Mechanism of the air temperature rise at the forced draught fan inlets in an air-cooled steam condenser

被引:0
|
作者
机构
[1] He, Weifeng
[2] Han, Dong
[3] Yue, Chen
[4] Pu, Wenhao
[5] Dai, Yiping
来源
He, Weifeng | 1600年 / Elsevier Ltd卷 / 71期
关键词
Air temperature - Air-cooled steam condensers - Condenser performance - Diffusion effects - Recirculation rates - Recirculations - Temperature rise - Wind conditions;
D O I
暂无
中图分类号
学科分类号
摘要
Air temperature rise at the forced draught fan inlets always results in a performance reduction of the air-cooled steam condenser (ACSC), and It is significant to investigate the principles of the temperature rise to improve the condenser performance. In the paper, a 2 × 600 MW air-cooled power plant is modeled to investigate the mechanism of the adverse air temperature rise at different wind conditions. In addition to the previous proposed recirculation, It is found that the phenomenon of diffusion effect as well as reverse irrigation is also significant to raise the air temperature at the fan inlets. The average temperature rise as well as the generalized recirculation rate at the inlets of the axial fans grows with the increase of the wind angle at the wind speed of vm = 2 m s-1, while the corresponding peak value arises at the wind angle of β = 135° for other wind speed conditions. © 2014 Elsevier Ltd. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [21] Modelling of a condenser-fan control for an air-cooled centrifugal chiller
    Yu, F. W.
    Chan, K. T.
    APPLIED ENERGY, 2007, 84 (11) : 1117 - 1135
  • [22] Modeling steam condensation from steam-air mixture in the inclined tubes of an air-cooled condenser
    Artemov V.I.
    Minko K.B.
    Yan'Kov G.G.
    Thermal Engineering, 2014, 61 (1) : 30 - 40
  • [23] Plenum chamber flow losses in forced draught air-cooled heat exchangers
    Meyer, CJ
    Kroger, DG
    APPLIED THERMAL ENGINEERING, 1998, 18 (9-10) : 875 - 893
  • [24] Performance prediction of an air-cooled steam condenser using UDF method
    He, W. F.
    Dai, Y. P.
    Wang, J. F.
    Li, M. Q.
    Ma, Q. Z.
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1339 - 1350
  • [25] Air side heat transfer characteristics of wavy-finned-tube in a forced draft direct air-cooled steam condenser
    Zhang, Zhaoying
    Yang, Jianguo
    Zhang, Haizhen
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 3 - 8
  • [26] Performance Forecast of Air-Cooled Steam Condenser under Windy Conditions
    Zhang, Xuelei
    Chen, Haiping
    JOURNAL OF ENERGY ENGINEERING, 2016, 142 (01)
  • [27] Performance trends of an air-cooled steam condenser under windy conditions
    van Rooyen, J. A.
    Kroger, D. G.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2008, 130 (02):
  • [28] Performance Assessment of Air-Cooled Steam Condenser with Guide Vane Cascade
    Zhang Xuelei
    Li Yunpeng
    Chen Haiping
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (05) : 993 - 1003
  • [29] Performance Assessment of Air-Cooled Steam Condenser with Guide Vane Cascade
    ZHANG Xuelei
    LI Yunpeng
    CHEN Haiping
    Journal of Thermal Science, 2019, 28 (05) : 993 - 1003
  • [30] Performance Assessment of Air-Cooled Steam Condenser with Guide Vane Cascade
    Xuelei Zhang
    Yunpeng Li
    Haiping Chen
    Journal of Thermal Science, 2019, 28 : 993 - 1003