USB Lite-Miniaturized readout interface for Medipix2 detector

被引:28
|
作者
Vykydal, Zdenek [1 ]
Jakubek, Jan [1 ]
机构
[1] Czech Tech Univ, Inst Expt & Appl Phys, CZ-12800 Prague 2, Czech Republic
关键词
Medipix; X-ray imaging; Data acquisition; USB interface; Spectroscopy;
D O I
10.1016/j.nima.2010.06.118
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nowadays, the Medipix2 detector is widely used in many different fields of applications and for some of them the size of the system becomes the critical issue. Therefore we manufactured the miniaturized version of currently used USB interface accommodating the Medipix2 chip on the same printed circuit board as the readout electronics. The dimensions of the whole device are 15 x 60 mm(2) (25% out of it is actually sensitive area). It incorporates all the necessary detector support including the back-side pulse processing circuits and the high voltage source for detector bias (up to 100 V) and it is fully powered from the USB bus. The readout speed of the Medipix2 chip is about 4 fps. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S48 / S49
页数:2
相关论文
共 50 条
  • [1] Signal processor controlled USB2.0 interface for Medipix2 detector
    Platkevic, Michal
    Bocarov, Viktor
    Jakubek, Jan
    Pospisil, Stanislav
    Tichy, Vladimir
    Vykydal, Zdenek
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 245 - 247
  • [2] Medipix2 parallel readout system
    Fanti, V
    Marzeddu, R
    Randaccio, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 171 - 175
  • [3] Medipix2/USB portable radiation camera
    Vykydal, Z.
    Holy, T.
    Jakubek, J.
    Platkevic, M.
    Pospisil, S.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 105 - 107
  • [4] Spectroscopic biomedical imaging with the Medipix2 detector
    T. R. Melzer
    N. J. Cook
    A. P. Butler
    R. Watts
    N. Anderson
    R. Tipples
    P. H. Butler
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 300 - 306
  • [5] Pixelized M-π-n CdTe detector coupled to Medipix2 readout chip
    Kalliopuska, J.
    Nenonen, S.
    Penttila, R.
    Pohjonen, H.
    Tlustos, L.
    Gadda, A.
    Likonen, J.
    Andersson, H.
    Laaksoc, P.
    Vanttajac, I.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [6] Large Area Detector with the Medipix2 Chip
    Canas, Alfonso
    Chmeissani, Mokhtar
    Coll, Ricard
    Glass, David
    Kolstein, Machiel
    Martinez, Ricardo
    Puigdengoles, Carles
    Sanchez, Carlos
    Sancho, Albert
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4501 - 4505
  • [7] Using the Medipix2 detector for energy weighting
    Karg, J
    Niederlöhner, D
    Giersch, J
    Anton, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 306 - 311
  • [8] A portable acquisition system based on USB standardfor the Medipix2 X-ray detector
    Fanti, V
    Marzeddu, R
    Piredda, G
    Randaccio, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3226 - 3228
  • [9] Spectroscopic biomedical imaging with the Medipix2 detector
    Melzer, T. R.
    Cook, N. J.
    Butler, A. P.
    Watts, R.
    Anderson, N.
    Tipples, R.
    Butler, P. H.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (04) : 300 - 306
  • [10] STUDY OF BIOLOGICAL SAMPLES WITH DETECTOR MEDIPIX2
    Dammer, Jiri
    Sopko, Vit
    Jakubek, Jan
    Vavrik, Daniel
    Weyda, Frantisek
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 32 - 36