Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode

被引:613
|
作者
Llopart, X [1 ]
Campbell, M
Dinapoli, R
Segundo, DS
Pemigotti, E
机构
[1] CERN, European Org Nucl Res, CH-1211 Geneva 23, Switzerland
[2] NIKHEF, Natl Inst Nucl Phys & High Eneryg Phys, NL-1098 SJ Amsterdam, Netherlands
[3] CERN, European Org Nucl Res, CH-1211 Geneva 23, Switzerland
[4] Univ Pisa, I-56010 Pisa, Italy
[5] Ist Nazl Fis Nucl, Natl Inst Fus Fus, I-56010 Pisa, Italy
关键词
CMOS; medipix; photon counting; pixel; X-rays;
D O I
10.1109/TNS.2002.803788
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Medipix2 chip is a pixel-detector readout chip consisting of 256 x 256 identical elements, each working in single photon counting mode for positive or negative input charge signals. Each pixel cell contains around 500 transistors and occupies a total surface area of 55 mum x 55 mum. A 20-mum wide octagonal opening connects the detector and the preamplifier input via bump bonding. The preamplifier feedback provides compensation for detector leakage current on a pixel by pixel basis. Two identical pulse height discriminators are used to create a pulse if the preamplifier output falls within a defined energy window. These digital pulses are then counted with a 13-b pseudorandom counter. The counter logic, based in a shift register, also behaves as the input-output register for the pixel. Each cell also has an 8-b configuration register which allows masking, test-enabling and 3-b individual threshold adjust for each discriminator. The chip can be configured in serial mode and readout either serially or in parallel. The chip is designed and manufactured in a 6-metal 0.25-mum CMOS technology. First measurements show an electronic pixel noise of 140 e(-) root mean square (rms) and an unadjusted threshold variation around 360 e(-) rms.
引用
收藏
页码:2279 / 2283
页数:5
相关论文
共 19 条
  • [1] Medipix2, a 64k pixel read out chip with 55 μm square elements working in single photon counting mode
    Llopart, X
    Campbell, M
    San Segundo, D
    Pernigotti, E
    Dinapoli, R
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1484 - 1488
  • [2] Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E.
    Llopart, X.
    Tlustos, L.
    Wong, W.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S15 - S18
  • [3] First test measurements of a 64k pixel readout chip working in single photon counting mode
    Llopart, X
    Campbell, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 157 - 163
  • [4] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Manach, E
    Ponchut, C
    Russo, P
    Tlustos, L
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3394 - 3398
  • [5] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Maiorino, M
    Manach, E
    Mettivier, G
    Montesi, MC
    Ponchut, C
    Russo, P
    Tlustos, L
    Zwerger, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2379 - 2385
  • [6] The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E. H. M.
    Llopart, X.
    Tlustos, L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1824 - 1829
  • [7] The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode with Improved Spectrometric Performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E. H. M.
    Llopart, X.
    Tlustos, L.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3557 - 3561
  • [8] Readout chip for a 64 × 64 pixel matrix with 15-bit single photon counting
    Campbell, M.
    Heijne, E.H.M.
    Meddeler, G.
    Pernigotti, E.
    Snoeys, W.
    [J]. IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 751 - 753
  • [9] A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting
    Campbell, M
    Heijne, EHM
    Meddeler, G
    Pernigotti, E
    Snoeys, W
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 751 - 753
  • [10] A prototype pixel readout chip working in single photon counting mode with a novel charge sharing suppression scheme
    Cui, S.
    Wei, W.
    Zhang, J.
    Li, M.
    Li, H.
    Li, Z.
    Jiang, X.
    Zhu, K.
    Liu, P.
    Wang, Z.
    Chen, Y.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (07)