VFMA: Topographic Analysis of Sensitivity Data From Full-Field Static Perimetry

被引:53
|
作者
Weleber, Richard G. [1 ]
Smith, Travis B. [1 ]
Peters, Dawn [1 ,2 ]
Chegarnov, Elvira N. [1 ]
Gillespie, Scott P. [3 ]
Francis, Peter J. [4 ]
Gardiner, Stuart K. [5 ]
Paetzold, Jens [6 ]
Dietzsch, Janko [6 ]
Schiefer, Ulrich [6 ,7 ]
Johnson, Chris A. [8 ,9 ]
机构
[1] Oregon Hlth & Sci Univ, Oregon Retinal Degenerat Ctr, Casey Eye Inst, Portland, OR 97201 USA
[2] Oregon Hlth & Sci Univ, Dept Publ Hlth & Preventat Med, Div Biostat, Portland, OR 97201 USA
[3] Appl Brain Inc, Portland, OR USA
[4] Pacific Ophthalmol Consulting, Portland, OR USA
[5] Devers Eye Inst, Legacy Res Inst, Portland, OR USA
[6] Univ Tubingen, Ctr Ophthalmol, Inst Ophthalm Res, Tubingen, Germany
[7] Univ Appl Sci, Competence Ctr Vis Res, Aalen, Germany
[8] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[9] Univ Iowa, Inst Vis Res, Iowa City, IA USA
来源
关键词
visual fields; standard automated perimetry; retinitis pigmentosa; volumetric measures of the hill of vision; clinical trial endpoints; DOMINANT RETINITIS-PIGMENTOSA; AUTOMATED PERIMETRY; VISUAL-FIELDS; DYSTROPHY; GLAUCOMA; MUTATION; DEFECTS; SIZE; ROD;
D O I
10.1167/tvst.4.2.14
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze static visual field sensitivity with topographic models of the hill of vision (HOV), and to characterize several visual function indices derived from the HOV volume. Methods: A software application, Visual Field Modeling and Analysis (VFMA), was developed for static perimetry data visualization and analysis. Three-dimensional HOV models were generated for 16 healthy subjects and 82 retinitis pigmentosa patients. Volumetric visual function indices, which are measures of quantity and comparable regardless of perimeter test pattern, were investigated. Cross-validation, reliability, and cross-sectional analyses were performed to assess this methodology and compare the volumetric indices to conventional mean sensitivity and mean deviation. Floor effects were evaluated by computer simulation. Results: Cross-validation yielded an overall R-2 of 0.68 and index of agreement of 0.89, which were consistent among subject groups, indicating good accuracy. Volumetric and conventional indices were comparable in terms of test-retest variability and discriminability among subject groups. Simulated floor effects did not negatively impact the repeatability of any index, but large floor changes altered the discriminability for regional volumetric indices. Conclusions: VFMA is an effective tool for clinical and research analyses of static perimetry data. Topographic models of the HOV aid the visualization of field defects, and topographically derived indices quantify the magnitude and extent of visual field sensitivity. Translational Relevance: VFMA assists with the interpretation of visual field data from any perimetric device and any test location pattern. Topographic models and volumetric indices are suitable for diagnosis, monitoring of field loss, patient counseling, and endpoints in therapeutic trials.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [41] Full-field flicker sensitivity in glaucoma patients with diffuse and localized perimetric defects
    Horn, FK
    Korth, M
    Junemann, A
    Prenzel, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2643 - 2643
  • [42] Pattern Recognition Analysis Reveals Unique Contrast Sensitivity Isocontours Using Static Perimetry Thresholds Across the Visual Field
    Phu, Jack
    Khuu, Sieu K.
    Nivison-Smith, Lisa
    Zangerl, Barbara
    Choi, Agnes Yiu Jeung
    Jones, Bryan W.
    Pfeiffer, Rebecca L.
    Marc, Robert E.
    Kalloniatis, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (11) : 4863 - 4876
  • [43] Development of a full-field two-color dark-adapted perimetry protocol using an unmodified perimeter
    Huang, Samuel
    Amato, Alessia
    Schmidt, Ryan
    Tschetter, Wayne
    Igelman, Austin
    Everett, Lesley
    Yang, Paul
    Pennesi, Mark
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [44] Full-Field High-Strain Evaluation from Wrapped ESPI Data Using Phasors
    Heikkinen, Juuso
    Schajer, Gary S.
    ADVANCEMENT OF OPTICAL METHODS IN EXPERIMENTAL MECHANICS, VOL 3, 2017, : 25 - 34
  • [45] Exploratory Full-Field Strain Analysis of Regenerated Bone Tissue from Osteoinductive Biomaterials
    Fernandez, Marta Pena
    Black, Cameron
    Dawson, Jon
    Gibbs, David
    Kanczler, Janos
    Oreffo, Richard O. C.
    Tozzi, Gianluca
    MATERIALS, 2020, 13 (01) : 168
  • [46] From the thermal and kinematical full-field measurements to the analysis of deformation mechanisms of NiTi SMAs
    Schlosser, P.
    Favier, D.
    Louche, H.
    Orgeas, L.
    Liu, Y.
    ESOMAT 2009 - 8TH EUROPEAN SYMPOSIUM ON MARTENSITIC TRANSFORMATIONS, 2009,
  • [47] Sensitivity Study on High-Resolution Numerical Modeling of Static Topographic Data
    Jee, Joon-Bum
    Kim, Sangil
    ATMOSPHERE, 2016, 7 (07)
  • [48] New approaches to the full-field analysis of photoelastic stress patterns
    Buckberry, C
    Towers, D
    OPTICS AND LASERS IN ENGINEERING, 1996, 24 (5-6) : 415 - 428
  • [49] Full-field digital mammograms for breast density analysis.
    Nishino, TK
    Brunder, DG
    Khamapirad, T
    Grady, JJ
    Lu, LJW
    CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2004, 13 (11) : 1906S - 1907S
  • [50] Full-field analysis of damage under complex thermomechanical loading
    Leost, Nicolas
    Koester, Alain
    Missoum-Benziane, Djamel
    Rambaudon, Matthieu
    Cameriano, Laurent
    Comte, Francois
    Le Pannerer, Brice
    Maurel, Vincent
    INTERNATIONAL JOURNAL OF FATIGUE, 2023, 170