticity
    Honlet, M
    Boyce, BR
    INSIGHT, 2001, 43 (04) : 249 - 253
  • [26] Quantitative Full-Field Data Fusion for Evaluation of Complex Structures
    J. S. Callaghan
    D. Crump
    A. S. Nielsen
    O. T. Thomsen
    J. M. Dulieu-Barton
    Experimental Mechanics, 2023, 63 : 1095 - 1115
  • [27] Shape features and finite element model updating from full-field strain data
    Wang, Weizhuo
    Mottershead, John E.
    Sebastian, Christopher M.
    Patterson, Eann A.
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2011, 48 (11-12) : 1644 - 1657
  • [28] ERROR ANALYSIS OF FULL-FIELD ASTROMETRY WITH A SCHMIDT TELESCOPE
    NAKAMURA, T
    SEKIGUCHI, M
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 1993, 45 (01) : 119 - 128
  • [29] Full-field analysis and image forces for piezoelectric bimaterials
    Ma, C. -C.
    Wu, W. -C.
    Lee, J. -M.
    ACTA MECHANICA, 2008, 195 (1-4) : 275 - 294
  • [30] Full-field analysis and image forces for piezoelectric bimaterials
    Chien-Ching Ma
    W.-C. Wu
    J.-M. Lee
    Acta Mechanica, 2008, 195 : 275 - 294