Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique

被引:13
|
作者
Maki, Satoshi [1 ]
Aramomi, Masaaki [2 ]
Matsuura, Yusuke [1 ]
Furuya, Takeo [1 ]
Ota, Mitsutoshi [1 ]
Iijima, Yasushi [1 ]
Saito, Junya [1 ]
Suzuki, Takane [1 ]
Mannoji, Chikato [2 ]
Takahashi, Kazuhisa [1 ]
Yamazaki, Masashi [3 ]
Koda, Masao [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Orthopaed Surg, Chiba, Japan
[2] Teikyo Univ, Chiba Med Ctr, Dept Orthopaed Surg, Ichihara, Chiba, Japan
[3] Univ Tsukuba, Fac Med, Dept Orthopaed Surg, Tsukuba, Ibaraki, Japan
关键词
paravertebral foramen screw; lateral mass screw; pedicle screw; biomechanical study; pullout strength; cervical spine; surgical technique; LATERAL MASS FIXATION; BONE-MINERAL DENSITY; PULL-OUT STRENGTH; PEDICLE SCREWS; CEMENT AUGMENTATION; STABILIZATION; COMPLICATIONS; INSERTION; ANGIOGRAPHY; STABILITY;
D O I
10.3171/2016.12.SPINE16803
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Fusion surgery with instrumentation is a widely accepted treatment for cervical spine pathologies. The authors propose a novel technique for subaxial cervical fusion surgery using paravertebral foramen screws (PVFS). The authors consider that PVFS have equal or greater biomechanical strength than lateral mass screws (LMS). The authors' goals of this study were to conduct a biomechanical study of PVFS, to investigate the suitability of PVFS as salvage fixation for failed LMS, and to describe this novel technique. METHODS The authors harvested 24 human cervical spine vertebrae (C3-6) from 6 fresh -frozen cadaver specimens from donors whose mean age was 84.3 +/- 10.4 years at death. For each vertebra, one side was chosen randomly for PVFS and the other for LMS. For PVFS, a 3.2-mm drill with a stopper was advanced under lateral fluoroscopic imaging. The drill stopper was set to 12 mm, which was considered sufficiently short not to breach the transverse foramen. The drill was directed from 20 degrees to 25 degrees medially so that the screw could purchase the relatively hard cancellous bone around the entry zone of the pedicle. The hole was tapped and a 4.5-mm-diameter x 12-mm screw was inserted. For LMS, 3.5-mm-diameter x 14-mm screws were inserted into the lateral mass of C3-6. The pullout strength of each screw was measured. After pullout testing of LMS, a drill was inserted into the screw hole and the superior cortex of the lateral mass was pried to cause a fracture through the screw hole, simulating intraoperative fracture of the lateral mass. After the procedure, PVFS for salvage (sPVFS) were inserted on the same side and pullout strength was measured. RESULTS The CT scans obtained after screw insertion revealed no sign of pedicle breaching, violation of the transverse foramen, or fracture of the lateral mass. A total of 69 screws were tested (23 PVFS, 23 LMS, and 23 sPVFS). One vertebra was not used because of a fracture that occurred while the specimen was prepared. The mean bone mineral density of the specimens was 0.29 0.10 g/cm3. The mean pullout strength was 234 +/- 114 N for PVFS, 158 +/- 91 N for LMS, and 195 +/- 125 N for sPVFS. The pullout strength for PVFS tended to be greater than that for LMS. However, the difference was not quite significant (p = 0.06). CONCLUSIONS The authors introduce a novel fixation technique for the subaxial cervical spine. This study suggests that PVFS tend to provide stronger fixation than LMS for initial applications and fixation equal to LMS for salvage applications. If placement of LMS fails, PVFS can serve as a salvage fixation technique.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [41] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Lehmann, W
    Blauth, M
    Briem, D
    Schmidt, U
    EUROPEAN SPINE JOURNAL, 2004, 13 (01) : 69 - 75
  • [42] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Wolfgang Lehmann
    Michael Blauth
    Daniel Briem
    Ulf Schmidt
    European Spine Journal, 2004, 13 : 69 - 75
  • [43] Biomechanical evaluation of posterior screw fixation in cadaveric cervical spines (June, pg 13, 2003)
    Pupagelopoulos, PJ
    Currier, BL
    Neale, PG
    Hokari, Y
    Berglund, LJ
    Larson, DR
    Fisher, DR
    An, KN
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) : 347 - 347
  • [44] Biomechanical study of the lumbar spine using a unilateral pedicle screw fixation system
    Kasai, Yuichi
    Inaba, Tadashi
    Kato, Takaya
    Matsumura, Yoshihiro
    Akeda, Koji
    Uchida, Atsumasa
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (03) : 364 - 367
  • [45] Pedicle screw fixation of the thoracic spine:: An in vitro biomechanical study on different configurations
    Deviren, V
    Acaroglu, E
    Lee, J
    Fujita, M
    Hu, S
    Lenke, LG
    Polly, D
    Kuklo, TR
    O'Brien, M
    Brumfield, D
    Puttlitz, CM
    SPINE, 2005, 30 (22) : 2530 - 2537
  • [46] Treatment of Upper Cervical Spine Instability with Posterior Fusion Plus Atlantoaxial Pedicle Screw
    Ma, Chao
    Wu, Jibin
    Zhao, Meng
    Dai, Weixiang
    Wu, Dehui
    Wang, Zhaohong
    Feng, Jie
    Liu, Chao
    Li, Yiming
    Zhao, Qinghua
    Tian, Jiwei
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2014, 69 (03) : 693 - 697
  • [47] Treatment of Upper Cervical Spine Instability with Posterior Fusion Plus Atlantoaxial Pedicle Screw
    Chao Ma
    Jibin Wu
    Meng Zhao
    Weixiang Dai
    Dehui Wu
    Zhaohong Wang
    Jie Feng
    Chao Liu
    Yiming Li
    Qinghua Zhao
    Jiwei Tian
    Cell Biochemistry and Biophysics, 2014, 69 : 693 - 697
  • [48] A biomechanical study of standard posterior pelvic ring fixation versus a posterior pedicle screw construct
    Vigdorchik, Jonathan M.
    Jin, Xin
    Sethi, Anil
    Herzog, Darren T.
    Oliphant, Bryant W.
    Yang, King H.
    Vaidya, Rahul
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (08): : 1491 - 1496
  • [49] ANATOMIC AND BIOMECHANICAL STUDY OF POSTERIOR CERVICAL-SPINE PLATE ARTHRODESIS - AN EVALUATION OF 2 DIFFERENT TECHNIQUES OF SCREW PLACEMENT
    MONTESANO, PX
    JAUCH, E
    JONSSON, H
    JOURNAL OF SPINAL DISORDERS, 1992, 5 (03): : 301 - 305
  • [50] Comments on "Posterior Subaxial Cervical Spine Screw Fixation: A Review of Techniques" by Joaquim et al
    Diez-Ulloa, Maximo-Alberto
    GLOBAL SPINE JOURNAL, 2020, 10 (02) : 240 - 240