Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators

被引:59
|
作者
Cho, SH [1 ]
Vassiliev, ON [1 ]
Lee, S [1 ]
Liu, HH [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
reference photon dosimetry data; reference phase space data; 6 MV photon beam; Monte Carlo calculations;
D O I
10.1118/1.1829172
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current study presents the reference photon dosimetry data (RPDD) and reference phase space data (RPSD) for the 6 MV photon beam from Varian 2100 series linear accelerators. The RPDD provide the basic photon dosimetry data, typically collected during the initial commissioning of a new linear accelerator, including output factors, depth dose data, and beam profile data in air and in water. The RPSD provide the full phase space information, such as position, direction, and energy for each particle generated inside the head of any particular linear accelerator in question. The dosimetric characteristics of the 6 MV photon beam from the majority of the aforementioned accelerators, which are unaltered from the manufacturer's original specifications, can be fully described with these two data sets within a clinically acceptable uncertainty (similar to +/-2%). The current study also presents a detailed procedure to establish the RPDD and RPSD using measured data and Monte Carlo calculations. The RPDD were constructed by compiling our own measured data and the average data based on the analysis of more than 50 sets of measured data from the Radiological Physics Center (RPC) and 10 sets of clinical dosimetry data obtained from 10 different institutions participating in the RPC's quality assurance monitoring program. All the measured data from the RPC and the RPC-monitored institutions were found to be within a statistically tight range (i.e., 1sigma approximate to 1% or less) for each dosimetric quantity. The manufacturer's standard data, except for in-air off-axis factors that are available only from the current study, were compared with the RPDD, showing that the manufacturer's standard data could also be used as the RPDD for the photon beam studied in this study. The RPSD were obtained from Monte Carlo calculations using the BEAmnrc/ DOSXYZnrc code system with 6.2 MeV (a spread of 3% full width at half maximum) and 1.0 mm full width at half maximum as the values of the energy and radial spread of a Gaussian electron pencil beam incident on the target, respectively. The RPSD were capable of generating Monte Carlo data that agreed with the RPDD within the acceptance criteria adopted in the current study (e.g., 1% or 1 mm for depth dose). A complete set of the RPDD and RPSD from the current study is available from the RPC website (http://rpc.mdanderson.org) or via mass storage media such as DVD or CD-ROM upon request. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 50 条
  • [1] Collection and analysis of photon beam data for Varian C-series linear accelerators: a potential reference beam data set
    Tanaka, Yoshihiro
    Mizuno, Hirokazu
    Akino, Yuichi
    Isono, Masaru
    Masai, Norihisa
    Uta, Erika
    Yamamoto, Toshijiro
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (03) : 889 - 901
  • [2] Collection and analysis of photon beam data for Varian C-series linear accelerators: a potential reference beam data set
    Yoshihiro Tanaka
    Hirokazu Mizuno
    Yuichi Akino
    Masaru Isono
    Norihisa Masai
    Erika Uta
    Toshijiro Yamamoto
    Physical and Engineering Sciences in Medicine, 2020, 43 : 889 - 901
  • [3] Percentage Depth Dose Comparative Study of 6 MV Photon Beam of Both Linear Accelerators Varian Clinac 2100 and Varian Clinac 2300 Using Gamma Index Method and Investigation of the Varian Technology
    Bencheikh, Mohamed
    Lamrabet, Abdesslam
    Didi, Abdessamad
    Maghnouj, Abdelmajid
    Tajmouati, Jaouad
    MOROCCAN JOURNAL OF CHEMISTRY, 2016, 4 (03): : 722 - 730
  • [4] COMPARISON OF PHOTON BEAM DATA AND BEAM MODELING RESULTS FOR TRUEBEAM, TRILOGY AND CLINAC 2100 LINEAR ACCELERATORS
    Beyer, G.
    Pursley, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S547 - S548
  • [5] Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators
    Beyer, Gloria P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 273 - 288
  • [6] Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data
    Kerns, James R.
    Followill, David S.
    Lowenstein, Jessica
    Molineu, Andrea
    Alvarez, Paola
    Taylor, Paige A.
    Stingo, Francesco C.
    Kry, Stephen F.
    MEDICAL PHYSICS, 2016, 43 (05) : 2374 - 2386
  • [7] BEAM DATA MEASUREMENTS FOR DYNAMIC WEDGES ON VARIAN-600C (6 MV) AND VARIAN-2100C (6 AND 10 MV) LINEAR ACCELERATORS
    BIDMEAD, AM
    GARTON, AJ
    CHILDS, PJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (03): : 393 - 411
  • [8] Validation of Monte Carlo simulation of 6 MV photon beam produced by Varian Clinac 2100 linear accelerator using BEAMnrc code and DOSXYZnrc code
    Bencheikh M.
    Maghnouj A.
    Tajmouati J.
    Didi A.
    Ezzati A.O.
    Physics of Particles and Nuclei Letters, 2017, 14 (5) : 780 - 787
  • [9] Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
    Yani, S.
    Rhani, M. F.
    Soh, R. C. X.
    Haryanto, F.
    Arif, I.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 275 - +
  • [10] Commissioning of a Varian Clinac iX 6 MV Photon Beam using Monte Carlo Simulation
    Dirgayussa, I. Gde Eka
    Yani, Sitti
    Rhani, M. Fahdillah
    Haryanto, Freddy
    5TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES (ICMNS 2014), 2015, 1677