USB Lite-Miniaturized readout interface for Medipix2 detector

被引:28
|
作者
Vykydal, Zdenek [1 ]
Jakubek, Jan [1 ]
机构
[1] Czech Tech Univ, Inst Expt & Appl Phys, CZ-12800 Prague 2, Czech Republic
关键词
Medipix; X-ray imaging; Data acquisition; USB interface; Spectroscopy;
D O I
10.1016/j.nima.2010.06.118
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nowadays, the Medipix2 detector is widely used in many different fields of applications and for some of them the size of the system becomes the critical issue. Therefore we manufactured the miniaturized version of currently used USB interface accommodating the Medipix2 chip on the same printed circuit board as the readout electronics. The dimensions of the whole device are 15 x 60 mm(2) (25% out of it is actually sensitive area). It incorporates all the necessary detector support including the back-side pulse processing circuits and the high voltage source for detector bias (up to 100 V) and it is fully powered from the USB bus. The readout speed of the Medipix2 chip is about 4 fps. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S48 / S49
页数:2
相关论文
共 50 条
  • [11] GaAs Medipix2 hybrid pixel detector
    Kostamo, Pasi
    Nenonen, Seppo
    Vahanen, Sami
    Tlustos, Lukas
    Frojdh, Christer
    Campbell, Michael
    Zhilyaev, Yuri
    Lipsanen, Harri
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 174 - 177
  • [12] A portable acquisition system based on USB standard for the Medipix2 X-Ray detector
    Fanti, V.
    Marzeddu, R.
    Piredda, G.
    Randaccio, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2578 - 2583
  • [13] Suitability of the Medipix2 readout-chip for radiological imaging
    Luebke, J.
    Mix, M.
    Procz, S.
    Zwerger, A.
    Fiederle, M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5188 - +
  • [14] Optical link based readout system for Medipix2 quad X-ray detector
    Fanti, V.
    Marzeddu, R.
    Randaccio, P.
    Aloisio, A.
    Del Guerra, A.
    Lanconelli, N.
    Mettivier, G.
    Montesi, M. C.
    Pani, R.
    Russo, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 137 - 141
  • [15] Electron imaging with Medipix2 hybrid pixel detector
    McMullan, G.
    Cattermole, D. M.
    Chen, S.
    Henderson, R.
    Llopart, X.
    Summerfield, C.
    Tlustos, L.
    Faruqi, A. R.
    ULTRAMICROSCOPY, 2007, 107 (4-5) : 401 - 413
  • [16] Electron imaging with Medipix2 hybrid pixel detector
    MRC Laboratory of Molecular Biology, Hills Road, Cambridge, CB2 2QH, United Kingdom
    不详
    Ultramicroscopy, 4-5 (401-413):
  • [17] Material reconstruction with the Medipix2 detector with CdTe sensor
    Guni, E.
    Durst, J.
    Michel, T.
    Anton, G.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [18] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Manach, E
    Ponchut, C
    Russo, P
    Tlustos, L
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3394 - 3398
  • [19] Biomedical Imaging with the Medipix2 Semiconductor Detector at UniAndes
    Caicedo, I.
    Avila, C.
    Gomez, B.
    Bula, C.
    Roa, C.
    Sanabria, J.
    IX LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2012, 1423
  • [20] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Maiorino, M
    Manach, E
    Mettivier, G
    Montesi, MC
    Ponchut, C
    Russo, P
    Tlustos, L
    Zwerger, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2379 - 2385