Direct growth of CdTe thick films on the Medipix2 pixel detector chip

被引:3
|
作者
Sorgenfrei, R. [1 ]
Zwerger, A. [1 ]
Disch, C. [1 ]
Bachem, K. H. [1 ]
Fiederle, M. [1 ]
机构
[1] Univ Freiburg, Freiburger Mat Forschungszentrum, D-79104 Freiburg, Germany
关键词
STABLE BACK CONTACTS; WORK FUNCTION; STABILITY;
D O I
10.1063/1.3492694
中图分类号
O59 [应用物理学];
学科分类号
摘要
Polycrystalline CdTe layers were directly deposited on the Medipix2 readout chip by physical vapor deposition using a Riber molecular beam epitaxy 2300. Sb2Te3 was evaporated as backside contact material, resulting in an M-pi-p diode structure comprising the pixel contact material, the intentionally undoped CdTe, and Sb2Te3. It was possible to achieve x-ray images at 60 kVp. In addition, thermally oxidized Si wafers were coated with a comparable M-pi-p structure grown under identical conditions, to investigate electrical properties of the films. The specific resistance of the layers was found to be 3.85 x 10(8) Omega cm. (C) 2010 American Institute of Physics. [doi:10.1063/1.3492694]
引用
收藏
页数:4
相关论文
共 50 条
  • [1] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Manach, E
    Ponchut, C
    Russo, P
    Tlustos, L
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3394 - 3398
  • [2] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Maiorino, M
    Manach, E
    Mettivier, G
    Montesi, MC
    Ponchut, C
    Russo, P
    Tlustos, L
    Zwerger, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2379 - 2385
  • [3] GaAs Medipix2 hybrid pixel detector
    Kostamo, Pasi
    Nenonen, Seppo
    Vahanen, Sami
    Tlustos, Lukas
    Frojdh, Christer
    Campbell, Michael
    Zhilyaev, Yuri
    Lipsanen, Harri
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 174 - 177
  • [4] Large Area Detector with the Medipix2 Chip
    Canas, Alfonso
    Chmeissani, Mokhtar
    Coll, Ricard
    Glass, David
    Kolstein, Machiel
    Martinez, Ricardo
    Puigdengoles, Carles
    Sanchez, Carlos
    Sancho, Albert
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4501 - 4505
  • [5] Electron imaging with Medipix2 hybrid pixel detector
    McMullan, G.
    Cattermole, D. M.
    Chen, S.
    Henderson, R.
    Llopart, X.
    Summerfield, C.
    Tlustos, L.
    Faruqi, A. R.
    ULTRAMICROSCOPY, 2007, 107 (4-5) : 401 - 413
  • [6] Material reconstruction with the Medipix2 detector with CdTe sensor
    Guni, E.
    Durst, J.
    Michel, T.
    Anton, G.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [7] Electron imaging with Medipix2 hybrid pixel detector
    MRC Laboratory of Molecular Biology, Hills Road, Cambridge, CB2 2QH, United Kingdom
    不详
    Ultramicroscopy, 4-5 (401-413):
  • [8] Pixelized M-π-n CdTe detector coupled to Medipix2 readout chip
    Kalliopuska, J.
    Nenonen, S.
    Penttila, R.
    Pohjonen, H.
    Tlustos, L.
    Gadda, A.
    Likonen, J.
    Andersson, H.
    Laaksoc, P.
    Vanttajac, I.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [9] Digital autoradiography with a Medipix2 hybrid silicon pixel detector
    Mettivier, G
    Montesi, MC
    Russo, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 46 - 50
  • [10] On the energy response function of a CdTe Medipix2 Hexa detector
    Koenig, Thomas
    Zwerger, Andreas
    Zuber, Marcus
    Schuenke, Patrick
    Nil, Simeon
    Guni, Ewald
    Fauler, Alex
    Fiederle, Michael
    Oelfke, Uwe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S265 - S268