Measurement and detailed simulation of the Modulation Transfer Function of the Medipix2

被引:10
|
作者
Bartl, Peter [1 ]
Korn, Alexander [1 ]
Michel, Thilo [1 ]
Anton, Gisela [1 ]
机构
[1] Univ Erlangen Nurnberg, D-91058 Erlangen, Germany
关键词
MTF; pixel detector; edge-method; low frequency drop; Medipix2;
D O I
10.1016/j.nima.2008.03.081
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Modulation Transfer Function (MTF) is an important quality characteristic for the description of the spatial resolution of imaging systems. For X-ray detectors, like the Medipix2, it depends for instance on the pixel size and the incident spectrum. The detection of single photons in the Medipix2 is additionally influenced by the lower energy threshold. The dependency of the MTF on this threshold and on the incident spectrum has been evaluated by simulations and measurements. By choosing an adequate threshold, the so-called low frequency drop can be suppressed or the spatial resolution in general is influenced. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 50 条
  • [21] Toward a Medipix2 coded aperture gamma microscope
    Accorsi, R
    Autiero, M
    Celentano, L
    Laccetti, P
    Lanza, RC
    Marotta, M
    Mettivier, G
    Montesi, MC
    Riccio, P
    Roberti, G
    Russo, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2461 - 2464
  • [22] Medipix2: Processing and measurements of GaAs pixel detectors
    Zwerger, Andreas
    Fauler, Alex
    Fiederle, Michael
    Jakobs, Karl
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 23 - 26
  • [23] Medipix2 based CdTe microprobe for dental imaging
    Vykydal, Z.
    Fauler, A.
    Fiederle, M.
    Jakubek, J.
    Svestkova, M.
    Zwerger, A.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [24] Biomedical Imaging with the Medipix2 Semiconductor Detector at UniAndes
    Caicedo, I.
    Avila, C.
    Gomez, B.
    Bula, C.
    Roa, C.
    Sanabria, J.
    IX LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2012, 1423
  • [25] Suitability of the Medipix2 readout-chip for radiological imaging
    Luebke, J.
    Mix, M.
    Procz, S.
    Zwerger, A.
    Fiederle, M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5188 - +
  • [26] New results on a gaseous detector using Medipix2 and Micromegas
    Aarts, A. A. A.
    van der Graaf, H.
    van der Putten, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 205 - 208
  • [27] Digital autoradiography with a Medipix2 hybrid silicon pixel detector
    Mettivier, G
    Montesi, MC
    Russo, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 46 - 50
  • [28] Noiseless direct detection of electrons in Medipix2 for electron microscopy
    Faruqi, AR
    Henderson, R
    Tlustos, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 160 - 163
  • [29] Real-time in-vivo μ-imaging with Medipix2
    Dammer, J.
    Frallicciardi, P. M.
    Jakubek, J.
    Jakubek, M.
    Pospisil, S.
    Prenerova, E.
    Vavrik, D.
    Volter, L.
    Weyda, F.
    Zemek, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 205 - 207
  • [30] Characterisation of a GaAs(Cr) Medipix2 hybrid pixel detector
    Tlustos, Lukas
    Shelkov, Georgy
    Tolbanov, Oleg P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S103 - S107