Assessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators

被引:3
|
作者
Rostampour, N. [1 ]
Jafari, S. [2 ]
Saeb, M. [3 ]
Keshtkar, M. [4 ]
Shokrani, P. [5 ]
Ahnasi, T. [1 ]
机构
[1] Kermanshah Univ Med Sci, Dept Med Phys, Kermanshah, Iran
[2] Hamadan Univ Med Sci, Dept Radiol, Hamadan, Iran
[3] Isfahan Univ Med Sci, Seyed Al Shohada Hosp, Dept Radiat Oncol, Esfahan, Iran
[4] Gonabad Univ Med Sci, Fac Med, Dept Med Phys & Radiol, Gonabad, Iran
[5] Isfahan Univ Med Sci, Dept Med Phys, Esfahan, Iran
来源
关键词
Skyshine; shielding; radiation measurement; radiation protection; radiotherapy; scattering; medical accelerator; ROOF;
D O I
10.18869/acadpub.ijrr.16.4.499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180 degrees gantry position), with a maximum photon field size (40 x 40 cm2) at the isocenter. Measurements were obtained around the external points selected outside the room facilities at a horizontal distance from the target by the calibrated RDS-110 survey meter at four points around the isocenter. Results: The measured values of the skyshine photon exposure rates at four points for 9 MV and 18 MV were 0.6, 0.5, 0.5, and 0.4 mu Sv/h, and 0.6, 0.4, 0.4, and 0.5 mu Sv/h, respectively. All the measured skyshine photon exposure rates were lower than the values recommended by NCRP 147. Conclusion: There is a poor agreement between the measured and the calculated values; therefore it seems that caution is needed while using the equations available in NCRP 147 or 151.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 50 条
  • [31] Neutron dose measurement in Intensity Modulated Radiotherapy of 18 MV photon beams
    Chern, SS
    Selvaraj, RN
    Sheetz, M
    Wu, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1267 - 1268
  • [32] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Asghar Mesbahi
    Farshad Seyed Nejad
    Radiation Medicine, 2008, 26 : 331 - 336
  • [33] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Nejad, Farshad Seyed
    RADIATION MEDICINE, 2008, 26 (06): : 331 - 336
  • [34] Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators
    Cho, SH
    Vassiliev, ON
    Lee, S
    Liu, HH
    MEDICAL PHYSICS, 2005, 32 (01) : 137 - 148
  • [35] Preliminary results from anisotropic analytical algorithm for photon dose calculation on Siemens and Elekta linear accelerators
    Cozzi, L.
    Glashoerster, M.
    Nicolini, G.
    Seelentag, W.
    Fogliata, A.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S30 - S30
  • [36] PROPERTIES OF THE 18-MV PHOTON-BEAM FROM A DUAL ENERGY LINEAR-ACCELERATOR
    JOHNSON, DA
    IKORO, NC
    CHANG, CH
    SCARBROUGH, EC
    ANTICH, PP
    MEDICAL PHYSICS, 1987, 14 (06) : 1071 - 1078
  • [37] Investigation and modelling of the surface dose from linear accelerator produced 6 and 10 MV photon beams
    Lamb, A
    Blake, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05): : 1133 - 1146
  • [38] A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane
    P. Lonski
    M. L. Taylor
    R. D. Franich
    T. Kron
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 15 - 23
  • [39] Measurements of secondary neutron dose from 15 MV and 18 MV IMRT
    Howell, RM
    Ferenci, MS
    Hertel, NE
    Fullerton, GD
    Fox, T
    Davis, LW
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 508 - 512
  • [40] A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane
    Lonski, P.
    Taylor, M. L.
    Franich, R. D.
    Kron, T.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (01) : 15 - 23