Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography-Multiple-Reaction-Monitoring Mass Spectrometry

被引:134
|
作者
Agger, Sean A. [1 ]
Marney, Luke C. [1 ]
Hoofnagle, Andrew N. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Lab Med, Seattle, WA 98195 USA
关键词
PEPTIDE IMMUNOAFFINITY ENRICHMENT; QUANTITATION; PROTEIN; PROTEOMICS; BIOMARKER; SERUM; RISK; LIPOPROTEINS; MORTALITY; STANDARDS;
D O I
10.1373/clinchem.2010.152264
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: If liquid-chromatography-multiple-reaction-monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed amultiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS: We used Peptide Atlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS: We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 x immunoassay - 36.6; S-x ' y = 10.3 for apoA-I and LC-MRM/MS = 1.21 x immunoassay + 7.0; S-x ' y = 7.9 for apoB). CONCLUSIONS: Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:1804 / 1813
页数:10
相关论文
共 50 条
  • [41] Simultaneous Quantification of Eleven Thiopurine Nucleotides by Liquid Chromatography-Tandem Mass Spectrometry
    Hofmann, Ute
    Heinkele, Georg
    Angelberger, Sieglinde
    Schaeffeler, Elke
    Lichtenberger, Cornelia
    Jaeger, Simon
    Reinisch, Walter
    Schwab, Matthias
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1294 - 1301
  • [42] Simultaneous quantification of isoniazid, rifampicin, ethambutol and pyrazinamide by liquid chromatography / tandem mass spectrometry
    Prahl, Julie B.
    Lundqvist, Marika
    Bahl, Justyna M. C.
    Johansen, Isik S.
    Andersen, Ase B.
    Frimodt-Moller, Niels
    Cohen, Arieh S.
    APMIS, 2016, 124 (11) : 1004 - 1015
  • [43] Simultaneous Quantification of 17 Cannabinoids in Cannabis Inflorescence by Liquid Chromatography-Mass Spectrometry
    Hewavitharana, Amitha K.
    Gloerfelt-Tarp, Francine
    Nolan, Matthew
    Barkla, Bronwyn J.
    Purdy, Sarah
    Kretzschmar, Tobias
    SEPARATIONS, 2022, 9 (04)
  • [44] Simultaneous quantification of carbamate insecticides in human plasma by liquid chromatography/tandem mass spectrometry
    Mostafa, Ahmed
    Medley, Gregory
    Roberts, Darren M.
    Mohamed, Mosaad Sayed
    Elshanawani, Abdalla A.
    Roberts, Michael S.
    Liu, Xin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2234 - 2238
  • [45] Application of liquid chromatography tandem mass spectrometry for the simultaneous quantification of multiple non-opioid drugs in human plasma
    Kwang-Youl Kim
    Ju-Hee Kang
    Cheol-Woo Kim
    Moonsuk Nam
    Molecular & Cellular Toxicology, 2011, 7 : 185 - 189
  • [46] Simultaneous quantification of multiple classes of phenolic compounds in blood plasma by liquid chromatography-electrospray tandem mass spectrometry
    Chang, Hong
    Wan, Yi
    Naile, Jonathan
    Zhang, Xiaowei
    Wiseman, Steve
    Hecker, Markus
    Lam, Michael H. W.
    Giesy, John P.
    Jones, Paul D.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (04) : 506 - 513
  • [47] Application of liquid chromatography tandem mass spectrometry for the simultaneous quantification of multiple non-opioid drugs in human plasma
    Kim, Kwang-Youl
    Kang, Ju-Hee
    Kim, Cheol-Woo
    Nam, Moonsuk
    MOLECULAR & CELLULAR TOXICOLOGY, 2011, 7 (02) : 185 - 189
  • [48] Development and Validation of the First Liquid Chromatography-Tandem Mass Spectrometry Assay for Simultaneous Quantification of Multiple Antiretrovirals in Meconium
    Himes, Sarah K.
    Scheidweiler, Karl B.
    Tassiopoulos, Katherine
    Kacanek, Deborah
    Hazra, Rohan
    Rich, Kenneth
    Huestis, Marilyn A.
    ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1896 - 1904
  • [49] The use of chemical cross-linking and mass spectrometry to elucidate the tertiary conformation of lipid-bound apolipoprotein A-I
    Thomas, Michael J.
    Bhat, Shaila
    Sorci-Thomas, Mary. G.
    CURRENT OPINION IN LIPIDOLOGY, 2006, 17 (03) : 214 - 220
  • [50] B vitamin quantification in lentil seed tissues using ultra-performance liquid chromatography-selected reaction monitoring mass spectrometry
    Marshall, Jeremy
    Vargas, Ana
    Bett, Kirstin
    FOOD CHEMISTRY, 2024, 430