Mechanism of the air temperature rise at the forced draught fan inlets in an air-cooled steam condenser

被引:0
|
作者
机构
[1] He, Weifeng
[2] Han, Dong
[3] Yue, Chen
[4] Pu, Wenhao
[5] Dai, Yiping
来源
He, Weifeng | 1600年 / Elsevier Ltd卷 / 71期
关键词
Air temperature - Air-cooled steam condensers - Condenser performance - Diffusion effects - Recirculation rates - Recirculations - Temperature rise - Wind conditions;
D O I
暂无
中图分类号
学科分类号
摘要
Air temperature rise at the forced draught fan inlets always results in a performance reduction of the air-cooled steam condenser (ACSC), and It is significant to investigate the principles of the temperature rise to improve the condenser performance. In the paper, a 2 × 600 MW air-cooled power plant is modeled to investigate the mechanism of the adverse air temperature rise at different wind conditions. In addition to the previous proposed recirculation, It is found that the phenomenon of diffusion effect as well as reverse irrigation is also significant to raise the air temperature at the fan inlets. The average temperature rise as well as the generalized recirculation rate at the inlets of the axial fans grows with the increase of the wind angle at the wind speed of vm = 2 m s-1, while the corresponding peak value arises at the wind angle of β = 135° for other wind speed conditions. © 2014 Elsevier Ltd. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [1] Mechanism of the air temperature rise at the forced draught fan inlets in an air-cooled steam condenser
    He, Weifeng
    Han, Dong
    Yue, Chen
    Pu, Wenhao
    Dai, Yiping
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 355 - 363
  • [2] Numerical investigation of fan performance in a forced draft air-cooled steam condenser
    Bredell, JR
    Kröger, DG
    Thiart, GD
    APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) : 846 - 852
  • [3] Contributors to increased fan inlet temperature at an air-cooled steam condenser
    Owen, Michael
    Kroeger, Detlev G.
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1149 - 1156
  • [4] Sensitivity analysis from the blade angle regulation of the forced draught fans in an air-cooled steam condenser
    He, W. F.
    Zhang, X. K.
    Han, D.
    Gao, L.
    APPLIED THERMAL ENGINEERING, 2017, 123 : 810 - 819
  • [5] THE EFFECT OF HUB CONFIGURATION ON THE PERFORMANCE OF AN AIR-COOLED STEAM CONDENSER FAN
    Meiring, Z.
    van der Spuy, S. J.
    Meyer, C. J.
    PROCEEDINGS OF THE ASME TURBO EXPO 2020: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 1, 2020,
  • [6] Flow distortions at the fan inlet of forced-draught air-cooled heat exchangers
    Duvenhage, K
    Vermeulen, JA
    Meyer, CJ
    Kroger, DG
    APPLIED THERMAL ENGINEERING, 1996, 16 (8-9) : 741 - 752
  • [7] Optimum condenser fan staging for air-cooled chillers
    Yu, FW
    Chan, KT
    APPLIED THERMAL ENGINEERING, 2005, 25 (14-15) : 2204 - 2218
  • [8] Air-cooled condenser
    Phogat, S.S.
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1988, 68 pt 6 : 191 - 195
  • [9] FAN PERFORMANCE IN AIR-COOLED STEAM CONDENSERS
    KROGER, DG
    HEAT RECOVERY SYSTEMS & CHP, 1994, 14 (04): : 391 - 399
  • [10] Influence Investigation from the Forced Draught Fan Mode on the Characteristics of an Air-Cooled Power Plant
    He, Weifeng
    2016 INTERNATIONAL CONFERENCE ON SYSTEM RELIABILITY AND SCIENCE (ICSRS 2016), 2016, : 28 - 32