The full-field temporal contrast sensitivity test for glaucoma: influence of cataract

被引:0
|
作者
A. G. M. Jünemann
Folkert Kurt Horn
Peter Martus
Matthias Korth
机构
[1] Department of Ophthalmology,
[2] University of Erlangen-Nürnberg,undefined
[3] Schwabachanlage 6,undefined
[4] 91054 Erlangen,undefined
[5] Germany email: anselm.juenemann@augen.med.uni-erlangen.de Tel.: +49–9131–853001 Fax: +49–09131–856401,undefined
[6] Department of Medical Informatics,undefined
[7] Biometry and Epidemiology of University Erlangen-Nürnberg,undefined
[8] Waldstrasse 6,undefined
[9] 91054 Erlangen,undefined
[10] Germany,undefined
关键词
Visual Acuity; Glaucoma; Cataract; Nonparametric Test; Sensitivity Test;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose: To determine the influence of lens opacities on temporal contrast sensitivity, measured by the full-field flicker test (”Erlangen flicker test”). Methods: Thirty-six consecutive patients (mean age 71.1±11.6 years, 12 male, 24 female, refractive error –1.5±3.8 dpt) with cataract (visual acuity 0.21±0.16, retinal acuity 0.56±0.32, no glaucoma) were studied. Temporal contrast sensitivity (full-field flicker test, 37.1 Hz) and lens opacity (back scatter Lens Opacity Meter, Interzeag) were measured preoperatively and on the 3rd postoperative day. Statistics: nonparametric tests (Wilcoxon-test, Spearman correlation coefficient, Mann-Whitney U-test). Results: No significant difference was seen in temporal contrast sensitivity pre- and postoperatively, but there was a significant difference in lens opacity measurements pre- and postoperatively. No significant correlation was found between temporal contrast sensitivity and lens opacity values preoperatively and postoperatively. Conclusion: The temporal contrast sensitivity, measured by the full-field flicker test, seems to be independent of lens opacity due to the range of cataract included in this study. The data indicate that the full-field flicker test is useful for early glaucoma detection even in patients with cataract formations.
引用
下载
收藏
页码:427 / 432
页数:5
相关论文
共 50 条
  • [1] The full-field temporal contrast sensitivity test for glaucoma:: influence of cataract
    Jünemann, AGM
    Horn, FK
    Martus, P
    Korth, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (05) : 427 - 432
  • [2] The full-field temporal contrast-sensitivity test for glaucoma - Influence of cataract
    Junemann, A
    Horn, F
    Budde, WM
    Mardin, CY
    Korth, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2327 - 2327
  • [3] Temporal contrast sensitivity using full-field flicker test (Erlangen flicker test) in patients after penetrating keratoplasty
    Nhung X. Nguyen
    Folkert K. Horn
    Berthold Seitz
    Claus Cursiefen
    Peter Martus
    Achim Langenbucher
    Michael Küchle
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 443 - 447
  • [4] Temporal contrast sensitivity using full-field flicker test (Erlangen flicker test) in patients after penetrating keratoplasty
    Nguyen, NX
    Horn, FK
    Seitz, B
    Cursiefen, C
    Martus, P
    Langenbucher, A
    Küchle, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (06) : 443 - 447
  • [5] Full-field flicker sensitivity in glaucoma patients with diffuse and localized perimetric defects
    Horn, FK
    Korth, M
    Junemann, A
    Prenzel, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2643 - 2643
  • [6] The full-field flicker test in early diagnosis of chronic open-angle glaucoma
    Horn, RK
    Jonas, JB
    Korth, M
    Junemann, A
    Grundler, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (03) : 313 - 319
  • [7] The Effect of Cataract on Early Stage Glaucoma Detection Using Spatial and Temporal Contrast Sensitivity Tests
    Klein, Johann
    Pierscionek, Barbara K.
    Lauritzen, Jan
    Derntl, Karin
    Grzybowski, Andrzej
    Zlatkova, Margarita B.
    PLOS ONE, 2015, 10 (06):
  • [8] SPATIAL-TEMPORAL CONTRAST SENSITIVITY AND GLAUCOMA
    CELENTANO, MA
    TEREBUH, A
    JINDRA, LF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1108 - 1108
  • [9] The full-field flicker test in glaucomas:: influence of intraocular pressure and pattern of visual field losses
    Horn, FK
    Velten, IM
    Jünemann, A
    Korth, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (08) : 621 - 628
  • [10] The full-field flicker test in glaucomas: influence of intraocular pressure and pattern of visual field losses
    F. K. Horn
    Isabel M. Velten
    Anselm Jünemann
    Matthias Korth