First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip

被引:68
|
作者
Chmeissani, M [1 ]
Frojdh, C
Gal, O
Llopart, X
Ludwig, J
Maiorino, M
Manach, E
Mettivier, G
Montesi, MC
Ponchut, C
Russo, P
Tlustos, L
Zwerger, A
机构
[1] Mid Sweden Univ, Mitthogskolan, Sundsvall, Sweden
[2] CEA, LIST, Saclay, France
[3] CERN, Geneva, Switzerland
[4] Univ Freiburg, Inst Phys, Arbeitsgrp Halbleiterdetektoren, Freiburg, Germany
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[6] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[7] Ist Nazl Fis Nucl, Sez Napoli, I-80126 Naples, Italy
关键词
Me; hybrid detectors; Medipix2;
D O I
10.1109/tns.2004.832324
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present preliminary tests of hybrid pixel detectors consisting of the Medipix2 readout chip bump-bonded to a 1-mm-thick CdTe pixel detector. This room temperature imaging system for single photon counting has been developed within the Medipix2 European Collaboration for various imaging applications with X-rays and gamma rays, including dental radiography, mammography, synchrotron radiation, nuclear medicine, and radiation monitoring in nuclear facilities. The Medipix2 + CdTe hybrid detector features 256 x 256 square pixels, a pitch of 55 mum, a sensitive area of 14 x 14 mm(2). We analyzed the quality of the detector and bump-bonding and the response to nuclear radiation of the first CdTe hybrids. The CdTe pixel detectors, with Pt ohmic contacts, showed an ohmic response when negatively biased up to less than 60 V (electrons collection mode). Tests were also performed in holes collection mode, where a nonresistive behavior was observed above + 15 V. We performed a series of imaging tests at low voltage bias with gamma radioactive sources and with an X-ray tube. Under uniform irradiation, we observed for all detectors the presence of numerous, stable structures in the form of small circles of about 200 mum diameter, with the central pixels showing a reduced counting efficiency with respect to the periphery (in electrons counting regime). Also long filament structures have been observed. Further investigations will reveal whether they are due to an intrinsic detector response (e.g., due to Te inclusions) or to the bump-bonding process.
引用
收藏
页码:2379 / 2385
页数:7
相关论文
共 50 条
  • [1] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Manach, E
    Ponchut, C
    Russo, P
    Tlustos, L
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3394 - 3398
  • [2] Direct growth of CdTe thick films on the Medipix2 pixel detector chip
    Sorgenfrei, R.
    Zwerger, A.
    Disch, C.
    Bachem, K. H.
    Fiederle, M.
    JOURNAL OF APPLIED PHYSICS, 2010, 108 (09)
  • [3] Pixelized M-π-n CdTe detector coupled to Medipix2 readout chip
    Kalliopuska, J.
    Nenonen, S.
    Penttila, R.
    Pohjonen, H.
    Tlustos, L.
    Gadda, A.
    Likonen, J.
    Andersson, H.
    Laaksoc, P.
    Vanttajac, I.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [4] A high resolution, high frame rate detector based on a microchannel plate readout with the Medipix2 counting CMOS pixel chip
    Mikulec, B
    Vallerga, JV
    McPhate, JB
    Tremsin, AS
    Siegmund, OHW
    Clark, AG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1021 - 1026
  • [5] Readout of GEM detectors using the Medipix2 CMOS pixel chip
    Bamberger, A.
    Desch, K.
    Renz, U.
    Titov, M.
    Vlasov, N.
    Wienemann, P.
    Zwerger, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (03): : 361 - 370
  • [6] Characterization of edgeless pixel detectors coupled to Medipix2 readout chip
    Kalliopuska, Juha
    Tlustos, Lukas
    Eranen, Simo
    Virolainen, Tuula
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S32 - S36
  • [7] Using the Medipix2 detector for photon counting computed tomography
    Niederloehner, Daniel
    Nachtrab, Frank
    Michel, Thilo
    Anton, Gisela
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2327 - 2331
  • [8] Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode
    Llopart, X
    Campbell, M
    Dinapoli, R
    Segundo, DS
    Pemigotti, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2279 - 2283
  • [9] GaAs Medipix2 hybrid pixel detector
    Kostamo, Pasi
    Nenonen, Seppo
    Vahanen, Sami
    Tlustos, Lukas
    Frojdh, Christer
    Campbell, Michael
    Zhilyaev, Yuri
    Lipsanen, Harri
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 174 - 177
  • [10] Large Area Detector with the Medipix2 Chip
    Canas, Alfonso
    Chmeissani, Mokhtar
    Coll, Ricard
    Glass, David
    Kolstein, Machiel
    Martinez, Ricardo
    Puigdengoles, Carles
    Sanchez, Carlos
    Sancho, Albert
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4501 - 4505