Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography-Multiple-Reaction-Monitoring Mass Spectrometry

被引:134
|
作者
Agger, Sean A. [1 ]
Marney, Luke C. [1 ]
Hoofnagle, Andrew N. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Lab Med, Seattle, WA 98195 USA
关键词
PEPTIDE IMMUNOAFFINITY ENRICHMENT; QUANTITATION; PROTEIN; PROTEOMICS; BIOMARKER; SERUM; RISK; LIPOPROTEINS; MORTALITY; STANDARDS;
D O I
10.1373/clinchem.2010.152264
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: If liquid-chromatography-multiple-reaction-monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed amultiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS: We used Peptide Atlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS: We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 x immunoassay - 36.6; S-x ' y = 10.3 for apoA-I and LC-MRM/MS = 1.21 x immunoassay + 7.0; S-x ' y = 7.9 for apoB). CONCLUSIONS: Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:1804 / 1813
页数:10
相关论文
共 50 条
  • [31] A rapid and sensitive method for the quantification of ganciclovirin plasma using liquid chromatography/selected reaction monitoring/mass spectrometry
    Xu, KY
    Lanuti, M
    Lambright, ES
    Force, SD
    Albelda, SM
    Blair, IA
    BIOMEDICAL CHROMATOGRAPHY, 2000, 14 (02) : 93 - 98
  • [32] Determination of Menadione by Liquid Chromatography-Tandem Mass Spectrometry Using Pseudo Multiple Reaction Monitoring
    Kamao, Maya
    Hirota, Yoshihisa
    Suhara, Yoshitomo
    Tsugawa, Naoko
    Nakagawa, Kimie
    Okano, Toshio
    Hasegawa, Hiroshi
    ANALYTICAL SCIENCES, 2017, 33 (07) : 863 - 867
  • [33] Determination of Menadione by Liquid Chromatography-Tandem Mass Spectrometry Using Pseudo Multiple Reaction Monitoring
    Maya Kamao
    Yoshihisa Hirota
    Yoshitomo Suhara
    Naoko Tsugawa
    Kimie Nakagawa
    Toshio Okano
    Hiroshi Hasegawa
    Analytical Sciences, 2017, 33 : 863 - 867
  • [34] CTP synthetase activity assay by liquid chromatography tandem mass spectrometry in the multiple reaction monitoring mode
    Boschat, Anne-Claire
    Minet, Norbert
    Martin, Emmanuel
    Barouki, Robert
    Latour, Sylvain
    Sanquer, Sylvia
    JOURNAL OF MASS SPECTROMETRY, 2019, 54 (11): : 885 - 893
  • [35] TRACES: A Lightweight Browser for Liquid Chromatography-Multiple Reaction Monitoring-Mass Spectrometry Chromatograms
    Kita, Yoshihiro
    Tokuoka, Suzumi M.
    Oda, Yoshiya
    Shimizu, Takao
    METABOLITES, 2022, 12 (04)
  • [36] Multiplexed immunoprecipitation-liquid chromatography-multiple reaction monitoring mass spectrometry quantification of protein expression and phosphorylation for breast cancer biomarkers
    Chen, Yi
    Britton, David J.
    Wood, Elizabeth R.
    Pike, Ian
    Koomen, John M.
    CANCER RESEARCH, 2012, 72
  • [37] Microfluidics-based liquid chromatography/mass spectrometry multiple reaction monitoring approach for the relative quantification of Burkholderia cenocepacia secreted virulence factors
    Depluverez, Sofie
    Daled, Simon
    De Waele, Stijn
    Planckaert, Soren
    Schoovaerts, Jolien
    Deforce, Dieter
    Devreese, Bart
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (06) : 469 - 479
  • [38] Absolute quantification of podocin, a potential biomarker of glomerular injury in human urine, by liquid chromatography-multiple reaction monitoring cubed mass spectrometry
    Simon, Romain
    Lemoine, Jerome
    Fonbonne, Catherine
    Jaffuel, Aurore
    Leonard, Jean-Francois
    Gautier, Jean-Charles
    Pasquier, Olivier
    Salvador, Arnaud
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 94 : 84 - 91
  • [39] Quantification of biomarker expression, phosphorylation, and mutation in cancer using TMT labeling prior to liquid chromatography-multiple reaction monitoring mass spectrometry
    Chen, Yi
    Britton, David J.
    Paraiso, Kim
    Fedorenko, Inna
    Wood, Elizabeth R.
    Magliocco, Anthony
    Sondak, Vernon K.
    Smalley, Keiran
    Pike, Ian
    Koomen, John M.
    CANCER RESEARCH, 2014, 74 (19)
  • [40] Simultaneous quantification of amiloride and hydrochlorothiazide in human plasma by liquid chromatography–tandem mass spectrometry
    Jaivik V.Shah
    Priyanka A.Shah
    Mallika Sanyal
    Pranav S.Shrivastav
    Journal of Pharmaceutical Analysis, 2017, 7 (05) : 288 - 296