Alumina ceramic implant abutments used for single-tooth replacement:: A prospective 1-to 3-year multicenter study

被引:0
|
作者
Andersson, B [1 ]
Taylor, Å
Lang, BR
Scheller, H
Schärer, P
Sorensen, JA
Tarnow, D
机构
[1] SU Molndal, Specialist Dent Serv, SIM Prosthet Dent, S-43180 Molndal, Sweden
[2] Nobel Biocare, Dept Clin Res, Gothenburg, Sweden
[3] Univ Michigan, Sch Dent, Div Prosthodont, Dept Biol & Mat Sci, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Excellence, Nobel Biocare, Ann Arbor, MI 48109 USA
[5] Johannes Gutenberg Univ Mainz, Dept Prosthodont, D-6500 Mainz, Germany
[6] Univ Zurich, Dept Prosthodont & Dent Mat, Zurich, Switzerland
[7] Oregon Hlth & Sci Univ, Clin Res Ctr, Portland, OR 97201 USA
[8] NYU, Coll Dent, Ashman Dept Implant Dent, New York, NY USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the study was to compare results after 1 and 3 years when single crowns supported by CerAdapt (test) ceramic abutments or CeraOne (control) titanium abutments were loaded. Materials and Methods: The material was divided into two groups: in group A, 69 (34 test, 35 control) abutments/crowns from all involved clinics were followed for 1 year; and in group B, 20 (10 test, 10 control) abutments/crowns from one of the clinics were followed for 3 years. Results: No implant failed, giving a cumulative success rate of 100% for the implants. Two CerAdapt abutments in group A fractured, giving a cumulative success rate of 93% for the CerAdapt and 100% for the CeraOne abutments after 1 year. No abutment failed in group B, giving a cumulative success rate of 100% both for the CerAdapt and the CeraOne abutments between 1 and 3 years. The CerAdapt fractures might have been due to the fact that the abutments were impaired through too-extensive preparation and/or had been exposed to a too-high bending moment. Almost no marginal bone loss was recorded, indicating a stable bone situation both at CerAdapt and CeraOne abutments on single-tooth implants. Healthy conditions, with a relatively stable level of the periimplant mucosa in relation to the abutment/crown, were recorded for soft tissues both at CerAdapt and CeraOne abutments. Both clinicians and patients rated the esthetic result as excellent for practically all cases. Conclusion: The results demonstrate the esthetic possibilities and the safety of single-tooth replacement when accepted treatment concepts are followed and documented components are used. The tested abutments worked well, although the fractured CerAdapt abutments indicate that ceramic abutments are more sensitive to handling procedures than the titanium abutments.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 50 条
  • [41] Computer-Aided Designed/Computer-Assisted Manufactured Composite Resin Versus Ceramic Single-Tooth Restorations: A 3-Year Clinical Study
    Vanoorbeek, Sara
    Vandamme, Katleen
    Lijnen, Inge
    Naert, Ignace
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (03) : 223 - 230
  • [42] Esthetic Outcomes of Single-Tooth Implant-Supported Restorations Using Metal-Ceramic Restorations with Zirconia or Titanium Abutments: A Randomized Controlled Clinical Study
    Baldini, Nicola
    D'Elia, Chiara
    Clementini, Marco
    Carrillo de Albornoz, Ana
    Sanz, Mariano
    De Sanctis, Massimo
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (04) : E59 - E66
  • [43] Prefabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: evaluation of peri-implant tissues and superstructures after 12 months of function
    Nothdurft, Frank
    Pospiech, Peter
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) : 857 - 865
  • [44] Fatigue Resistance of 2 Different CAD/CAM Glass-Ceramic Materials Used for Single-Tooth Implant Crowns
    Cavusoglu, Yeliz
    Sahin, Erdal
    Gurbuz, Riza
    Akca, Kivanc
    IMPLANT DENTISTRY, 2011, 20 (05) : 374 - 378
  • [45] 3-Year Randomized Controlled Prospective Clinical Trial on Different CAD-CAM Implant Abutments
    Ferrari, Marco
    Tricarico, Maria Gabriella
    Cagidiaco, Maria Crysanti
    Vichi, Alessandro
    Gherlone, Enrico Felice
    Zarone, Fernando
    Sorrentino, Roberto
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (06) : 1134 - 1141
  • [46] Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for 2 or more years
    Levine, RA
    Clem, DS
    Wilson, TG
    Higginbottom, F
    Solnit, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (04) : 516 - 520
  • [47] Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study
    Att, W
    Kurun, S
    Gerds, T
    Strub, JR
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02): : 111 - 116
  • [48] Use of short implants (6mm) in a single-tooth replacement: a 5-year follow-up prospective randomized controlled multicenter clinical study
    Rossi, Fabio
    Botticelli, Daniele
    Cesaretti, Gianfranco
    De Santis, Enzo
    Storelli, Stefano
    Lang, Niklaus P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (04) : 458 - 464
  • [49] A prospective clinical evaluation of different single-tooth restoration designs on osseointegrated implants - A 3-year follow-up of Branemark implants
    Wannfors, K
    Smedberg, JI
    CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (06) : 453 - 458
  • [50] Performance of zirconia abutments for implant-supported single-tooth crowns in esthetic areas: a retrospective study up to 12-year follow-up
    Passos, Sheila Pestana
    Linke, Bernie
    Larjava, Hannu
    French, David
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (01) : 47 - 54