Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography-Multiple-Reaction-Monitoring Mass Spectrometry

被引:134
|
作者
Agger, Sean A. [1 ]
Marney, Luke C. [1 ]
Hoofnagle, Andrew N. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Lab Med, Seattle, WA 98195 USA
关键词
PEPTIDE IMMUNOAFFINITY ENRICHMENT; QUANTITATION; PROTEIN; PROTEOMICS; BIOMARKER; SERUM; RISK; LIPOPROTEINS; MORTALITY; STANDARDS;
D O I
10.1373/clinchem.2010.152264
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: If liquid-chromatography-multiple-reaction-monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed amultiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS: We used Peptide Atlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS: We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 x immunoassay - 36.6; S-x ' y = 10.3 for apoA-I and LC-MRM/MS = 1.21 x immunoassay + 7.0; S-x ' y = 7.9 for apoB). CONCLUSIONS: Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:1804 / 1813
页数:10
相关论文
共 50 条
  • [21] Effects of the Iowa and Milano Mutations on Apolipoprotein A-I Structure and Dynamics Determined by Hydrogen Exchange and Mass Spectrometry
    Chetty, Palaniappan Sevugan
    Ohshiro, Maki
    Saito, Hiroyuki
    Dhanasekaran, Padmaja
    Lund-Katz, Sissel
    Mayne, Leland
    Englander, Walter
    Phillips, Michael C.
    BIOCHEMISTRY, 2012, 51 (44) : 8993 - 9001
  • [22] The spatial organization of apolipoprotein A-I on the edge of discoidal high density lipoprotein particles - A mass spectrometry study
    Davidson, WS
    Hilliard, GM
    JOURNAL OF BIOLOGICAL CHEMISTRY, 2003, 278 (29) : 27199 - 27207
  • [23] Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring
    Gergov, M
    Ojanperä, I
    Vuori, E
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (01): : 41 - 53
  • [24] CHARACTERIZATION OF HUMAN APOLIPOPROTEIN A-I BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SCHWANDT, P
    RICHTER, WO
    HEINEMANN, V
    WEISWEILER, P
    JOURNAL OF CHROMATOGRAPHY, 1985, 345 (01): : 145 - 149
  • [25] Methods for Peptide and Protein Quantitation by Liquid Chromatography-Multiple Reaction Monitoring Mass Spectrometry
    Zhang, Haixia
    Liu, Qinfeng
    Zimmerman, Lisa J.
    Ham, Amy-Joan L.
    Slebos, Robbert J. C.
    Rahman, Jamshedur
    Kikuchi, Takefume
    Massion, Pierre P.
    Carbone, David P.
    Billheimer, Dean
    Liebler, Daniel C.
    MOLECULAR & CELLULAR PROTEOMICS, 2011, 10 (06)
  • [26] Multiple-Reaction Monitoring Liquid Chromatography Mass Spectrometry for Monosaccharide Compositional Analysis of Glycoproteins
    Hammad, Loubna A.
    Saleh, Marwa M.
    Novotny, Milos V.
    Mechref, Yehia
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (06) : 1224 - 1234
  • [27] Quality Assessment of Insamyangpye Decoction by Liquid Chromatography Tandem Mass Spectrometry Multiple Reaction Monitoring
    Seo, Chang-Seob
    Lee, Mee-Young
    PROCESSES, 2021, 9 (05)
  • [28] SIMULTANEOUS QUANTIFICATION BY DOUBLE ROCKET IMMUNOELECTROPHORESIS OF APOLIPOPROTEIN-A-I AND APOLIPOPROTEIN-B-1 IN BLOOD SPOTTED ON FILTER-PAPER
    MICIC, S
    ARENDS, J
    NORGAARDPEDERSEN, B
    CHRISTOFFERSEN, K
    ANDERSEN, GE
    CLINICAL CHEMISTRY, 1988, 34 (12) : 2452 - 2455
  • [29] Automated reaction monitoring using liquid chromatography-mass spectrometry
    Alton, Dominick J.
    Dymm, Braydon L.
    Smalley, Melanie M.
    Basal, Lina A.
    Evans, Kendra R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [30] Quantification of Bovine Milk Oligosaccharides Using Liquid Chromatography-Selected Reaction Monitoring-Mass Spectrometry
    Fong, Bertram
    Ma, Kevin
    McJarrow, Paul
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (18) : 9788 - 9795