Maintaining an acceptable indoor air quality of spaces by intentional natural ventilation or intermittent mechanical ventilation with minimum energy use

被引:10
|
作者
Su, Wei [1 ]
Ai, Zhengtao [1 ]
Liu, Jing [1 ]
Yang, Bin [2 ]
Wang, Faming [3 ]
机构
[1] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Energy, Changsha, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, Leuven, Belgium
关键词
IAQ; Ventilation frequency; Ventilation duration; Air change rate per hour; Energy use; CONDITIONED RESIDENTIAL BUILDINGS; MODEL; PERFORMANCE; IAQ; CO2;
D O I
10.1016/j.apenergy.2023.121504
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ventilation is essential for maintaining good indoor air quality (IAQ). However, many buildings continue to suffer from inadequate ventilation due to a lack of either sufficient natural ventilation or proper operation of mechanical ventilation. During the pandemic of COVID-19, several Chinese guidelines have suggested that the household rooms for isolating infected persons and the classrooms that are not equipped with mechanical ventilation should open the windows for at least 30 min twice a day. This study first investigated whether this way of natural ventilation could ensure an acceptable IAQ. Then, the relationships between ventilation duration, ventilation frequency, and IAQ under different air change rates per hour (ACH) were examined to understand how to optimize ventilation design and operation in an efficient manner. When the ACH is & GE; 6 h- 1, an acceptable IAQ can be achieved under the recommended ventilation frequency. An increase in ACH would improve the IAQ and reduce the IAQ difference caused by different CO2 generation rate per unit volume (Gr/V) values. Furthermore, simply increasing single ventilation duration while maintaining constant ventilation frequency is not an effective way to improve IAQ, as the improvement decreases as the ventilation duration is increased. Finally, when total ventilation duration is constant, increasing ventilation frequency can significantly improve the ventilation efficiency and thus IAQ, laying the groundwork for ventilation design that balances IAQ and energy use. The findings provide feasible and economical solutions for ventilation of buildings where conven-tional mechanical ventilation systems are not affordable.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Efficacy of intermittent ventilation for providing acceptable indoor air quality
    Sherman, Max H.
    [J]. ASHRAE Transactions 2006, Vol 112, Pt 1, 2006, 112 : 93 - 101
  • [2] Ventilation for acceptable indoor air quality
    [J]. ASHRAE Standard, 2007, (62.1-2007): : 1 - 41
  • [3] Ventilation for acceptable indoor air quality
    [J]. ASHRAE Standard, 2004, (62.1):
  • [4] VENTILATION FOR ACCEPTABLE INDOOR AIR-QUALITY
    JANSSEN, JE
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1989, 31 (10): : 40 - &
  • [5] ASHRAE Standard: Ventilation for Acceptable Indoor Air Quality
    [J]. ASHRAE Standard, 2002, (62-2001):
  • [6] Exploring the adequacy of mechanical ventilation for acceptable indoor air quality in office buildings
    Abuimara, Tareq
    Hobson, Brodie W.
    Gunay, Burak
    O'Brien, William
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (02) : 275 - 288
  • [7] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    [J]. ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1983, 177 (06): : 571 - 571
  • [8] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    [J]. ENVIRONMENT INTERNATIONAL, 1983, 9 (02) : 153 - 156
  • [9] Intermittent demand-controlled ventilation for energy flexibility and indoor air quality
    Niu, Dun
    Li, Yuxin
    Zhang, Sheng
    Lin, Zhang
    [J]. BUILDING AND ENVIRONMENT, 2024, 263
  • [10] Ventilation Control Approach for Acceptable Indoor Air Quality and Enhancing Energy Saving In Thailand
    Boonyayothin, Vorakamol
    Hirunlabh, Jongjit
    Khummongkol, Pojanie
    Teekasap, Sombat
    Shin, U-Cheul
    Khedari, Joseph
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2011, 9 (04) : 315 - 326