Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities

被引:103
|
作者
Ben-David, Tom [1 ]
Waring, Michael S. [1 ]
机构
[1] Drexel Univ, Civil Architectural & Environm Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
Natural ventilation; Particulate matter; Filtration; Indoor outdoor (I/O) ratio; Mechanical economizing; SECONDARY ORGANIC AEROSOL; CO2; CONCENTRATIONS; DAILY MORTALITY; EXPOSURE; OZONE; HEALTH; PARTICULATE; FILTRATION; BUILDINGS; POLLUTION;
D O I
10.1016/j.buildenv.2016.05.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study simulated the impacts of natural versus mechanical ventilation in offices on indoor concentrations of key pollutants, as well as energy usage. A typical office building was modeled in EnergyPlus in fourteen U.S. cities to assess the energy use and airflows delivered by an ideal variable air volume (VAV) system in a range of climates. Two mechanical ventilation strategies (minimum; minimum + economizer control) were modeled, as well as two analogous natural ventilation strategies, which used a fan-driven recirculation hybrid system to maintain setpoints if necessary. Outputted hourly ventilation, recirculation, and infiltration rates were used in an indoor air model with city specific outdoor monitoring data to compute indoor concentrations of carbon monoxide, carbon dioxide, formaldehyde, nitrogen dioxide, ozone, and fine particles (PM2.5). Natural ventilation decreased energy use, due to a wider temperature setpoint band for natural ventilation scenarios and somewhat lower fan energy use. Indoor concentrations and indoor/outdoor (I/O) ratios of all pollutants were similar for analogous strategies, except PM2.5, which was reduced by filtration in the supply air. Median PM2.5 I/O ratios were a factor of 1.2, 2.2, and 6.3 larger for natural versus mechanical ventilation strategies with MERV 8, 11, and 16 filters, respectively. The filtration impact was so strong that PM2,5 I/O ratios differed little between mechanical minimum and economizing strategies, especially as filter efficiency increased. These results can be used to understand tradeoffs of energy and indoor air pollution trends of natural versus mechanical ventilation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:320 / 336
页数:17
相关论文
共 50 条
  • [1] Modeling impacts of dynamic ventilation strategies on indoor air quality of offices in six US cities
    Rackes, Adams
    Waring, Michael S.
    BUILDING AND ENVIRONMENT, 2013, 60 : 243 - 253
  • [2] NATURAL VENTILATION FOR AMPHITHEATRES - A WAY OF INCREASING INDOOR AIR QUALITY BY DECREASING ENERGY CONSUMPTION
    Hornet, M.
    Cirstolovean, I. L.
    Nastac, D. C.
    Todor, R.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2020, 21 (01): : 10 - 18
  • [3] Natural and Mechanical Ventilation of Classrooms, Compared in Terms of Air Quality and Energy Consumption.
    Rigos, Efstratios
    Amonn, Wido
    Klima, Kalte, Heizung, 1988, 16 (05): : 232 - 235
  • [4] Energy and indoor air quality implications of alternative minimum ventilation rates in California offices
    Dutton, Spencer M.
    Fisk, William J.
    Building and Environment, 2014, 82 : 121 - 127
  • [5] Energy and indoor air quality implications of alternative minimum ventilation rates in California offices
    Dutton, Spencer M.
    Fisk, William J.
    BUILDING AND ENVIRONMENT, 2014, 82 : 121 - 127
  • [6] Energy and indoor air quality implications of alternative minimum ventilation rates in California offices
    Dutton, Spencer M.
    Fisk, William J.
    Building and Environment, 2014, 82 : 121 - 127
  • [7] An energy impact assessment of indoor air quality acceptance for air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    Hui, P. S.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2815 - 2819
  • [8] HOW VENTILATION INFLUENCES ENERGY CONSUMPTION AND INDOOR AIR QUALITY.
    Woods, James E.
    Maldonado, Eduardo A.B.
    Reynolds, Gary L.
    ASHRAE Journal, 1981, 23 (09) : 40 - 43
  • [9] Maintaining an acceptable indoor air quality of spaces by intentional natural ventilation or intermittent mechanical ventilation with minimum energy use
    Su, Wei
    Ai, Zhengtao
    Liu, Jing
    Yang, Bin
    Wang, Faming
    APPLIED ENERGY, 2023, 348
  • [10] Numerical analysis on mechanical ventilation impact on indoor air quality in a basement
    Anyaegbuna, Benjamin E.
    Onokwai, Anthony O.
    Anyaegbuna, Ndubueze T.
    Iweriolor, Sunday
    Anyaegbuna, Ikechukwu D.
    Adegun, Isaac K.
    Fayomi, Ojo S.
    Ighravwe, Desmond E.
    Onifade, Morakinyo K.
    SCIENTIFIC AFRICAN, 2024, 25