The full-field temporal contrast sensitivity test for glaucoma: influence of cataract

被引:0
|
作者
A. G. M. Jünemann
Folkert Kurt Horn
Peter Martus
Matthias Korth
机构
[1] Department of Ophthalmology,
[2] University of Erlangen-Nürnberg,undefined
[3] Schwabachanlage 6,undefined
[4] 91054 Erlangen,undefined
[5] Germany email: anselm.juenemann@augen.med.uni-erlangen.de Tel.: +49–9131–853001 Fax: +49–09131–856401,undefined
[6] Department of Medical Informatics,undefined
[7] Biometry and Epidemiology of University Erlangen-Nürnberg,undefined
[8] Waldstrasse 6,undefined
[9] 91054 Erlangen,undefined
[10] Germany,undefined
关键词
Visual Acuity; Glaucoma; Cataract; Nonparametric Test; Sensitivity Test;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose: To determine the influence of lens opacities on temporal contrast sensitivity, measured by the full-field flicker test (”Erlangen flicker test”). Methods: Thirty-six consecutive patients (mean age 71.1±11.6 years, 12 male, 24 female, refractive error –1.5±3.8 dpt) with cataract (visual acuity 0.21±0.16, retinal acuity 0.56±0.32, no glaucoma) were studied. Temporal contrast sensitivity (full-field flicker test, 37.1 Hz) and lens opacity (back scatter Lens Opacity Meter, Interzeag) were measured preoperatively and on the 3rd postoperative day. Statistics: nonparametric tests (Wilcoxon-test, Spearman correlation coefficient, Mann-Whitney U-test). Results: No significant difference was seen in temporal contrast sensitivity pre- and postoperatively, but there was a significant difference in lens opacity measurements pre- and postoperatively. No significant correlation was found between temporal contrast sensitivity and lens opacity values preoperatively and postoperatively. Conclusion: The temporal contrast sensitivity, measured by the full-field flicker test, seems to be independent of lens opacity due to the range of cataract included in this study. The data indicate that the full-field flicker test is useful for early glaucoma detection even in patients with cataract formations.
引用
下载
收藏
页码:427 / 432
页数:5
相关论文
共 50 条
  • [31] Spectral characteristics of the PhNR in the full-field flash electroretinogram of normals and glaucoma patients
    Jan Kremers
    Mounira Jertila
    Barbara Link
    Gobinda Pangeni
    Folkert K. Horn
    Documenta Ophthalmologica, 2012, 124 : 79 - 90
  • [32] Spectral characteristics of the PhNR in the full-field flash electroretinogram of normals and glaucoma patients
    Kremers, Jan
    Jertila, Mounira
    Link, Barbara
    Pangeni, Gobinda
    Horn, Folkert K.
    DOCUMENTA OPHTHALMOLOGICA, 2012, 124 (02) : 79 - 90
  • [33] Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma
    Hot, Aliya
    Dul, Mitchell W.
    Swanson, William H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (07) : 3049 - 3057
  • [34] Assessment of contrast sensitivity by Spaeth Richman Contrast Sensitivity Test and Pelli Robson Chart Test in patients with varying severity of glaucoma
    Sahil Thakur
    Parul Ichhpujani
    Suresh Kumar
    Ravneet Kaur
    Sunandan Sood
    Eye, 2018, 32 : 1392 - 1400
  • [35] Assessment of contrast sensitivity by Spaeth Richman Contrast Sensitivity Test and Peli Robson Chart Test in patients with varying severity of glaucoma
    Thakur, Sahil
    Ichhpujani, Parul
    Kumar, Suresh
    Kaur, Ravneet
    Sood, Sunandan
    EYE, 2018, 32 (08) : 1392 - 1400
  • [36] CONTRAST SENSITIVITY IN TEST FIELD WITH BRIGHT SURROUND
    SCHREUDE.DA
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1965, 55 (06) : 729 - &
  • [37] Determination of normal values of full-field electroretinogram in Poodle dogs with cataract according to age
    Vaz Safatle, Angelica de Mendonca
    Lisak, Ricardo
    Otsuki, Denise Aya
    Gomes, Debora
    CIENCIA RURAL, 2010, 40 (03): : 587 - 593
  • [38] Full-field light stimuli to test perception in severe retinal degenerations
    Roman, AJ
    Aleman, TS
    Cideciyan, AV
    Chico, JD
    Schwartz, SB
    Windsor, EAM
    Smilko, EE
    Maguire, MG
    Jacobson, SG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U576 - U576
  • [39] Test-retest reliability of scotopic full-field electroretinograms in rabbits
    Luebke, Jan
    Anton, Alexandra
    Bach, Michael
    DOCUMENTA OPHTHALMOLOGICA, 2017, 134 (03) : 157 - 165
  • [40] Defocus test and defocus correction in full-field optical coherence tomography
    Labiau, S.
    David, G.
    Gigan, S.
    Boccara, A. C.
    OPTICS LETTERS, 2009, 34 (10) : 1576 - 1578