Use of short implants (6mm) in a single-tooth replacement: a 5-year follow-up prospective randomized controlled multicenter clinical study

被引:114
|
作者
Rossi, Fabio [1 ]
Botticelli, Daniele [2 ]
Cesaretti, Gianfranco [3 ]
De Santis, Enzo [2 ]
Storelli, Stefano [4 ]
Lang, Niklaus P. [5 ,6 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci, Bologna, Italy
[2] ARDEC, Ariminum Odontol, Rimini, Italy
[3] Univ Med Sci, Fac Dent, Havana, Cuba
[4] Univ Milan, San Paolo Hosp, Unit Implantol & Prosthodont, Dept Hlth Sci,Dent Clin, Milan, Italy
[5] Univ Zurich, Ctr Dent Med, Zurich, Switzerland
[6] Univ Bern, Bern, Switzerland
关键词
dental implants; early loading; implant length; prospective randomized; short implants; SLA surface; SHORT DENTAL IMPLANTS; LIFE TABLE ANALYSIS; POSTERIOR REGION; ITI IMPLANTS; PARTIAL EDENTULISM; SURFACE IMPLANTS; ROUGH-SURFACE; ORAL IMPLANTS; SURVIVAL; OSSEOINTEGRATION;
D O I
10.1111/clr.12564
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo evaluate prospectively clinical and radiographic outcomes of 6- or 10mm-long implants with moderately rough surface (SLA((R))) loaded within 7weeks from installation and supporting single crowns in the posterior regions in the course of 5years of loading. Material and MethodsSixty implants with a moderately rough surface, 30 tests (6mm long, 4.1mm in diameter) and 30 controls (10mm long, 4.1mm in diameter), were placed in posterior regions in 45 patients. After 6weeks, impressions were taken and the implants were restored with a single fixed prosthesis made with gold-palladium alloy and porcelain. Survival rate and marginal bone loss were evaluated yearly. The clinical crown/implant ratio was calculated. ResultsDuring the follow-up period, five implants, four tests and one control, were lost. Of the four test implants, one was lost before loading, two between the 2nd and the 3rd years, and one during the 4th year of the follow-up period. The control implant was lost during the first year of function. Consequently, after 5years of follow-up, a survival rate of 86.7% and 96.7% was observed at the test and control sites, respectively. ConclusionThe results of this study showed that 6-mm-long implants supporting single crowns loaded within 7weeks from installation lose a small amount of marginal bone during 5years of functional loading, similar to that of 10-mm-long implants. However, a higher degree of implant loss was recorded at the short implants, probably due to the fracturing of the surrounding bone.
引用
收藏
页码:458 / 464
页数:7
相关论文
共 50 条
  • [1] A 5-year prospective clinical trial on short implants (6mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading
    Ayna, Mustafa
    Wessing, Bastian
    Gutwald, Ralf
    Neff, Andreas
    Ziebart, Thomas
    Acil, Yahya
    Wiltfang, Joerg
    Guelses, Aydin
    [J]. ODONTOLOGY, 2019, 107 (02) : 244 - 253
  • [2] Marginal Bone Preservation in Single-Tooth Replacement: A 5-Year Prospective Clinical Multicenter Study
    Donati, Mauro
    La Scala, Vincenzo
    Di Raimondo, Rosario
    Speroni, Stefano
    Testi, Massimo
    Berglundh, Tord
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (03) : 425 - 434
  • [5] Prospective Clinical Multicenter Study Evaluating the 5-Year Performance of Zirconia Implants in Single-Tooth Gaps
    Gahlert, Michael
    Kniha, Heinz
    Laval, Sabine
    Gellrich, Nils-Claudius
    Bormann, Kai-Hendrik
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 804 - 811
  • [7] Five-Year Survival of Short Single-Tooth Implants (6 mm): A Randomized Controlled Clinical Trial
    Naenni, N.
    Sahrmann, P.
    Schmidlin, P. R.
    Attin, T.
    Wiedemeier, D. B.
    Sapata, V.
    Hammerle, C. H. F.
    Jung, R. E.
    [J]. JOURNAL OF DENTAL RESEARCH, 2018, 97 (08) : 887 - 892
  • [8] A 5-year prospective clinical trial on short implants (6 mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading
    Mustafa Ayna
    Bastian Wessing
    Ralf Gutwald
    Andreas Neff
    Thomas Ziebart
    Yahya Açil
    Jörg Wiltfang
    Aydin Gülses
    [J]. Odontology, 2019, 107 : 244 - 253
  • [9] Radiographic and clinical evaluation of single-tooth Biolok implants: A 5-year study
    Taylor, RC
    McGlumphy, EA
    Tatakis, DN
    Beck, FM
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (06) : 849 - 854
  • [10] One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study
    Nilsson, Andree
    Johansson, Lars-Ake
    Lindh, Christina
    Ekfeldt, Anders
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 916 - 925