Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators

被引:59
|
作者
Cho, SH [1 ]
Vassiliev, ON [1 ]
Lee, S [1 ]
Liu, HH [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
reference photon dosimetry data; reference phase space data; 6 MV photon beam; Monte Carlo calculations;
D O I
10.1118/1.1829172
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current study presents the reference photon dosimetry data (RPDD) and reference phase space data (RPSD) for the 6 MV photon beam from Varian 2100 series linear accelerators. The RPDD provide the basic photon dosimetry data, typically collected during the initial commissioning of a new linear accelerator, including output factors, depth dose data, and beam profile data in air and in water. The RPSD provide the full phase space information, such as position, direction, and energy for each particle generated inside the head of any particular linear accelerator in question. The dosimetric characteristics of the 6 MV photon beam from the majority of the aforementioned accelerators, which are unaltered from the manufacturer's original specifications, can be fully described with these two data sets within a clinically acceptable uncertainty (similar to +/-2%). The current study also presents a detailed procedure to establish the RPDD and RPSD using measured data and Monte Carlo calculations. The RPDD were constructed by compiling our own measured data and the average data based on the analysis of more than 50 sets of measured data from the Radiological Physics Center (RPC) and 10 sets of clinical dosimetry data obtained from 10 different institutions participating in the RPC's quality assurance monitoring program. All the measured data from the RPC and the RPC-monitored institutions were found to be within a statistically tight range (i.e., 1sigma approximate to 1% or less) for each dosimetric quantity. The manufacturer's standard data, except for in-air off-axis factors that are available only from the current study, were compared with the RPDD, showing that the manufacturer's standard data could also be used as the RPDD for the photon beam studied in this study. The RPSD were obtained from Monte Carlo calculations using the BEAmnrc/ DOSXYZnrc code system with 6.2 MeV (a spread of 3% full width at half maximum) and 1.0 mm full width at half maximum as the values of the energy and radial spread of a Gaussian electron pencil beam incident on the target, respectively. The RPSD were capable of generating Monte Carlo data that agreed with the RPDD within the acceptance criteria adopted in the current study (e.g., 1% or 1 mm for depth dose). A complete set of the RPDD and RPSD from the current study is available from the RPC website (http://rpc.mdanderson.org) or via mass storage media such as DVD or CD-ROM upon request. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 50 条
  • [21] The Effect of Voxel Size on Dose Distribution in Varian Clinac iX 6 MV Photon Beam Using Monte Carlo Simulation
    Yani, Sitti
    Dirgayussa, I. Gde E.
    Rhani, Moh Fadhillah
    Haryanto, Freddy
    Arif, Idam
    5TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES (ICMNS 2014), 2015, 1677
  • [22] A comparison of the basic photon and electron dosimetry data for Neptun IOPC linear accelerators
    Shokrani, Parvaneh
    Monadi, Shahram
    NUKLEONIKA, 2008, 53 (04) : 181 - 185
  • [23] Skyshine photon doses from 6 and 10 MV medical linear accelerators
    de Paiva, Eduardo
    da Rosa, Luiz A. R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 215 - 219
  • [24] MATCHING THE 6-MV PHOTON-BEAM CHARACTERISTICS OF 2 DISSIMILAR LINEAR ACCELERATORS
    MARSHALL, MG
    MEDICAL PHYSICS, 1993, 20 (06) : 1743 - 1746
  • [25] Accuracy of Monte Carlo software PRIMO against a reference dosimetry dataset for 6 MV photon beams
    Hermida-Lopez, M.
    Sanchez-Artunedo, D.
    Calvo-Ortega, J. F.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S938 - S939
  • [26] A full quantitative analysis of 18 MV photon beam from 2100 C/D-Varian clinical linear accelerator with and without flattening filter
    Mahdavi, S. R.
    Ay, M. R.
    Zabihzadeh, M.
    Allahverdi, M.
    Shahriari, M.
    Hoseini-Ghahfarokhi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (01): : 137 - 146
  • [27] CLINAC-18 LINEAR-ACCELERATOR - 10-MEV PHOTON-BEAM DATA
    BAHR, R
    NUSSLIN, F
    STRAHLENTHERAPIE, 1979, 155 (07) : 481 - 485
  • [28] Dosimetric Evaluation of Indigenous Farmer Type Chamber FAR65-GB for Reference Dosimetry of FFF MV Photon Beam
    Patwe, P.
    Mhatre, V.
    Dandekar, P.
    MEDICAL PHYSICS, 2016, 43 (06) : 3569 - 3569
  • [29] Monte Carlo correction factors in non reference conditions:: Buildup regions of a 6MV photon beam
    Pena, J
    Sánchez-Doblado, F
    Capote-Noy, R
    Terrón, JA
    Gómez, F
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S148 - S148
  • [30] Percent Depth Dose Comparison Between Measurements from Three Varian Linear Accelerators and Varian AAA Golden Beam Data
    Wu, G.
    Courlas, G.
    Lewis, D.
    Jackson, B.
    MEDICAL PHYSICS, 2011, 38 (06)