Optimizing condenser fan control for air-cooled centrifugal chillers

被引:26
|
作者
Yu, F. W. [1 ]
Chan, K. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
关键词
air-cooled chiller; centrifugal compressor; coefficient of performance; electricity consumption;
D O I
10.1016/j.ijthermalsci.2007.07.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current design and operation of air-cooled condensers can cause a significant decrease in chiller performance under part load conditions. This paper demonstrates optimal condenser fan control to improve the coefficient of performance (COP) of air-cooled chillers. This control involves identifying the optimum set point of condensing temperature with the optimized power relationships of the compressors and condenser fans and enhancing the airflow and heat transfer area of the condensers. An example application of this control for an air-cooled centrifugal chiller indicated that the COP could increase by 11.4-237.2%, depending on the operating conditions. Such the increase of the COP results in a reduction of up to 14.1 kWh/m(2), or 27.3% in the annual electricity consumption per unit A/C floor area of chillers, given that the chillers serve an office building requiring an annual cooling energy per unit A/C floor area of 173.3 kWh/m(2). The simulation results of this study will give HVAC engineers a better understanding of how to optimize the design and operation of air-cooled chillers. (C) 2007 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:942 / 953
页数:12
相关论文
共 50 条
  • [21] Air-cooled chillers for hot, dry climates
    Howell, RH
    ASHRAE JOURNAL, 2003, 45 (12) : 38 - +
  • [22] Air-Cooled Chillers For Las Vegas Revisited
    Howell, Ronald H.
    Land, Donald W.
    Land, John M.
    ASHRAE JOURNAL, 2014, 56 (12) : 36 - 44
  • [24] Mechanism of the air temperature rise at the forced draught fan inlets in an air-cooled steam condenser
    He, Weifeng
    Han, Dong
    Yue, Chen
    Pu, Wenhao
    Dai, Yiping
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 355 - 363
  • [26] Life cycle analysis of enhanced condenser features for air-cooled chillers serving air-conditioned buildings
    Yu, FW
    Chan, KT
    BUILDING AND ENVIRONMENT, 2006, 41 (08) : 981 - 991
  • [27] The Effect of Windscreens and Walkways on Air-Cooled Condenser Performance and Fan Blade Dynamic Loading
    Marincowitz, Fredrik S.
    Owen, Michael T. F.
    Muiyser, Jacques
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2021, 143 (10):
  • [28] EFFECT OF WIND ON AIR-COOLED CONDENSER PERFORMANCE
    Maulbetsch, John S.
    DiFilippo, Michael N.
    O'Hagan, Joseph
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 391 - +
  • [29] Wind effects on air-cooled condenser performance
    Borghei, Leila
    Khoshkhoo, Ramin Haghighi
    NEW ASPECTS OF FLUID MECHANICS, HEAT TRANSFER AND ENVIRONMENT, 2010, : 193 - +
  • [30] Optimum setpoint of condensing temperature for air-cooled chillers
    Chan, KT
    Yu, FW
    HVAC&R RESEARCH, 2004, 10 (02): : 113 - 127