Measurement and detailed simulation of the Modulation Transfer Function of the Medipix2

被引:10
|
作者
Bartl, Peter [1 ]
Korn, Alexander [1 ]
Michel, Thilo [1 ]
Anton, Gisela [1 ]
机构
[1] Univ Erlangen Nurnberg, D-91058 Erlangen, Germany
关键词
MTF; pixel detector; edge-method; low frequency drop; Medipix2;
D O I
10.1016/j.nima.2008.03.081
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Modulation Transfer Function (MTF) is an important quality characteristic for the description of the spatial resolution of imaging systems. For X-ray detectors, like the Medipix2, it depends for instance on the pixel size and the incident spectrum. The detection of single photons in the Medipix2 is additionally influenced by the lower energy threshold. The dependency of the MTF on this threshold and on the incident spectrum has been evaluated by simulations and measurements. By choosing an adequate threshold, the so-called low frequency drop can be suppressed or the spatial resolution in general is influenced. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 50 条
  • [31] Using the Medipix2 detector for photon counting computed tomography
    Niederloehner, Daniel
    Nachtrab, Frank
    Michel, Thilo
    Anton, Gisela
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2327 - 2331
  • [32] An interface board for the control and data acquisition of the Medipix2 chip
    Bello, DS
    van Beuzekom, M
    Jansweijer, P
    Verkooijen, H
    Visschers, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 164 - 170
  • [33] Evolving the Medipix2 technology for use as an active space radiation dosimeter
    Pinsky, L.
    Chancellor, J.
    Minthaka, D.
    2008 IEEE AEROSPACE CONFERENCE, VOLS 1-9, 2008, : 334 - 341
  • [34] Medisoft 4: A software procedure for the control of the Medipix2 readout chip
    Bertolucci, E
    Maiorino, M
    Mettivier, G
    Montesi, MC
    Russo, P
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 714 - 718
  • [35] How good is better? A comparison between the Medipix1 and the Medipix2 chip using mammographic phantoms
    Pfeiffer, KFG
    Giersch, J
    Anton, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 246 - 250
  • [36] Optically sensitive MCP image tube with a Medipix2 ASIC readout
    Vallerga, John
    McPhate, Jason
    Tremsin, Anton
    Siegmund, Oswald
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY III, 2008, 7021
  • [37] USB Lite-Miniaturized readout interface for Medipix2 detector
    Vykydal, Zdenek
    Jakubek, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S48 - S49
  • [38] Neutron imaging and tomography with Medipix2 and dental micro-roentgenography
    Jakubek, J.
    Granja, C.
    Holy, T.
    Lehmann, E.
    Linhart, V.
    Pospisil, S.
    Rypar, V.
    Uher, J.
    Vacik, J.
    Vavrik, D.
    Vykydal, Z.
    Cevallos, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 205 - 209
  • [39] Optically sensitive Medipix2 detector for adaptive optics wavefront sensing
    Vallerga, J
    McPhate, J
    Tremsin, A
    Siegmund, O
    Mikulec, B
    Clark, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 263 - 269
  • [40] ON THE MEASUREMENT OF TRANSFER MODULATION FUNCTION
    NAZAROV, VB
    ZHURNAL NAUCHNOI I PRIKLADNOI FOTOGRAFII, 1993, 38 (01): : 72 - 74