Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique

被引:13
|
作者
Maki, Satoshi [1 ]
Aramomi, Masaaki [2 ]
Matsuura, Yusuke [1 ]
Furuya, Takeo [1 ]
Ota, Mitsutoshi [1 ]
Iijima, Yasushi [1 ]
Saito, Junya [1 ]
Suzuki, Takane [1 ]
Mannoji, Chikato [2 ]
Takahashi, Kazuhisa [1 ]
Yamazaki, Masashi [3 ]
Koda, Masao [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Orthopaed Surg, Chiba, Japan
[2] Teikyo Univ, Chiba Med Ctr, Dept Orthopaed Surg, Ichihara, Chiba, Japan
[3] Univ Tsukuba, Fac Med, Dept Orthopaed Surg, Tsukuba, Ibaraki, Japan
关键词
paravertebral foramen screw; lateral mass screw; pedicle screw; biomechanical study; pullout strength; cervical spine; surgical technique; LATERAL MASS FIXATION; BONE-MINERAL DENSITY; PULL-OUT STRENGTH; PEDICLE SCREWS; CEMENT AUGMENTATION; STABILIZATION; COMPLICATIONS; INSERTION; ANGIOGRAPHY; STABILITY;
D O I
10.3171/2016.12.SPINE16803
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Fusion surgery with instrumentation is a widely accepted treatment for cervical spine pathologies. The authors propose a novel technique for subaxial cervical fusion surgery using paravertebral foramen screws (PVFS). The authors consider that PVFS have equal or greater biomechanical strength than lateral mass screws (LMS). The authors' goals of this study were to conduct a biomechanical study of PVFS, to investigate the suitability of PVFS as salvage fixation for failed LMS, and to describe this novel technique. METHODS The authors harvested 24 human cervical spine vertebrae (C3-6) from 6 fresh -frozen cadaver specimens from donors whose mean age was 84.3 +/- 10.4 years at death. For each vertebra, one side was chosen randomly for PVFS and the other for LMS. For PVFS, a 3.2-mm drill with a stopper was advanced under lateral fluoroscopic imaging. The drill stopper was set to 12 mm, which was considered sufficiently short not to breach the transverse foramen. The drill was directed from 20 degrees to 25 degrees medially so that the screw could purchase the relatively hard cancellous bone around the entry zone of the pedicle. The hole was tapped and a 4.5-mm-diameter x 12-mm screw was inserted. For LMS, 3.5-mm-diameter x 14-mm screws were inserted into the lateral mass of C3-6. The pullout strength of each screw was measured. After pullout testing of LMS, a drill was inserted into the screw hole and the superior cortex of the lateral mass was pried to cause a fracture through the screw hole, simulating intraoperative fracture of the lateral mass. After the procedure, PVFS for salvage (sPVFS) were inserted on the same side and pullout strength was measured. RESULTS The CT scans obtained after screw insertion revealed no sign of pedicle breaching, violation of the transverse foramen, or fracture of the lateral mass. A total of 69 screws were tested (23 PVFS, 23 LMS, and 23 sPVFS). One vertebra was not used because of a fracture that occurred while the specimen was prepared. The mean bone mineral density of the specimens was 0.29 0.10 g/cm3. The mean pullout strength was 234 +/- 114 N for PVFS, 158 +/- 91 N for LMS, and 195 +/- 125 N for sPVFS. The pullout strength for PVFS tended to be greater than that for LMS. However, the difference was not quite significant (p = 0.06). CONCLUSIONS The authors introduce a novel fixation technique for the subaxial cervical spine. This study suggests that PVFS tend to provide stronger fixation than LMS for initial applications and fixation equal to LMS for salvage applications. If placement of LMS fails, PVFS can serve as a salvage fixation technique.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [31] The potential biomechanical advantage of lag by technique screw fixation of the posterior pelvic ring
    Maher, Michael
    Baldini, Todd H.
    Parry, Joshua A.
    Mauffrey, Cyril
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (06): : 1045 - 1048
  • [32] Anterior Atlantooccipital Transarticular Screw Fixation A Cadaveric Study and Description of a Novel Technique
    Ji, Wei
    Xu, Xiaolin
    Liu, Qi
    Lin, Junyu
    Huang, Zucheng
    Chen, Jianting
    Zhu, Qingan
    SPINE, 2019, 44 (17) : E1010 - E1017
  • [33] Comparative In Vitro Biomechanical Analysis of a Novel Posterior Cervical Fixation Technique Versus Conventional Posterior-based Constructs
    Molina, Camilo
    Kretzer, Ryan M.
    Hu, Nianbin
    Umekoji, Hidemasa
    Cunningham, Bryan W.
    Serhan, Hassan
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (01): : 40 - 47
  • [34] Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases
    李雷
    周凤华
    王欢
    崔少千
    中华创伤杂志(英文版), 2008, (06)
  • [35] Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases
    Li Lei
    Zhou Feng-hua
    Wang Huan
    Cui Shao-qian
    CHINESE JOURNAL OF TRAUMATOLOGY, 2008, 11 (06) : 323 - 328
  • [36] Hybrid lateral mass screw sublaminar wire construct: A salvage technique for posterior cervical fixation in pediatric spine surgery
    Quinn, John C.
    Patel, Nitesh V.
    Tyagi, Rachana
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 25 : 118 - 121
  • [37] The C2 "Parsicle" Screw Introduction of a Novel Posterior Surgical Technique For Upper Cervical Fixation
    Kepler, Christopher C.
    Fang Taolin
    Bronson, Wesley H.
    Russo, Glenn S.
    Schroeder, Gregory D.
    CLINICAL SPINE SURGERY, 2020, 33 (04): : 146 - 149
  • [38] Early complications of posterior rod-screw fixation of the cervical and upper thoracic spine
    Deen, H. Gordon
    Nottmeier, Eric W.
    Reimer, Ronald
    NEUROSURGERY, 2006, 59 (05) : 1062 - 1067
  • [39] POSTERIOR INTERNAL-FIXATION WITH SCREW PLATES IN TRAUMATIC LESIONS OF THE CERVICAL-SPINE
    NAZARIAN, SM
    LOUIS, RP
    SPINE, 1991, 16 (03) : S64 - S71
  • [40] Enhancing Pedicle Screw Fixation in the Aging Spine With a Novel Bioactive Bone Cement An In Vitro Biomechanical Study
    Zhu, Qingan
    Kingwell, Stephen
    Li, Zhaoyang
    Pan, Haobo
    Lu, William W.
    Oxland, Thomas R.
    SPINE, 2012, 37 (17) : E1030 - E1037