Alumina ceramic implant abutments used for single-tooth replacement:: A prospective 1-to 3-year multicenter study

被引:0
|
作者
Andersson, B [1 ]
Taylor, Å
Lang, BR
Scheller, H
Schärer, P
Sorensen, JA
Tarnow, D
机构
[1] SU Molndal, Specialist Dent Serv, SIM Prosthet Dent, S-43180 Molndal, Sweden
[2] Nobel Biocare, Dept Clin Res, Gothenburg, Sweden
[3] Univ Michigan, Sch Dent, Div Prosthodont, Dept Biol & Mat Sci, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Excellence, Nobel Biocare, Ann Arbor, MI 48109 USA
[5] Johannes Gutenberg Univ Mainz, Dept Prosthodont, D-6500 Mainz, Germany
[6] Univ Zurich, Dept Prosthodont & Dent Mat, Zurich, Switzerland
[7] Oregon Hlth & Sci Univ, Clin Res Ctr, Portland, OR 97201 USA
[8] NYU, Coll Dent, Ashman Dept Implant Dent, New York, NY USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the study was to compare results after 1 and 3 years when single crowns supported by CerAdapt (test) ceramic abutments or CeraOne (control) titanium abutments were loaded. Materials and Methods: The material was divided into two groups: in group A, 69 (34 test, 35 control) abutments/crowns from all involved clinics were followed for 1 year; and in group B, 20 (10 test, 10 control) abutments/crowns from one of the clinics were followed for 3 years. Results: No implant failed, giving a cumulative success rate of 100% for the implants. Two CerAdapt abutments in group A fractured, giving a cumulative success rate of 93% for the CerAdapt and 100% for the CeraOne abutments after 1 year. No abutment failed in group B, giving a cumulative success rate of 100% both for the CerAdapt and the CeraOne abutments between 1 and 3 years. The CerAdapt fractures might have been due to the fact that the abutments were impaired through too-extensive preparation and/or had been exposed to a too-high bending moment. Almost no marginal bone loss was recorded, indicating a stable bone situation both at CerAdapt and CeraOne abutments on single-tooth implants. Healthy conditions, with a relatively stable level of the periimplant mucosa in relation to the abutment/crown, were recorded for soft tissues both at CerAdapt and CeraOne abutments. Both clinicians and patients rated the esthetic result as excellent for practically all cases. Conclusion: The results demonstrate the esthetic possibilities and the safety of single-tooth replacement when accepted treatment concepts are followed and documented components are used. The tested abutments worked well, although the fractured CerAdapt abutments indicate that ceramic abutments are more sensitive to handling procedures than the titanium abutments.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 50 条
  • [31] Prospective Clinical Multicenter Study Evaluating the 5-Year Performance of Zirconia Implants in Single-Tooth Gaps
    Gahlert, Michael
    Kniha, Heinz
    Laval, Sabine
    Gellrich, Nils-Claudius
    Bormann, Kai-Hendrik
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 804 - 811
  • [32] Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function
    Sailer, Irena
    Zembic, Anja
    Jung, Ronald Ernst
    Siegenthaler, David
    Holderegger, Claudia
    Haemmerle, Christoph Hans Franz
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) : 219 - 225
  • [33] A 3-year prospective clinical and radiologic analysis of early loaded maxillary dental implants supporting single-tooth crowns
    Turkyilmaz, Ilser
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (04) : 389 - 390
  • [34] Five-year prospective study of prosthodontic and surgical single-tooth implant treatment in general practices and at a specialist clinic
    Andersson, B
    Odman, P
    Lindvall, AM
    Branemark, PI
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1998, 11 (04) : 351 - 355
  • [35] A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up
    Bormann, Kai-Hendrik
    Gellrich, Nils-Claudius
    Kniha, Heinz
    Schild, Sabine
    Weingart, Dieter
    Gahlert, Michael
    BMC ORAL HEALTH, 2018, 18
  • [36] Marginal Bone Levels and Soft Tissue Conditions Around Single-Tooth Implants with a Scalloped Neck Design: Results of a Prospective 3-Year Study
    Khraisat, Ameen
    Zembic, Anja
    Jung, Ronald E.
    Hammerle, Christoph H. F.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 550 - 555
  • [37] A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up
    Kai-Hendrik Bormann
    Nils-Claudius Gellrich
    Heinz Kniha
    Sabine Schild
    Dieter Weingart
    Michael Gahlert
    BMC Oral Health, 18
  • [38] Single-Tooth Replacement in the Maxillary Esthetic Zone with Immediate Implant Insertion and Definitive Abutment Placement and Provisionalization: 1-Year Results of a Prospective Case Series
    Todescan, Francisco Fernando
    Reis, Isabella Neme Ribeiro dos
    Ruiz, Glaucio Morente
    Spin-Neto, Rubens
    Romito, Giuseppe Alexandre
    Pannuti, Claudio Mendes
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 (01) : E27 - E34
  • [39] Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year
    Kwon, Min-Jung
    Yeo, In-Sung
    Kim, Young-Kyun
    Yi, Yang-Jin
    Yang, Jae-Ho
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (02): : 54 - 57
  • [40] Immediate loading of post-extractive single-tooth implants: a 1-year prospective study
    Cristalli, Maria Paola
    Marini, Roberta
    La Monaca, Gerardo
    Sepe, Claudio
    Tonoli, Federica
    Annibali, Susanna
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1070 - 1079